Dona , Eliza (2025) IMPLEMENTASI SEPIC KONVERTER PADA PEMBANGKIT LISTRIK TENAGA PIKOHIDRO (PLTPH) DALAM MEMPERTAHANKAN STABILITAS TEGANGAN KELUARAN MENGGUNAKAN METODE ZIEGLER – NICHOLS. TEKNIK, UNIVERSITAS LAMPUNG .
|
File PDF
ABSTRAK - Dona Eliza.pdf Download (199Kb) | Preview |
|
![]() |
File PDF
FULL SKRIPSI - Dona Eliza.pdf Restricted to Hanya staf Download (3113Kb) | Minta salinan |
|
|
File PDF
FULL SKRIPSI TANPA BAB PEMBAHASAN - Dona Eliza.pdf Download (1638Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
Perubahan aliran air pada Pembangkit Listrik Tenaga Pikohidro (PLTPH) menyebabkan tegangan keluaran generator menjadi berfluktuatif. Untuk mengatasi permasalahan ini, digunakan DC -DC konverter jenis Single-Ended Primary Inductor Converter (SEPIC) yang mampu mengatur tegangan keluaran tetap stabil, baik ketika lebih tinggi maupun lebih rendah dari tegangan masukan. Sistem kontrol loop tertutup diterapkan pada konverter SEPIC konverter untuk menjaga kestabilan tegangan secara real-time melalui umpan balik tegangan. Pengendalian dilakukan menggunakan metode Proportional-Integral-Derivative (PID) dengan penalaan parameter berdasarkan metode Ziegler-Nichols. Hasil implementasi kontrol PID dengan nilai parameter Kp = 12, Ki = 12, dan Kd = 3 memberikan kestabilan sistem yang meningkat dibandingkan tanpa pengendali, dengan rise time selama 0.63 detik dan rata – rata settling time selama 2.90 detik, overshoot maksimum sebesar 5,22%, undershoot maksimum sebesar 7,02%, dan error steady state sebesar 0,155%. Pengujian dilakukan dengan beban lampu DC sebesar 10 Watt, 20 Watt, dan 30 Watt menunjukkan bahwa sistem mampu mempertahankan kestabilan tegangan terhadap perubahan beban. Kata Kunci : Pembangkit Listrik Tenaga Pikohidro, SEPIC Konverter, Kontrol PID Changes in water flow at the Pico Hydro Power Plant (PLTPH) cause the generator output voltage to fluctuate. To address this issue, a DC-DC converter of the Single- Ended Primary Inductor Converter (SEPIC) type is used, which can maintain a stable output voltage, whether it is higher or lower than the input voltage. A closed-loop control system is applied to the SEPIC converter to maintain voltage stability in real- time through voltage feedback. Control is performed using the Proportional-Integral- Derivative (PID) method with parameter tuning based on the Ziegler-Nichols method. The implementation of PID control with parameter values Kp = 12, Ki = 12, and Kd = 3 resulted in improved system stability compared to without a controller, with a rise time of 0.63 seconds and an average settling time of 2. 90 seconds, a maximum overshoot of 5.22%, a maximum undershoot of 7.02%, and a steady-state error of 0.155%. Testing was conducted with DC lamp loads of 10 Watts, 20 Watts, and 30 Watts, showing that the system can maintain voltage stability in response to load changes Keyword :Picohydro Power Plant, SEPIC converter, PID Control
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | 600 Teknologi (ilmu terapan) 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan |
Program Studi: | FAKULTAS TEKNIK (FT) > Prodi S1-Teknik Elektro |
Pengguna Deposit: | . . Yulianti |
Date Deposited: | 20 Oct 2025 04:42 |
Terakhir diubah: | 20 Oct 2025 04:42 |
URI: | http://digilib.unila.ac.id/id/eprint/91490 |
Actions (login required)
![]() |
Lihat Karya Akhir |