Telah dilakukan penelitian untuk mendesain dan membuat simulator elektrokardiografi (EKG) dengan memanfaatkan sound card komputer. Simulator dibangun dari hasil konversi sinyal digital kelistrikan jantung menjadi sinyal analog. Sampel sinyal jantung diambil dari database PhysioNet berupa data matriks (.txt). Database sinyal jantung meliputi MIT-BIH Arrythmia Database (mitdb), MIT-BIH Normal Sinus Rhytm Database (nsrdb), MIT-BIH ST Change Database (stdb), MITBIH Supraventricular Database (svdb), dan MIT-BIH Long Term Database (ltdb). Data format txt dikonversi menjadi audio wav dengan frekuensi sampling 1000 Hz dan 8000 Hz. File digital audio format (.wav) dikonversi menjadi sinyal analog. Tegangan yang dihasilkan masing-masing sampel analog sebesar 5 mV. Hasil penelitian dianalisis secara kualitatif dan kuantitatif dengan membandingkan grid interval sampel analog terhadap sampel digital. Sinyal analog jantung ditampilkan pada osiloskop dengan menggunakan kabel audio mono dan potensiometer untuk memperkecil tegangan. Kata kunci. Elektrokardiografi, simulator EKG, sound card,. ABSTRACT This conducted the research to design and create an electrocardiography simulator (ECG) by using the computer sound card. Simulator has been built from the conversion of the heart's electrical digital signals into analog signals. The samples taken from the cardiac signals PhysioNet database in data matrix (.txt) form. The heart signal database includes the MIT-BIH arrythmia Database (mitdb), MIT-BIH Normal Sinus Rhythm Database (nsrdb), MIT-BIH ST Change Database (stdb), MIT-BIH Supraventricular Database (svdb), and the MIT-BIH Long Term Database (ltdb). The txt format data converted to wav audio with a sampling frequency of 1000 Hz and 8000 Hz. Digital format audio (.wav) files was converting into an analog signal. The voltage generated of each analog samples at 5 mV. The results were analyzed qualitatively and quantitatively by comparing the grid interval sampled analog to digital samples. Cardiac analog signal displayed on the oscilloscope with mono audio cable and potentiometer to minimize output voltage. Keywords. ECG simulator, electrocardiography, sound card.
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | |
Program Studi: | FAKULTAS MIPA > Prodi Fisika |
Pengguna Deposit: | 1410058 . Digilib |
Date Deposited: | 24 Aug 2016 07:22 |
Terakhir diubah: | 24 Aug 2016 07:22 |
URI: | http://digilib.unila.ac.id/id/eprint/23634 |
Actions (login required)
Lihat Karya Akhir |