?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=%0D%0ASTUDI+PENEMPATAN+KAPASITOR%0D%0AUNTUK+PERBAIKAN+KUALITAS+TEGANGAN+%0D%0ADI+PENYULANG+KANGKUNG+GI+MENGGALA%0D%0A&rft.creator=ACHMAD+TAUFIK+PRABOWO%2C++0915031077&rft.subject=Teknik+Elektro.+Rekayasa+elektronik+Nuklir&rft.description=ABSTRAK%0D%0A%0D%0ADalam+tugas+akhir+ini+alokasi+daya+reaktif+didapat+dengan+menggunakan+metode+pemprograman+linier.+Salah+satu+cara+untuk+memperbaiki+profil+tegangan+adalah+dengan+menempatkan+nilai+kapasitor+yang+optimal+di+lokasi+yang+tepat+pada+sistem+distribusi.%0D%0A%0D%0AProfil+tegangan+sebelum+diinjeksi+daya+reaktif+mengalami+penurunan+pada+bus+4+yakni+bernilai+0.7572+p.u+sampai+bus+akhir+yaitu+bus+191+sebesar+0%2C6037+p.u%2C+profil+tegangan+di+bawah+standar+PLN+yakni+-5%25+dari+tegangan+nominal.%0D%0A%0D%0A+Hasil+dari+simulasi+dengan+kapasitor+bank%2C+terlihat+bahwa+profil+tegangan+sesudah+di+pasang+kapasitor+mengalami+kenaikan+dari+bus+awal+yang+terdapat+beban+yaitu+sebesar+1%2C0048+p.u+dan+sampai+bus+akhir+yaitu+bus+191+profil+tegangan+berada+pada+0.9731+p.u+tegangan+bus+tetap+berada+pada+standar+PLN+yaitu+-5%25.+Dalam+penyulang+Kangkung+ini+kondisi+awal++pembebanan+yaitu+untuk+beban+aktif+sebesar+1%2C408+MW+dan+beban+reaktif+1%2C668+MVar.+Setelah+dilakukan+simulasi+pemasangan+kapasitor+di+bus+2+sampai+13+maka+rugi-rugi+beban+aktif+dan+reaktif+dapat+di+minimalisir+besar+beban+aktif+sampai+0%2C101+MW+dan+beban+reaktif+diminimalisir+sampai+0%2C100+MVar.+%0D%0A%0D%0A%0D%0AKata+kunci+%3A+Jatuh+Tegangan%2C+Kapasitor%2C+Penyulang+Kangkung%0D%0A%0D%0A%0D%0A%0D%0A%0D%0A%0D%0A%0D%0AABSTRACT%0D%0A%0D%0AIn+this+undergraduate+thesis+allocation+of+reactive+power+is+obtained+by+using+linear+programming+method.+One+way+to+improve+the+voltage+profile+is+to+place+the+optimal+capacitor+value+in+the+right+location+in+the+distribution+system.%0D%0A%0D%0AVoltage+profile+before+the+injection+of+reactive+power+decreased+at+bus+4+that+is+worth+0.7572+p.u+until+the+end+of+the+bus+is+a+bus+191+for+0.6037+p.u%2C+PLN+standard+voltage+profile+is+under+-5%25+of+the+nominal+voltage.%0D%0A%0D%0AThe+results+of+simulation+with+a+capacitor+bank%2C+it+shown+that+after+the+installation+of+capacitor+voltage+profile+is+increased+from+the+initial+bus+load+contained+in+the+amount+of+1.0048+pu+and+until+the+end+of+that+bus+191+bus+voltage+profile+is+at+0.9731+pu+bus+voltage+remains+at+PLN+standards+that+-5%25.+In+this+Kangkung+feeder+load+the+initial+condition+is+for+the+active+load+of+1%2C408+MW+and+1%2C668+MVAr+reactive+load.+After+simulating+the+installation+of+capacitors+on+a+bus+2+to+13%2C+the+loss+of+active+and+reactive+load+can+be+minimized+active+load+up+to+0.101+MW+and+reactive+load+up+to+0%2C100+MVAr.%0D%0A%0D%0A%0D%0AKeywords%3A+Voltage+drop%2C+Capasitor%2C+Kangkung+feeder%0D%0A%0D%0A&rft.publisher=FAKULTAS+TEKNIK&rft.date=2016-06-17&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F23540%2F1%2FABSTRAK%2520%2528ABSTRACT%2529.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F23540%2F9%2FSKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F23540%2F10%2FSKRIPSI%2520TANPA%2520BAB%2520PEMBAHASAN.pdf&rft.identifier=++ACHMAD+TAUFIK+PRABOWO%2C+0915031077++(2016)++STUDI+PENEMPATAN+KAPASITOR+UNTUK+PERBAIKAN+KUALITAS+TEGANGAN+DI+PENYULANG+KANGKUNG+GI+MENGGALA.++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F23540%2F