ADAM, FARREL ALLDILA MAMBU (2024) ANALISIS STABILITAS TRANSIEN TERHADAP ISLANDING OPERATION PADA SISTEM TENAGA LISTRIK DENGAN HYBRID DISTRIBUTED GENERATION. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.
|
File PDF
File Abstrak Adam Farrel - adam adam.pdf Download (197Kb) | Preview |
|
![]() |
File PDF
Full Skripsi Adam Farrel tanpa lampiran - adam adam.pdf Restricted to Hanya staf Download (3221Kb) | Minta salinan |
|
|
File PDF
Full Skripsi Adam Farrel tanpa pembahasan dan lampiran - adam adam.pdf Download (1877Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
Perkembangan energi terbarukan cukup pesat, dan banyak yang akan membangun pembangkit listrik terbarukan. Transisi energi fosil ke energi terbarukan sangat penting untuk mewujudkan energi yang bersih dan ramah lingkungan. Pada sistem tenaga listrik stabilitas menjadi syarat utama agar sistem tenaga dapat berjalan dengan baik, salah satu masalah stabilitas pada sistem tenaga yaitu stabilitas transien. Dalam penelitian ini, dilakukan analisa stabilitas transien akibat gangguan hubung singkat 3 phasa dengan pembangkit terbarukan yaitu wind turbine dan tenaga air menggunakan kriteria sama luas dan power flow tracing. Studi kasus yang digunakan pada penelitian ini yaitu sistem standar IEEE 13-bus. Dari hasil penelitian menunjukan dengan adanya gangguan hubung singkat pada sistem mengakibatkan islanding operation, dengan single-machine sudut pemutusan kritis rotor generator 1 lebih rendah dibandingkan sudut pemutusan kritis rotor generator 2 yaitu sebesar 94.576 ̊ dan 112.320 ̊, dan dengan adanya wind turbine saat beroperasi multi-machine menunjukan sudut ayunan rotor generator lebih rendah meskipun tidak signifikan, namun dengan wind turbine, losses yang dihasilkan lebih besar dan lebih rentan terhadap gangguan karena terbatasnya daya reaktif dan kurangnya efisiensi daya yang dihasilkan. Kata kunci: Stabilitas, Turbin Angin, Aliran Daya, Kriteria Sama Luas, Islanding Operation, Microgrid. The development of renewable energy is quite rapid, and many will build renewable power plants. The transition from fossil energy to renewable energy is very important to realize clean and environmentally friendly energy. In an electric power system, stability is the main requirement for the power system to run well. One of the stability problems in the power system is transient stability. In this research, transient stability analysis was carried out due to 3-phase short circuit disturbances with renewable generators, namely wind turbines and hydropower using equal area criteria and power flow tracing. The case study used in this research is the IEEE 13- bus standard system. The research results show that the presence of a short circuit in the system results in islanding operation, with a single-machine the critical disconnection angle of generator rotor 1 is lower than the critical disconnection angle of generator 2 rotor, namely 94.576 ̊ and 112.320 ̊, and with the presence of a wind turbine when operating multi -machine shows a lower generator rotor swing angle, although not significant, but with a wind turbine, the losses produced are greater and more susceptible to interference due to limited reactive power and lack of efficiency of the power produced. Keywords: Stability, Wind Turbine, Power Flow, Equals Area Criterion, Islanding Operation, Microgrid.
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | 600 Teknologi (ilmu terapan) 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan |
Program Studi: | Fakultas Teknik > Prodi S1-Teknik Elektro |
Pengguna Deposit: | UPT . Dito Nipati |
Date Deposited: | 18 Feb 2025 07:56 |
Terakhir diubah: | 18 Feb 2025 07:56 |
URI: | http://digilib.unila.ac.id/id/eprint/84326 |
Actions (login required)
![]() |
Lihat Karya Akhir |