Zainal Arifin, 1015011085 (2015) Analisis Struktur Gedung POP Hotel Terhadap Beban Gempa Dengan Metode Pushover Analysis. Fakultas Teknik, Universitas Lampung.
|
Text
ABSTRAK.pdf Download (13Kb) | Preview |
|
|
Text
ABSTRACT.pdf Download (12Kb) | Preview |
|
|
Text
COVER DALAM.pdf Download (15Kb) | Preview |
|
|
Text
MENYETUJUI.pdf Download (179Kb) | Preview |
|
|
Text
MENGESAHKAN.pdf Download (228Kb) | Preview |
|
|
Text
SURAT PERNYATAAN.pdf Download (99Kb) | Preview |
|
|
Text
RIWAYAT HIDUP.pdf Download (13Kb) | Preview |
|
|
Text
PERSEMBAHAN.pdf Download (21Kb) | Preview |
|
|
Text
MOTO.pdf Download (17Kb) | Preview |
|
|
Text
SANWACANA.pdf Download (10Kb) | Preview |
|
|
Text
DAFTAR ISI.pdf Download (12Kb) | Preview |
|
|
Text
DAFTAR TABEL.pdf Download (7Kb) | Preview |
|
|
Text
DAFTAR GAMBAR.pdf Download (14Kb) | Preview |
|
|
Text
BAB I.pdf Download (160Kb) | Preview |
|
|
Text
BAB II.pdf Download (629Kb) | Preview |
|
|
Text
BAB III.pdf Download (454Kb) | Preview |
|
![]() |
Text
BAB IV.pdf Restricted to Registered users only Download (2568Kb) |
|
|
Text
BAB V.pdf Download (85Kb) | Preview |
|
|
Text
DAFTAR PUSTAKA.pdf Download (135Kb) | Preview |
Abstrak
Faktanya, peraturan kegempaan Indonesia menunjukkan peningkatan beban gempa rencana. Kondisi ini menyebabkan bangunan bangunan eksisting yang direncanakan dengan peraturan lama membutuhkan usaha perkuatan untuk memastikan kinerjanya berada pada tingkat yang aman. Adanya peningkatan beban gempa yang cukup signifikan dari peraturan gempa terbaru (SNI 1726- 2012) memberikan alasan yang kuat untuk melakukan evaluasi kerawanan dan perencanaan untuk gedung ini. Dalam analisis yang dilakukan, kerawanan bangunan dinilai dari kinerja yang ditunjukkan model bangunan pada analisis non-liniear statik (pushover) berdasarkan beban gempa (SNI 2012). Hasil analisis pushover yang telah menunjukkan bahwa gedung POP Hotel memberikan kinerja damage control, namun dengan sejumlah kecil elemen struktur defisien. Kata kunci : SNI 03-1726-2012, pushover, damage control, beban gempa. In a fact, the development of Indonesian building codes demand higher design earthquake load. This condition generates the need for retrofitting in existing building that was design with older building codes, in purpose to acquire the safe building performance. The significant load increase shown in the latest building code (SNI 03-1726-2012) gives the urgency to perform seismic risk asessment and retrofit design for this building. Seismic risk of the building is determined from the performance level through static non-linear analysis (pushover) based on the design earthquake of the new code (SNI 03-1726-2012). This result means that the damage control performance shown is not valid, unless retrofitting is performed on each of the deficient element. Keywords : SNI 03-1726-2012, pushover, damage control, load of earthquake.
Tipe Karya Ilmiah: | Skripsi |
---|---|
Subyek: | A General Works = Karya Karya Umum Teknologi > Mesin (General). Mesin Sipil (General) Teknologi > Mesin (General). Mesin Sipil (General) Mesin (General). Mesin Sipil (General) |