Bangunan memiliki kontribusi besar terhadap konsumsi energi. Air conditioner (AC) adalah faktor terbesar dalam penggunaan energi listrik. Konsep free cooling mempunyai perhatian khusus untuk mengurangi jam operasi dan kapasitas yang dibutuhkan pada sistem pendingin konvensional. Free cooling didapat dengan cara mengumpulkan udara dingin pada malam hari pada penyimpanan energi termal dan melepaskan udara dingin pada siang hari. Phase change material (PCM) adalah contoh media penyimpanan dalam konsep free cooling. PCM memiliki densitas energi yang besar, jarak temperatur penyerapan dan pelepasan yang berdekatan. Parafin adalah PCM yang bersifat tidak korosif, sifat kimia stabil, ketersediannya banyak. Penelitian dilakukan pada 2 model ventilasi dengan ukuran 15cmx15cm yang berisikan PCM berbahan aluminium hollow dan mengondisikan temperatur udara masuk 18oC, 20oC, 22oC dengan laju aliran udara 1m/s, 2m/s, 3m/s untuk mengetahui laju pendingan PCM pada masing-masing percobaan. Hasil penelitian menunjukkan bahwa laju pendinginan PCM terbesar adalah 0,173oC/menit didapat pada temperatur udara masuk 18oC dengan laju udara 3m/s pada ventilasi model 1 diikuti ventilasi model 2 dengan laju pendinginan 0,155oC/menit didapat pada temperatur udara masuk 18oC dengan laju udara 3m/s. Pengaruh geometri ventilasi, penurunan temperatur udara masuk, dan peningkatan laju aliran udara berpengaruh terhadap laju pendinginan PCM. Kata kunci : free cooling, PCM, ventilasi Buildings have a major contribution to energy comsumption. Air conditioner is responsible for most of energy use in buildings. Free cooling of buildings have much attention to reduce the operation hours and capacity of conventional cooling. Free cooling could be provided by collecting natural cold energy during night time in appropriate thermal storage form and this could be retrieved when needed. Phase change materials are storage medium in free cooling applications, because have high energy densities, and absorb and release heat at a narrow temperature range. Paraffin are PCM non corrosives, stable chemical reaction, available from many manufactures. This research use 2 models of ventilations made by hollow aluminium with dimensions 15cm x15cm was filled with PCM and conditioned the temperature inlet 18oC, 20oC, 22oC with velocity of air 1m/s, 2m/s, 3m/s to know cooling rate of PCM. The result show largest of cooling rate of PCM is 0,173oC/min provided on temperature inlet 18oC and velocity of air 3m/s on model ventilation 1 while model 2 ventilation has cooling rate of PCM 0,155oC/min on temperature inlet 18oC and velocity of air 3m/s. effect geometry of ventilation, decrease of temperature inlet and increase velocity of air influence cooling rate of PCM. Keywords: free cooling, PCM, ventilation.

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan)
600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: Fakultas Teknik > Prodi S1-Teknik Mesin
Pengguna Deposit: UPT . Teti Novianti
Date Deposited: 01 Apr 2022 06:02
Terakhir diubah: 01 Apr 2022 06:02
URI: http://digilib.unila.ac.id/id/eprint/57209

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir