?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=STUDI+ALIRAN+DAYA+TIGA+FASA+DENGAN+PENEMPATAN+STEP+VOLTAGE+REGULATOR+HUBUNG+WYE+PADA+PENYULANG+PAKIS+GI+MENGGALA&rft.creator=FANNY+SIMATUPANG%2C+1115031076&rft.subject=Teknik+Elektro.+Rekayasa+elektronik+Nuklir&rft.description=Panjangnya+saluran+distribusi+menyebabkan+profil+tegangan+yang+rendah.+Untuk+mengatasi+masalah+tersebut%2C+dengan+memasang+Step+Voltage+Regulator+(SVR).+SVR+dapat+dipasang+dengan+menggunakan+hubung+wye+atau+hubung+delta+pada+jaringan+distribusi.+Dalam+hal+ini+SVR+menggunakan+analisis+aliran+daya+tiga+fasa+dengan+hubung+wye.+Pada+sistem+distribusi+Lampung%2C+SVR+tipe+B+yang+digunakan+untuk+pekerjaan+ini+dan+tipe+ini+umumnya+sering+ditemukan.%0D%0A%0D%0AModel+yang+dikembangkan+dan+digunakan+dalam+perangkat+lunak+analisis+aliran+daya+tiga+fasa+pada+bahasa+pemprograman+pyton+berdasarkan+metode+Newton-Raphson.+Pada+jaringan+20+kV%2C+penyulang+Pakis+pada+Gardu+Induk+Menggala+biasa+digunakan+untuk+pengujian+dalam+pengembangan+model.+Penyulang+ini+memikul+beban+dari+tegangan+jatuh+sepanjang+saluran+maka+dari+itu+diperlukan+pemasangan+SVR+untuk+meningkatkan+profil+tegangannya.+Hasil+dari+penelitian+ini+kemudian+dibandingkan+dengan+kasus+yang+sama+dengan+OpenDSS+dari+Electric+Power+Research+Institute.+Beban+setimbang+dan+tak+setimbang+di+pertimbangkan+dalam+penelitian+ini.%0D%0A%0D%0AHasil+menunjukkan+dengan+pemasangan+SVR+%C2%B1+10%25+dapat+memperbaiki+profil+tegangan.+Perbandingan+dengan+OpenDSS+juga+menunjukkan+hasil+yang+sama+dengan+perangkat+lunak+yang+dikembangkan+yaitu+UnilaPF.%0D%0A%0D%0AKata+Kunci+%3A+Step+Voltage+Regulator+(SVR)%2C+Tegangan%2C+UnilaPF%2C+OpenDSS%2C+GI+Menggala.%0D%0A%0D%0A%0D%0A%0D%0AABSTRACT%0D%0A%0D%0AA+long+distribution+feeder+may+experience+poor+voltage+profile.+In+order+to+correct+this+problem%2C+a+step+voltage+regulator+(SVR)+can+be+installed.+SVR+can+be+installed+in+either+Delta+or+Wye+connection+to+the+distribution+network.+This+work+addresses+SVR+with+Wye+connection+model+for+a+three-phase+power+flow+analysis.+Type-B+SVR+is+considered+in+this+work+as+this+type+is+commonly+found+the+distribution+system+in+Lampung+Province.%0D%0AThe+developed+model+is+then+implemented+in+a+three-phase+power+flor+analysis+software+written+in+Python+Programming+Language+based+on+Newton-Raphson+method.+An+actual+20+kV%2C+Pakis+Feeder+of+Menggala+Substation+is+used+to+examine+the+developed+model.+This+feeder+suffers+from+high+voltage+drop+along+the+line+and+hence+installation+of+SVR+should+improve+its+voltage+profile.+Results+are+then+compared+with+similar+case+calculated+by+OpenDSS+of+Electric+Power+Research+Institute.+Both+balanced+and+unbalanced+loads+are+considered+in+this+work.%0D%0AResults+show+that+voltage+profile+is+improved+after+installation+of+SVR+of+about+%C2%B1+10%25.+Comparison+with+OpenDSS+also+reveals+that+the+developed+software+produces+similar+results+with+UnilaPF.%0D%0AKata+Kunci+%3A+Step+Voltage+Regulator+(SVR)%2C+Voltage%2C+UnilaPF%2C+OpenDSS%2CWye%2C+Menggala+Substation.%0D%0A&rft.publisher=UNIVERSITAS+LAMPUNG&rft.date=2016-08-10&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F23739%2F1%2FABSTRAK%2520%2528ABSTRACT%2529.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F23739%2F20%2FSKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F23739%2F19%2FSKRIPSI%2520TANPA%2520BAB%2520PEMBAHASAN.pdf&rft.identifier=++FANNY+SIMATUPANG%2C+1115031076++(2016)+STUDI+ALIRAN+DAYA+TIGA+FASA+DENGAN+PENEMPATAN+STEP+VOLTAGE+REGULATOR+HUBUNG+WYE+PADA+PENYULANG+PAKIS+GI+MENGGALA.++UNIVERSITAS+LAMPUNG%2C+FAKULTAS+TEKNIK.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F23739%2F