Fitria Ayu Lestari, 1517011036 (2019) STUDI ANALISIS ION LOGAM Hg(II) DENGAN ASAM TANAT SECARA SPEKTROFOTOMETRI ULTRAUNGU-TAMPAK. Fakultas Matematika dan Ilmu Pengetahuan Alam, UNIVERSITAS LAMPUNG.
|
File PDF
ABSTRAK.pdf Download (2427Kb) | Preview |
|
File PDF
SKRIPSI FULL.pdf Restricted to Hanya staf Download (2618Kb) |
||
|
File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf Download (2618Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
Telah dilakukan studi analisis ion logam Hg(II) dengan asam tanat secara spektrofotometri ultraungu-tampak. Studi ini dilakukan untuk mengetahui panjang gelombang maksimum kompleks Hg(II)-asam tanat pada pH optimum, konsentrasi optimum, volume optimum dan waktu kestabilan. Hasil penelitian menunjukan, bahwa panjang gelombang maksimum untuk kompleks Hg(II)-asam tanat adalah 420 nm pada pH 9, dengan perbandingan stoikiometri variasi konsentrasi Hg(II) : asam tanat yaitu 1:4, dengan perbandingan stoikiometri variasi volume Hg(II) : asam tanat 1:1 dan mencapai waktu kestabilan setelah 40 menit. Validasi metode pembentukan kompleks Hg(II)-asam tanat diperoleh nilai r sebesar 0,9995, nilai LoD dan LoQ yang diperoleh sebesar 0,00019 dan 0,00065, nilai pesisi dengan %RSD sebesar 0,8732%, serta nilai akurasi dengan % recovery yang diperoleh yaitu 99,45%. Kata Kunci : Asam Tanat, Merkuri, Kompleks Hg(II)-asam tanat Spektrofotometer Ultaungu-Tampak An analysis of Hg(II) metal ions with tannic acid was carried out by using ultraviolet-visible spectrophotometry. This study was aimed to determine the maximum wavelength of complex Hg(II)-tannic acid at optimum pH, optimum concentration, optimum volume and stabil time. The results showed that the maximum wavelength of complex Hg(II)-tannic acid was 420 nm at pH 9, with stoichiometric concentration of Hg(II) : tannic acid was 1:4, the stoichiometric volume of Hg(II) : tannic acid was 1:1, and the stability time was over 40 minutes. The validation method of complex Hg(II)-tannic acid meets the AOAC acceptance standard. The linearity with the r-value of 0.9995, the LoD and LoQ was obtained 0.00019 and 0.00065 respectively. The precision value with %RSD of 0.8732%, and the accuracy value with the % recovery obtained is 99.45%. Keywords: tannic acid, mercury, Hg(II)-tannic acid complex, ultraviolet-visible spectrophotometer
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | 500 ilmu pengetahuan alam dan matematika > 540 Kimia dan ilmu yang berhubungan |
Program Studi: | FAKULTAS MIPA > Prodi Kimia |
Pengguna Deposit: | UPT . Digilib2 |
Date Deposited: | 29 Mar 2022 13:11 |
Terakhir diubah: | 29 Mar 2022 13:11 |
URI: | http://digilib.unila.ac.id/id/eprint/56725 |
Actions (login required)
Lihat Karya Akhir |