ANALISIS SINYAL ULTRASONIK MENGGUNAKAN WINDOWING

REZA NAUFAL LIAWAN , 1115031075 (2016) ANALISIS SINYAL ULTRASONIK MENGGUNAKAN WINDOWING. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
Text
ABSTRAK (ABSTRACT).pdf

Download (218kB) | Preview
[img] Text
SKRIPSI FULL.pdf
Restricted to Registered users only

Download (1MB)
[img]
Preview
Text
SKRIPSI TANPA BAB PEMBAHASAN.pdf

Download (1MB) | Preview

Abstract

ABSTRAK Noise yang terkandung pada sinyal ultrasonik rekaman suara lumba-lumba menyebabkan hasil rekaman(sinyal informasi) tidak sesuai dengan harapan. Salah satu upaya untuk meminimalisir noise tersebut adalah dengan menerapkan teknik windowing. Dalam analisis ini, proses pencuplikan atau perngambilan data sample dilakukan pada software Wavelab 6 guna mempermudah analisis berikutnya pada software Matlab. Teknik windowing yang digunakan adalah Hamming dan Hanning window karena windowing ini mampu memberikan performa yang lebih baik. Selain meminimalisasi noise, tujuan dari penerapan windowing ini adalah untuk mengembalikan sinyal yang discontinue sehingga menjadi sinyal yang continue serta untuk mengurangi kebocoran spektral yang terjadi. Hasil penelitian diperoleh nilai SNR (Signal to Noise Ratio) saat penerapan windowing Hanning lebih besar dibandingkan dengan Hamming, yaitu: 4,8064 untuk rata-rata SNR windowing Hanning dan 4,4823 untuk windowing Hamming. Sehingga dapat disimpulkan bahwa dengan windowing Hanning memberikan performa dan kualitas sinyal yang lebih baik. Kata kunci : Sinyal Ultrasonik, Windowing Hamming, Hanning, SNR (Signal to Noise Ratio) ABSTRACT Noises was in ultrasonic signal of dolphin sounds recording made the information signal was not as the expectation. One of methods to reduce these noises is applying of window techniques. In this paper, data samples were taken by using of Wavelab 6 software to make analyzing on Matlab software will be easier. Window techniques which were used are Hamming and Hanning window cause these windows will give the performance is better. Moreover, the purpose of window application is to make the discontinue signal to become continue signal and to reduce of spectral leakage. The results show that rate of SNR (Signal to Noise Ratio) when Hanning window was applied is better than Hamming’s. It is 4,8064 for Hanning window and 4,4823 for Hamming. So, by using of Hanning window has given the performance and quality signal will be better. Key words: Ultrasonic Signal, Hamming window, Hanning window, SNR (Signal to Noise Ratio)

Item Type: Other
Subjects: Teknologi > Teknik Elektro. Rekayasa elektronik Nuklir
Teknologi > Teknik Elektro. Rekayasa elektronik Nuklir
Divisions: Fakultas Teknik > Prodi Teknik Elektro
Depositing User: 5845975 . Digilib
Date Deposited: 16 Aug 2016 08:46
Last Modified: 16 Aug 2016 08:46
URI: http://digilib.unila.ac.id/id/eprint/23457

Actions (login required)

View Item View Item