Puji Siamatun, 111704103 (2015) IMPLEMENTSI RANGKAIAN PENGHITUNG KERAPATAN FLUKS NEUTRON TERKOREKSI N16 RSG-GAS BERBASIS LABVIEW. MIPA, Universitas Lampung.
|
File PDF
ABSTRAK.pdf Download (115Kb) | Preview |
|
|
File PDF
ABSTRACT.pdf Download (82Kb) | Preview |
|
|
File PDF
COVER DALAM.pdf Download (28Kb) | Preview |
|
|
File PDF
PERSETUJUAN.pdf Download (93Kb) | Preview |
|
|
File PDF
PENGESAHAN.pdf Download (107Kb) | Preview |
|
|
File PDF
PERNYATAAN.pdf Download (79Kb) | Preview |
|
|
File PDF
RIWAYAT HIDUP.pdf Download (248Kb) | Preview |
|
|
File PDF
PERSEMBAHAN.pdf Download (97Kb) | Preview |
|
|
File PDF
MOTO.pdf Download (93Kb) | Preview |
|
|
File PDF
KATA PENGHANTAR.pdf Download (241Kb) | Preview |
|
|
File PDF
SANWACANA.pdf Download (140Kb) | Preview |
|
|
File PDF
DAFTAR ISI.pdf Download (95Kb) | Preview |
|
|
File PDF
DAFTAR GAMBAR.pdf Download (12Kb) | Preview |
|
|
File PDF
DAFTAR TABEL.pdf Download (6Kb) | Preview |
|
|
File PDF
BAB I.pdf Download (129Kb) | Preview |
|
|
File PDF
BAB II.pdf Download (1006Kb) | Preview |
|
|
File PDF
BAB III.pdf Download (1044Kb) | Preview |
|
File PDF
BAB IV.pdf Restricted to Hanya pengguna terdaftar Download (1259Kb) |
||
|
File PDF
BAB V.pdf Download (86Kb) | Preview |
|
|
File PDF
DAFTAR PUSTAKA.pdf Download (105Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
IMPLEMENTSI RANGKAIAN PENGHITUNG KERAPATAN FLUKS NEUTRON TERKOREKSI N16 RSG-GAS BERBASIS LABVIEW Telah dilakukan penghitungan sinyal N16 terkoreksi (ϕN16-corr) untuk mendeteksi kecelakaan reaktifitas daerah daya. Penghitungan sinyal ϕN16-corr melibatkan dua kanal pengukuran, yaitu detektor kerapatan fluks neutron dan detektor laju dosis gamma. Rangkaian penghitung ϕN16-corr terdiri dari trigger amplifier (K), integrator (I), dan summing element (S). Rangkaian penghitung ϕN16-corr di simulasikan menggunakan program LabVIEW. Nilai histerisis yang didapatkan yaitu sebesar 0.01 V, dengan nilai batas 0.94 V dan nilai korreksi = -0.94 mV/s. Nilai selisih antara N16 terkoreksi modul perangkat keras terpasang dengan perangkat lunak adalah sebesar 0.04898 V. Kata kunci : Detektor kerapatan fluks neutron, detektor laju dosis gamma, LabVIEW, scram, sinyal N16 terkoreksi (ϕN16-corr). THE COUNTING CIRCUIT OF IMPLEMENTATION NEUTRON FLUX DENSITY CORRECTED N16 RSG GAS BASED LABVIEW The counting of the corrected N16 signal for detecting the reactivity a power reactor accident has been done. N16-corr signal calculation involves two measurement channels, namely detector of neutron flux density and the detector of gamma dose rate. The series of counters for φN16-corr consists of trigger amplifier (K), integrator (I), and a summing element (S). The series of counter φN16-corr simulated using LabVIEW program.Hysteresis value obtained is equal to 0.01 V, with a limit value of 0.94 V and the correction value = -9.4 mV/s. Corrected value of the difference between the N16 hardware modules installed with softwere is equal to 0.04898 V. Keywords: Detector ofneutron flux density, detector of gamma dose rate, LabVIEW, scram, N16 corrected signal (φN16-corr).
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | |
Program Studi: | FAKULTAS MIPA > Prodi Fisika |
Pengguna Deposit: | 6695622 . Digilib |
Date Deposited: | 29 Dec 2015 07:04 |
Terakhir diubah: | 29 Dec 2015 07:04 |
URI: | http://digilib.unila.ac.id/id/eprint/16363 |
Actions (login required)
Lihat Karya Akhir |