ANALISA TOTAL HARMONIC DISTORTION PADA SISTEM TENAGA LISTRIK MENGGUNAKAN ALIRAN DAYA HARMONIK

FEBRIAN , ADAM (2023) ANALISA TOTAL HARMONIC DISTORTION PADA SISTEM TENAGA LISTRIK MENGGUNAKAN ALIRAN DAYA HARMONIK. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
ABSTRAK.pdf

Download (22Kb) | Preview
[img] File PDF
SKRIPSI FULL.pdf
Restricted to Hanya staf

Download (2910Kb) | Minta salinan
[img]
Preview
File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf

Download (2903Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Sistem tenaga listrik harus memiliki keandalan yang baik karena sistem tenaga listrik berperan untuk menyalurkan listrik dari sumber daya ke konsumen. Salah satu Low Voltage Main Distribution Board (LVMDB) pada Pabrik spare-part mobil sering mengalami trip. Terdapat beberapa mesin mekanis yang terhubung ke LVMDB tersebut. Terdapat power factor meter menunjukkan nilai Total Harmonic Distortion (THD) arus sebesar 32,1%. Tujuan dari penelitian ini untuk mengidentifikasi beban penyebab harmonisa dan mereduksi nilai harmonisa pada sistem tenaga listrik pabrik. Hipotesis dari penelitian ini adalah beban non-linier merupakan penyebab harmonisa. Metode analisa pada penelitian ini menggunakan aliran daya harmonik. Pengukuran pada LVMDB menggunakan power quality analyzer menunjukkan nilai THD tegangan pada fasa a 2.47%, fasa b 2.43%, dan fasa c 2.40%. THD arus pada fasa a 25.08%, fasa b 25.38%, dan fasa c 24.74%. Berdasarkan IEEE STD 519-2014, nilai THD tegangan maksimum yaitu 8% dan THD arus maksimum yaitu 15%. Berdasarkan standar tersebut, nilai THD arus pada sistem tenaga listrik melewati batas yang ditentukan. Simulasi sistem tenaga listrik menunjukkan nilai THD arus sebesar 22,07%. Orde harmonisa dominan adalah orde ke-11 dan ke-13. Pemasangan single-tuned filter pada simulasi dapat mereduksi nilai THD arus. Nilai THD arus setelah pemasangan single-tuned filter menjadi 3,74% dimana nilai THD tersebut lebih baik dari sebelum pemasangan filter dan sudah memenuhi standar IEEE 519-2014. Kata kunci: THD, aliran daya harmonik, beban non-linier, single-tuned filter, kualitas daya The electrical power system must have good reliability because the electrical power system plays a role in delivering electricity from power sources to consumers. One of the Low Voltage Main Distribution Boards (LVMDB) at car spare parts factories often experiences trips. There are several mechanical machines connected to the LVMDB. There is a power factor meter showing a Total Harmonic Distortion (THD) current value of 32.1%. The purpose of this study is to identify the load that causes harmonics and reduce the value of harmonics in the factory's electrical power system. The hypothesis of this study is that non-linear loads are the cause of harmonics. The analysis method in this study uses harmonic power flow. Measurements on LVMDB using a power quality analyzer show THD voltage values in phase a 2.47%, phase b 2.43%, and phase c 2.40%. THD current in phase a 25.08%, phase b 25.38%, and phase c 24.74%. Based on IEEE STD 519-2014, the maximum voltage THD value is 8% and the maximum current THD is 15%. Based on these standards, the current THD value in the electrical power system exceeds the specified limit. Electrical power system simulations show a current THD value of 22.07%. The dominant harmonic orders are the 11th and 13th orders. The installation of a single-tuned filter in the simulation can reduce the current THD value. The current THD value after single-tuned filter installation becomes 3.74% where the THD value is better than before filter installation and meets IEEE 519- 2014 standards. Keywords: THD, harmonic load flow, non-linear load, single-tuned filter, power quality

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan)
Program Studi: Fakultas Teknik > Prodi S1-Teknik Elektro
Pengguna Deposit: 2308337443 . Digilib
Date Deposited: 26 Sep 2023 05:15
Terakhir diubah: 26 Sep 2023 05:15
URI: http://digilib.unila.ac.id/id/eprint/75875

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir