?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=MANAJEMEN+SISTEM+TATA+UDARA+PADA+GEDUNG+REKTORAT+UNIVERSITAS+LAMPUNG&rft.creator=Andrie+Dwi+Setyawan%2C+0815031038&rft.subject=+&rft.description=abstrak+indonesia%0D%0ASistem+tata+udara+merupakan+sistem+pengkondisian+udara+yang+berfungsi+untuk+mengatur+tingkat+kenyamanan+baik+suhu+maupun+kelembaban+udaranya.+Sistem+tata+udara+pada+Gedung+Rektorat+Universitas+Lampung+(UNILA)+masih+terbilang+kurang+baik%2C+dikarenakan+pemakaian+AC+(Air+Conditioner)+yang+kurang+bijak+dan+tidak+sesuai+dengan+standar+operasi+pemakaian+serta+penempatan+AC+(Air+Conditioner)+yang+salah%2C+sehingga+menyebabkan+konsumsi+energi+listrik+di+Gedung+Rektorat+UNILA+mengalami+peningkatan+setiap+bulannya.+Karenanya+perlu+dilakukan+penelitian+di+Gedung+Rektorat+UNILA+melalui+manajemen+sistem+tata+udara%2C+untuk+mengetahui+besarnya+energi+listrik+yang+dikonsumsi+untuk+sistem+tata+udara.%0D%0ANilai+Intensitas+Konsumsi+Energi+(IKE)+diperoleh+sebesar+3.13+kWh%2Fm%C2%B2+per+bulan%2C+hasil+ini+merupakan+hasil+yang+sangat+efisien+menurut+standar+Per+Men+ESDM+no.13+tahun+2012+yaitu+kurang+dari+8.5+kWh%2Fm%C2%B2+per+bulan.+Selain+itu+untuk+tingkat+kenyamanan+didapatkan+hasil+rata-rata+68.18%25+untuk+kelembaban+dan+27.4%C2%BAC+untuk+suhu+ruangan%2C+nilai+ini+belum+mencapai+standar+yang+ditetapkan+oleh+SNI+6390-2011+yaitu+55+%25+hingga+65+%25+untuk+kelembaban+dan+24+oC+hingga+27+oC+untuk+suhu.+Beban+pendinginan+dihitung+menggunakan+metoda+Perbedaan+Temperatur+Ekuivalen+Total+(TETD%2FTA)+dan+didapatkan+hasil+beban+maksimum+terjadi+pada+pukul+16.00+atau+pada+pukul+4+sore+dengan+total+beban+sensibel+dan+laten+sebesar+1087062.53+btu%2Fh.+Pemakaian+energi+AC+pada+Gedung+Rektorat+UNILA+sebesar+761.4+kWh+per+hari+dengan+perbandingan+total+pemakaian+energi+gedung+sebesar+1006.62+kWh+per+hari.+Secara+keseluruhan%2C+AC+(Air+Conditioner)+menyumbang+pemakaian+energi+sebesar+75.63%25+dari+total+pemakaian+energi+pada+Gedung+Rektorat+UNILA.%0D%0AKata+kunci+%3A+Beban+pendinginan%2C+Gedung+Rektorat+UNILA%2C+Intensitas+Konsumsi+Energi%2C+sistem+tata+udara%0D%0A%0D%0Aabstract+inggris%0D%0AHVAC+(Heating%2C+Ventilation%2C+and+Air+Conditioning)+system+is+air+conditioning+system+to+adjust+the+comfort+level+of+both+the+ambient+temperature+and+air+humidity.+HVAC+system+in+the+Rectorate+Building+of+Universitas+Lampung+(UNILA)+still+not+good%2C+because+the+use+of+AC+(Air+Conditioner)+are+less+wise+and+not+in+accordance+with+standard+usage+and+placement+operations+AC+(Air+Conditioner)+is+not+standard%2C+that+causing+energy+consumption+in+the+Rectorate+Building+of+UNILA+increase+every+month.+Because+that%2C+research+was+need+at+Rectorate+Building+of+UNILA+through+management+of+the+HVAC+system%2C+to+calculate+electrical+energy+consumption+that+consumed+for+air+conditioning+system.%0D%0AEnergy+Consumption+Intensity+(IKE)+values+obtained+of+3.13+kWh%2Fm%C2%B2+per+month%2C+this+result+is+a+highly+efficient+results+according+to+Permen+ESDM+no.13+in+2012+is+less+than+8.5+kWh%2Fm%C2%B2+per+month.+In+addition+to+the+comfort+level+of+the+results+obtained+average+of+68.18%25+for+humidity+and+27.4%C2%BAC+for+room+temperature%2C+this+value+has+not+reached+the+standards+set+by+SNI+6390-2011+is+55%25+to+65+%25+for+humidity+and+24+oC+to+27+oC+for+tempereture.+Cooling+load+is+calculated+using+the+method+Total+Equivalent+Temperature+Difference+(TETD%2FTA)+and+the+results+obtained+maximum+load+occurs+at+16.00+or+at+4+pm+with+a+total+load+of+sensible+and+latent+is+1087062.53+btu%2Fh.+AC+energy+consumption+in+the+Rectorate+Building+of+UNILA+is+761.4+kWh+per+day+with+a+ratio+of+total+building+energy+consumption+by+1006.62+kWh+per+day.+Overall%2C+AC+(Air+Conditioner)+Energy+consumption+accounted+for+75.63%25+of+total+energy+consumption+in+the+Rectorate+Building+of+UNILA.%0D%0AKeywords+%3A+Cooling+load%2C+Rectorate+Building+of+UNILA%2C+Energy+Consumption+Intensity%2C+HVAC+systems&rft.publisher=Fakultas+Teknik&rft.date=2014-07-17&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F1%2FABSTRACT.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F2%2FABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F3%2FCOVER%2520DALAM.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F4%2FHALAMAN%2520PERSETUJUAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F5%2FHALAMAN%2520PENGESAHAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F6%2FPERNYATAAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F7%2FRIWAYAT%2520HIDUP.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F8%2FMOTO.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F9%2FPERSEMBAHAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F10%2FSANWACANA.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F11%2FDAFTAR%2520ISI.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F12%2FDAFTAR%2520TABEL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F13%2FDAFTAR%2520GAMBAR.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F14%2FBAB%2520I.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F15%2FBAB%2520II.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F16%2FBAB%2520III.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F17%2FBAB%2520IV.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F18%2FBAB%2520V.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F19%2FDAFTAR%2520PUSTAKA.pdf&rft.identifier=++Andrie+Dwi+Setyawan%2C+0815031038++(2014)+MANAJEMEN+SISTEM+TATA+UDARA+PADA+GEDUNG+REKTORAT+UNIVERSITAS+LAMPUNG.++Fakultas+Teknik%2C+Universitas+Lampung.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F5356%2F