PROFIL DEPOT AIR MINUM ISI ULANG DAN PENERAPAN ANALISIS TOC PADA PEMERIKSAAN KUALITAS AIR MINUM BERDASARKAN SUMBER AIR YANG DIGUNAKAN DI BANDAR LAMPUNG

Ekantika Gilang Muhamad , 0814051040 (2014) PROFIL DEPOT AIR MINUM ISI ULANG DAN PENERAPAN ANALISIS TOC PADA PEMERIKSAAN KUALITAS AIR MINUM BERDASARKAN SUMBER AIR YANG DIGUNAKAN DI BANDAR LAMPUNG. Fakultas Pertanian, Universitas Lampung.

[img]
Preview
File PDF
ABSTRAK.pdf

Download (9Kb) | Preview
[img]
Preview
File PDF
ABSTRACT.pdf

Download (8Kb) | Preview
[img]
Preview
File PDF
COVER DALAM.pdf

Download (79Kb) | Preview
[img]
Preview
File PDF
HALAMAN PENGESAHAN.pdf

Download (65Kb) | Preview
[img]
Preview
File PDF
HALAMAN PERSETUJUAN.pdf

Download (78Kb) | Preview
[img]
Preview
File PDF
PERNYATAAN.pdf

Download (77Kb) | Preview
[img]
Preview
File PDF
BAB I.pdf

Download (48Kb) | Preview
[img]
Preview
File PDF
BAB II.pdf

Download (135Kb) | Preview
[img]
Preview
File PDF
BAB III.pdf

Download (117Kb) | Preview
[img] File PDF
BAB IV.pdf
Restricted to Hanya pengguna terdaftar

Download (255Kb)
[img]
Preview
File PDF
BAB V.pdf

Download (15Kb) | Preview
[img]
Preview
File PDF
DAFTAR PUSTAKA.pdf

Download (14Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

abstrak bahasa indonesia Penelitian ini bertujuan untuk mengetahui profile depot air minum isi ulang (AMIU) di Kota Bandar Lampung dan mengetahui keterkaitan antara total organic carbon (TOC) dengan parameter wajib pengujian kualitas air minum. Penelitian ini terdiri dari dua tahap yakni survei dan pengambilan sampel untuk diuji di laboratorium. Bentuk survei adalah pengamatan langsung di lapangan dan mengisi kuesioner yang ditujukan kepada beberapa tempat yang memproduksi air minum isi ulang di Bandar Lampung. Pengujian laboratorium terdiri dari pengujian kualitas fisik, kimia, dan mikrobiologi. Pengujian kualitas fisik meliputi pengujian bau, kekeruhan, rasa, suhu, jumlah padatan terlarut (TDS), dan warna. Pengujian kualitas kimia meliputi uji pH, karbon organik total (TOC), karbon anorganik (IC), dan total karbon (TC), dan kualitas mikrobiologi meliputi pengujian cemaran angka lempeng total, dan cemaran coliform. Data dianalisis dengan program SPSS. Penelitian menunjukkan bahwa 86% depot AMIU masih menggunakan teknologi penyulingan standar yang menggunakan beberapa mikrofilter, penyaringan mengunakan pasir silika, dan penyaringan menggunakan karbon aktif sedangkan 14% depot AMIU telah menggunakan teknologi reverse osmosis. Metode sterilisasi yang digunakan untuk menyeterilisasikan air bervariasi yaitu ozonisasi, sinar UV, dan kombinasi ozon dan sinar UV. Semua sampel air dari berbagai sumber air baku yang digunakan depot AMIU di Kota Bandar Lampung menunjukkan semua sampel yang diuji telah memenuhi persyaratan kualitas air minum, akan tetapi masih terdapat beberapa tindakan penyimpangan pada administrasi pemerintahan yang dilakukan oleh pengusaha depo AMIU di Kota Bandar Lampung. besarnya nilai parameter TOC akan diikuti oleh besarnyanya parameter TC dan warna, karena parameter TC dan warna memiliki korelasi positif dengan parameter TOC. Kata Kunci: air minum, jumlah karbon organik. abstract bahasa inggris This study aimed to get a profile depot refill drinking water in Bandar Lampung and determined the relationship between total organic carbon (TOC) with the parameters required to test drinking water. This study was consisted of two stages. The first stage was a survey, and the second stage was test of water samples in the laboratory. The survey form was direct observation in the field and filled a questionnaire which addressed to some places that produce refill drinking water in Bandar Lampung. Laboratory testing was consisted of a sample of the quality testing of physical, chemical, and microbiological. Physical quality testing included testing of odor, turbidity, taste, temperature, total dissolved solid (TDS), and color. Chemical quality testing included test of pH, total organic carbon (TOC), inorganic carbon (IC), and total carbon (TC). For the microbiological quality testing included test contamination of total plate count, and coliform contamination. Data were analyzed with SPSS program. The results showed that86% depot refill drinking water still using standard refining technology that used multiple microfilter and silica sand media filtration and activated carbon while 14% depot refill drinking water been using reverse osmosis technology. All samples of water from various sources on the using of raw water to the depot in the city of Bandar Lampung refill drinking water that showed all the samples tested have met the requirements of drinking water quality, but still acts committed irregularities refill drinking water depots in the city of Bandar Lampung. The high value of the parameter TOC will be followed by high TC and color parameters, because the parameters of color and TC were positively correlated with TOC parameter. Keyword : drinking water, total organic carbon.

Jenis Karya Akhir: Skripsi
Subyek:
Program Studi: Fakultas Pertanian dan Pascasarjana > Prodi Teknologi Hasil Pertanian
Pengguna Deposit: 438714 . Digilib
Date Deposited: 13 Oct 2014 02:46
Terakhir diubah: 13 Oct 2014 02:46
URI: http://digilib.unila.ac.id/id/eprint/3943

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir