AJI PENETRAP RAGA, 1215031008 (2017) SIMULASI DAN ANALISA GELOMBANG HARMONISA MULTILEVEL INVERTER SATU FASA TIPE H-BRIDGE. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.
|
File PDF
ABSTRAK.pdf Download (8Kb) | Preview |
|
File PDF
SKRIPSI FULL.pdf Restricted to Hanya pengguna terdaftar Download (3902Kb) |
||
|
File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf Download (1515Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
ABSTRAK Inverter merupakan rangkaian elektronika daya yang berfungsi mengkonversi listrik Direct Current (DC) menjadi bentuk daya listrik Alternating Current (AC). Inverter pada dasarnya menghasilkan distorsi harmonisa yang cukup besar. Multilevel inverter dapat mengurangi distorsi harmonisa inverter dengan menambah jumlah tingkat inverter. Pada penelitian ini dirancang simulasi multilevel inverter satu fasa dengan 3 stage, 5 stage, dan 7 stage. Output tegangan pada multilevel inverter adalah resultan tegangan dari tiap tingkat inverter penyusunnya. Penambahan tingkat multilevel inverter ini dapat mengurangi Total Harmonic Distortion (THD) sebesar 14.79% pada 3 stage, 8.31% pada 5 stage, dan 6.92% pada 7 stage saat kondisi tanpa beban. Penambahan beban R, RC, dan RL menyebabkan nilai THD bertambah, hal ini disebabkan karakteristik beban yang digunakan merubah bentuk gelombang keluaran yang dihasilkan. Penambahan tingkat inverter pada penambahan beban dapat menurunkan nilai THD yang dihasilkan, namun besarnya nilai THD masih diatas 17%. Metode yang digunakan dalam menghitung THD menggunakan Fast Fourier Transform (FFT). Dengan menggunakan softwere Simulink MATLAB dan Function MATLAB didapatkan koefisien Fourier untuk membandingkan hasil simulasi dan hasil perhitungan nilai THD secara manual. Besarnya error data Simulink MATLAB terhadap analisa manual dengan metode analisis Fourier pada penelitian ini yaitu sebesar 0.11% pada sampel gelombang multilevel inverter 3 stage beban R 100 ohm. Kata Kunci : inverter, multilevel inverter, harmonisa, THD, Fast Fourier Transform ABSTRACT Inverter is a series of power electronics that serves to convert the electricity of Direct Current (DC) into the form of electric power Alternating Current (AC). Inverters basically produce considerable harmonic distortion. Multilevel inverter can reduce inverter harmonic distortion by increasing the number of inverter levels. In this research, multilevel inverter simulation is designed with phase 3 stage, 5 stage, and 7 stage. The output voltage of the multilevel inverter is the resultant voltage of each level of the composing inverter. The addition of multilevel inverter this can reduce Total Harmonic Distortion (THD) as big as 14.79% on 3 stages, 8.31% on 5 stages, and 6.92% on 7 stages during the no-load conditions. The addition of loads R, RC, and RL causes of the THD value to increase, this is due to the load characteristics used to change the resulting of output waveform. The addition of inverter level at the addition of load can reduce the value of THD generated, but the value of THD is still above 17%. The method that is used in calculating the value of THD is Fast Fourier Transform. By using MATLAB Simulink softwere and MATLAB Function we got Fourier coefficient to compare simulation result and THD value calculation result manually. In this research the amount of MATLAB Simulink data error on manual analysis with Fourier analysis method is 0.11% in multilevel inverter wave sample on 3 stage load R 100 ohm. Keywords: inverter, multilevel inverter, harmonic, THD, Fast Fourier Transform
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | > Teknik Elektro. Rekayasa elektronik Nuklir > Teknik Elektro. Rekayasa elektronik Nuklir |
Program Studi: | Fakultas Teknik > Prodi S1-Teknik Elektro |
Pengguna Deposit: | 58115981 . Digilib |
Date Deposited: | 27 Jul 2017 03:37 |
Terakhir diubah: | 27 Jul 2017 03:37 |
URI: | http://digilib.unila.ac.id/id/eprint/27518 |
Actions (login required)
Lihat Karya Akhir |