PENGARUH VARIASI GEOMETRI SIRIP TIPE SUDUT TERHADAP TEMPERATUR DAN PRESSURE DROP KOLEKTOR PHOTOVOLTAIC THERMAL (PV/T) MENGGUNAKAN METODE CFD

Joko Prasetyo, 1615021017 (2021) PENGARUH VARIASI GEOMETRI SIRIP TIPE SUDUT TERHADAP TEMPERATUR DAN PRESSURE DROP KOLEKTOR PHOTOVOLTAIC THERMAL (PV/T) MENGGUNAKAN METODE CFD. Fakultas Teknik, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
1. ABSTRAK - ABSTRACT - Kak Dan (7).pdf

Download (11Kb) | Preview
[img] File PDF
2. SKRIPSI FULL - Kak Dan (7).pdf
Restricted to Hanya staf

Download (4Mb)
[img]
Preview
File PDF
3. SKRIPSI TANPA BAB PEMBAHASAN - Kak Dan (7).pdf

Download (1340Kb) | Preview

Abstrak

Kolektor Photovoltaic Thermal (PV/T) adalah alat yang digunakan untuk mengkonversi gelombang elektromagnetik menjadi energi listrik. Pancaran sinar matahari yang menghasilkan nilai kalor menyebabkan penurunan efisiensi elektrik dari sebuah kolektor Photovoltaic Thermal (PV/T). Penelitian ini bertujuan untuk mengetahui karakteristik termal dan pressure drop dari kolektor Photovoltaic Thermal (PV/T) dengan metode CFD. Penelitian ini mensimulasikan penambahan sirip pada sistem pendinginan kolektor Photovoltaic Thermal. Variasi besar sudut adalah 15o , 30o dan 45o sedangkan variasi tinggi sirip sebesar 50 mm, 75 mm dan 100 mm. Hasil simulasi menunjukkan bahwa semakin besar sudut dan ketinggian sirip akan meningkatkan pergerakan dan luas area aliran fluida sehingga dapat meningkatkan terjadinya perpindahan panas pada kolektor PV/T. Dengan demikian temperatur permukaan PV/T dapat menjadi lebih rendah. Namun pressure drop yang terjadi semakin tinggi akibat adanya penambahan besar sudut dan ketinggian sirip sehingga akan membutuhkan daya pemompaan fluida yang lebih tinggi. Hasil simulasi juga menunjukkan bahwa temperatur PV/T terendah adalah 34,91 oC yang terjadi pada variasi sudut sirip 45o dan tinggi sirip 100 mm pada kecepatan 4 m/s yang menghasilkan pressure drop sebesar 900,34 Pa. Kata kunci : Photovoltaic Thermal, CFD, Temperatur PV/T, Pressure Drop, Sirip. A Photovoltaic Thermal (PV/T) collector is a device used to convert sunlight into electrical energy. The emission of sunlight also produces heat energy that cause a decrease in the electrical efficiency of a Photovoltaic Thermal (PV/T) collector. This research aims to find out the thermal and pressure drop of Photovoltaic Thermal (PV/T) collectors by using CFD Method. The performances of PV/T collectors are simulated by adding fins underneath the surface to absorb the unused waste heat. The variations of fin geometry are 15o , 30o , and 45o for angle fin and 50 mm, 75 mm, and 100 mm for fin height respectively. The simulation results show that the increase in the fin angle affects the movement of working fluid flow become faster than the other fin angle variations. This may contribute to heat transfer enhancement so that the surface temperature of the PV/T collector become decrease. In other case, the fin height is increased to extend the contact area of heat transfer which attribute to decrease the PV/T surface temperature. On contrary to the thermal performance, the higher fin angle and fin height, the pressure drop will be increased and consequently, the consumption of the power will be increased to moving the fluid as well. The results also indicate that the best temperature is found to be 34,91 oC at 45o , 100 mm, and 4 m/s of angle fin, height fin, and fluid velocity respectively with pressure drop of 900,34 Pa. Keywords: Photovoltaic Thermal, CFD, PV/T Temperature, Pressure Drop, Fin.

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan)
600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: Fakultas Teknik > Prodi S1-Teknik Mesin
Pengguna Deposit: UPT . Dito Nipati
Date Deposited: 17 May 2022 03:48
Terakhir diubah: 17 May 2022 03:48
URI: http://digilib.unila.ac.id/id/eprint/61151

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir