Andrie Dwi Setyawan, 0815031038 (2014) MANAJEMEN SISTEM TATA UDARA PADA GEDUNG REKTORAT UNIVERSITAS LAMPUNG. Fakultas Teknik, Universitas Lampung.
|
File PDF
ABSTRACT.pdf Download (85Kb) | Preview |
|
|
File PDF
ABSTRAK.pdf Download (8Kb) | Preview |
|
|
File PDF
COVER DALAM.pdf Download (28Kb) | Preview |
|
|
File PDF
HALAMAN PERSETUJUAN.pdf Download (579Kb) | Preview |
|
|
File PDF
HALAMAN PENGESAHAN.pdf Download (580Kb) | Preview |
|
|
File PDF
PERNYATAAN.pdf Download (358Kb) | Preview |
|
|
File PDF
RIWAYAT HIDUP.pdf Download (146Kb) | Preview |
|
|
File PDF
MOTO.pdf Download (71Kb) | Preview |
|
|
File PDF
PERSEMBAHAN.pdf Download (20Kb) | Preview |
|
|
File PDF
SANWACANA.pdf Download (64Kb) | Preview |
|
|
File PDF
DAFTAR ISI.pdf Download (127Kb) | Preview |
|
|
File PDF
DAFTAR TABEL.pdf Download (49Kb) | Preview |
|
|
File PDF
DAFTAR GAMBAR.pdf Download (9Kb) | Preview |
|
|
File PDF
BAB I.pdf Download (18Kb) | Preview |
|
|
File PDF
BAB II.pdf Download (291Kb) | Preview |
|
|
File PDF
BAB III.pdf Download (138Kb) | Preview |
|
File PDF
BAB IV.pdf Restricted to Hanya pengguna terdaftar Download (1134Kb) |
||
|
File PDF
BAB V.pdf Download (52Kb) | Preview |
|
|
File PDF
DAFTAR PUSTAKA.pdf Download (109Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
abstrak indonesia Sistem tata udara merupakan sistem pengkondisian udara yang berfungsi untuk mengatur tingkat kenyamanan baik suhu maupun kelembaban udaranya. Sistem tata udara pada Gedung Rektorat Universitas Lampung (UNILA) masih terbilang kurang baik, dikarenakan pemakaian AC (Air Conditioner) yang kurang bijak dan tidak sesuai dengan standar operasi pemakaian serta penempatan AC (Air Conditioner) yang salah, sehingga menyebabkan konsumsi energi listrik di Gedung Rektorat UNILA mengalami peningkatan setiap bulannya. Karenanya perlu dilakukan penelitian di Gedung Rektorat UNILA melalui manajemen sistem tata udara, untuk mengetahui besarnya energi listrik yang dikonsumsi untuk sistem tata udara. Nilai Intensitas Konsumsi Energi (IKE) diperoleh sebesar 3.13 kWh/m² per bulan, hasil ini merupakan hasil yang sangat efisien menurut standar Per Men ESDM no.13 tahun 2012 yaitu kurang dari 8.5 kWh/m² per bulan. Selain itu untuk tingkat kenyamanan didapatkan hasil rata-rata 68.18% untuk kelembaban dan 27.4ºC untuk suhu ruangan, nilai ini belum mencapai standar yang ditetapkan oleh SNI 6390-2011 yaitu 55 % hingga 65 % untuk kelembaban dan 24 oC hingga 27 oC untuk suhu. Beban pendinginan dihitung menggunakan metoda Perbedaan Temperatur Ekuivalen Total (TETD/TA) dan didapatkan hasil beban maksimum terjadi pada pukul 16.00 atau pada pukul 4 sore dengan total beban sensibel dan laten sebesar 1087062.53 btu/h. Pemakaian energi AC pada Gedung Rektorat UNILA sebesar 761.4 kWh per hari dengan perbandingan total pemakaian energi gedung sebesar 1006.62 kWh per hari. Secara keseluruhan, AC (Air Conditioner) menyumbang pemakaian energi sebesar 75.63% dari total pemakaian energi pada Gedung Rektorat UNILA. Kata kunci : Beban pendinginan, Gedung Rektorat UNILA, Intensitas Konsumsi Energi, sistem tata udara abstract inggris HVAC (Heating, Ventilation, and Air Conditioning) system is air conditioning system to adjust the comfort level of both the ambient temperature and air humidity. HVAC system in the Rectorate Building of Universitas Lampung (UNILA) still not good, because the use of AC (Air Conditioner) are less wise and not in accordance with standard usage and placement operations AC (Air Conditioner) is not standard, that causing energy consumption in the Rectorate Building of UNILA increase every month. Because that, research was need at Rectorate Building of UNILA through management of the HVAC system, to calculate electrical energy consumption that consumed for air conditioning system. Energy Consumption Intensity (IKE) values obtained of 3.13 kWh/m² per month, this result is a highly efficient results according to Permen ESDM no.13 in 2012 is less than 8.5 kWh/m² per month. In addition to the comfort level of the results obtained average of 68.18% for humidity and 27.4ºC for room temperature, this value has not reached the standards set by SNI 6390-2011 is 55% to 65 % for humidity and 24 oC to 27 oC for tempereture. Cooling load is calculated using the method Total Equivalent Temperature Difference (TETD/TA) and the results obtained maximum load occurs at 16.00 or at 4 pm with a total load of sensible and latent is 1087062.53 btu/h. AC energy consumption in the Rectorate Building of UNILA is 761.4 kWh per day with a ratio of total building energy consumption by 1006.62 kWh per day. Overall, AC (Air Conditioner) Energy consumption accounted for 75.63% of total energy consumption in the Rectorate Building of UNILA. Keywords : Cooling load, Rectorate Building of UNILA, Energy Consumption Intensity, HVAC systems
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | |
Program Studi: | Fakultas Teknik > Prodi S1-Teknik Elektro |
Pengguna Deposit: | UPT Perpustakaan Unila |
Date Deposited: | 17 Nov 2014 06:09 |
Terakhir diubah: | 17 Nov 2014 06:09 |
URI: | http://digilib.unila.ac.id/id/eprint/5356 |
Actions (login required)
Lihat Karya Akhir |