Kurnia Agung Laksono, 1715021011 (2022) OPTIMASI PARAMETER PEMESINAN TERHADAP KEPRESISIAN GEOMETRI ULIR KORTIKAL TI-6Al-4V ELI MENGGUNAKAN METODE TAGUCHI L9. TEKNIK, UNIVERSITAS LAMPUNG.

[img] File PDF
ABSTRAK (ABSTRACT).pdf
Restricted to Hanya pengguna terdaftar

Download (88Kb)
[img] File PDF
SKRIPSI FULL.pdf
Restricted to Hanya staf

Download (2363Kb)
[img] File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf
Restricted to Hanya pengguna terdaftar

Download (1635Kb)

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

ABSTRACT OPTIMIZATION OF MACHINING PARAMETERS TO THE PRECISION OF TI-6Al-4V ELI CORTICAL THREAD GEOMETRY USING THE TAGUCHI METHOD L9 By Kurnia Agung Laksono In orthopedic surgery, an implant is a device that is placed as a bone to support fractures, which can be placed inside or outside the body. Titanium and its alloys are a type of material used in bone implants because they have good biocompatible properties and corrosion resistance. This study aims to find optimal conditions for cutting to the precision of cortical thread geometry. CNC machining is the type of machining chosen in this study and the material used is Ti-6Al-4v ELI. The machining parameters used are spindle rotation of 100, 200, and 300 rpm, while the Depth of Cut is 0.01, 0.02, and 0.03 mm, and the lubricants used are synthetic oil, virgin palm oil, and virgin coconut oil. The precision of thread geometry can be seen through the measurement of thread peak distance error, thread height error and thread angle error using profile projector. In this study, it was shown that the optimal cutting conditions were found in the spindle rotation parameters of 300 rpm, DOC of 0.01 mm and VCO type lubricants, resulting in thread peak distance errors and the smallest thread height errors of 0.002 mm and 0.006 mm. This is inversely proportional to the angular error value, the optimal cutting conditions are found in the spindle rotation parameters of 100 rpm and DOC of 0.01 mm with synthetic oil lubricant types, resulting in angular error values of both α and β values of 0.041° and 0.051°. Similarly, the best thread surface profile was obtained in the use of DOC 0.01 mm, the higher the DOC value, the more defects in the form of cutting residue on the thread surface. Keywords : bone implants, Ti-6Al-4V ELI, precision of thread geometry, optimization

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan)
600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: Fakultas Teknik > Prodi S1-Teknik Mesin
Pengguna Deposit: 2208436386 . Digilib
Date Deposited: 25 Aug 2022 07:48
Terakhir diubah: 25 Aug 2022 07:48
URI: http://digilib.unila.ac.id/id/eprint/65720

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir