ANALISIS KINERJA MOTOR INDUKSI 3 FASA DARI ASPEK BESARAN DAYA DAN EFISIENSI MOTOR DALAM MENGGERAKKAN MESIN (STUDI KASUS PADA MESIN JAW CRUSHER DI PT. ALAM TUNGGAL SEMESTA)

MUHAMMAD , RAYHAN PRAMANA RIZQI (2024) ANALISIS KINERJA MOTOR INDUKSI 3 FASA DARI ASPEK BESARAN DAYA DAN EFISIENSI MOTOR DALAM MENGGERAKKAN MESIN (STUDI KASUS PADA MESIN JAW CRUSHER DI PT. ALAM TUNGGAL SEMESTA). FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
1. ABSTRAK - MUHAMMAD RAYHAN PRAMANA RIZQI.pdf

Download (204Kb) | Preview
[img] File PDF
2. SKRIPSI FULL -MUHAMMAD RAYHAN PRAMANA RIZQI.pdf
Restricted to Hanya staf

Download (3121Kb) | Minta salinan
[img]
Preview
File PDF
3. SKRIPSI TANPA BAB PEMBAHASAN - MUHAMMAD RAYHAN PRAMANA RIZQI.pdf

Download (2157Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Pemecahan batu di dunia konstruksi untuk kebutuhan batu split memerlukan alat yang disebut Crusher, salah satu jenis yang cukup sering digunakan adalah Jaw Crusher. Jaw Crusher di PT. Alam Tunggal Semesta menggunakan motor Induksi 3 Fasa sebagai penggeraknya. Namun, motor induksi juga memiliki beberapa masalah terkait daya, efisiensi, dan torsi yang perlu dipertimbangkan. Dimana pada motor induksi 3 fasa dapat dihitung besaran daya dan efisiensinya agar dapat mengetahui kinerja dari motor induksi tersebut. Motor induksi 3 fasa yang ada di perusahaan tersebut dapat diketahui besaran daya dan efisiensinya dengan cara pengambilan data pengukuran tegangan, arus, dan cosphi input maupun output dari alat Monitoring AC Tester yang telah tersedia di perusahaan dengan cara merekamnya menggunakan kamera handphone ketika motor sedang bekerja. Setelah dilakukan pengambilan data pengukuran tersebut baru dapat dihitung untuk besaran daya dan efisiensinya, lalu dilakukan analisis dari pengukuran dan perhitungan dengan cara membandingkan hasil perhitungan daya dan efisiensi saat motor bekerja dengan spesifikasi yang ada pada nameplate motor. Hasil analisis perhitungan dari efisiensi dan daya saat motor starting didapatkan efisiensi motor sebesar 8.72%- 31.85% dan pada daya yang tertingginya 73KW, sehingga efisiensi motor ketika starting masih dibawah nilai nominal motor yaitu 92% dan untuk dayanya melebihi nilai nominal motor yaitu 37KW. Saat motor tidak ada beban terhitung efisiensi sebesar 82-99% atau didapatkan rata-ratanya 92.75% dan untuk dayanya 8.49-9.74KW, sehingga efisiensi motor saat tidak ada beban sesuai dengan nilai nominal motor dan untuk dayanya dibawah daya nominal motor. Saat ada beban didapatkan perhitungan efisiensi motor sebesar 48-98% atau didapatkan rata-ratanya 78.07% dan dayanya sebesar 6.8-10KW yang menandakan pada saat motor ada beban efisiensi yang didapatkan dibawah nilai nominal motor dan untuk dayanya masih dibawah daya nominal motor. Kata kunci: Kinerja Motor, Jaw Crusher, Motor Induksi 3 fasa, Besaran Daya dan Efisiensi. Stone breaking in the world of construction for split stone needs requires a tool called a crusher, one type that is quite often used is the Jaw Crusher. Jaw Crusher at PT. Alam Tunggal Semesta uses a 3 Phase Induction motor as its driving force. However, induction motors also have some issues regarding power, efficiency, and torque that need to be considered. Where in a 3 phase induction motor the power and efficiency can be calculated so that you can determine the performance of the induction motor. The 3-phase induction motor in the company can determine its power and efficiency by taking voltage, current, and Cosphi input and output measurement data from the AC Tester Monitoring tool that is available in the company by recording it using a cellphone camera while the motor is working. After taking the measurement data, the amount of power and efficiency can be calculated, then an analysis of the measurements and calculations is carried out by comparing the results of the power and efficiency calculations when the motor is working with the specifications on the motor nameplate. The results of the calculation analysis of the efficiency and power when the motor is starting show that the motor efficiency is 8.72% - 31.85% and at the highest power it is 73KW, so that the efficiency of the motor when starting is still below the motor's nominal value, namely 92% and the power exceeds the motor's nominal value, namely 37KW. When the motor has no load, the calculated efficiency is 82-99% or the average is 92.75% and the power is 8.49-9.74KW, so that the efficiency of the motor when there is no load is in accordance with the motor's nominal value and the power is below the motor's nominal power. When there is a load, the calculated motor efficiency is 48-98% or the average is 78.07% and the power is 6.8-10KW, which indicates that when the motor has a load, the efficiency obtained is below the motor's nominal value and the power is still below the motor's nominal power. Keywords: Motor Performance, Jaw Crusher, 3 phase Induction Motor, Power Amount and Efficiency.

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: Fakultas Teknik > Prodi S1-Teknik Elektro
Pengguna Deposit: UPT . Siswanti
Date Deposited: 09 Apr 2025 07:54
Terakhir diubah: 09 Apr 2025 07:54
URI: http://digilib.unila.ac.id/id/eprint/85918

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir