?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=PENENTUAN+LOKASI+DAN+KAPASITAS+DARI+KAPASITOR+SERTA%0D%0APEMBANGKIT+TERSEBAR+UNTUK+MEMINIMALKAN+RUGI-RUGI%0D%0ADAYA+PADA+PENYULANG+KOPI+MENGGUNAKAN+METODE%0D%0APARTICLE+SWARM+OPTIMIZATION+(PSO)%0D%0A&rft.creator=DHARMA+ADI+PUTRA%2C+1215031020&rft.subject=600+Teknologi+(ilmu+terapan)&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Rugi-rugi+daya+adalah+permasalahan+yang+sering+ditemui+pada+sistem+distribusi.%0D%0APenambahan+kapasitor+dan+pembangkit+tersebar+atau+distributed+generation+(DG)%0D%0Amerupakan+salah+satu+solusi+dalam+memperbaiki+permasalahan+tersebut.+Akan%0D%0Atetapi%2C+penentuan+lokasi+dan+kapasitas+dari+kapasitor+serta+pembangkit+tersebar%0D%0Aperlu+dilakukan+analisis+study+agar+hasil+yang+diinginkan+optimal.+Penelitian+ini%0D%0Abertujuan+untuk+menentukan+lokasi+dan+kapasitas+dari+kapasitor+serta+pembangkit%0D%0Atersebar+untuk+meminimalkan+rugi-rugi+daya+pada+sistem+distribusi+dengan%0D%0Amenggunakan+metode+particle+swarm+optimization+(PSO).+Penulis+menggunakan%0D%0Akasus+pada+penyulang+Kopi+di+gardu+induk+Bukit+Kemuning+PT+PLN+(Persero)%0D%0ATbk.+Penelitian+ini+menggunakan+pembangkit+tersebar+dengan+faktor+daya+1+dan%0D%0A0%2C85.+Dari+hasil+simulasi+menunjukkan+bahwa+pada+pembangkit+tersebar+dengan%0D%0Afaktor+daya+1+kapasitas+optimum+kapasitor+sebesar+0%2C4+MVAr+yang+ditempatkan%0D%0Apada+bus+89+dan+kapasitas+optimum+pembangkit+tersebar+sebesar+0%2C8819+MW%0D%0Ayang+ditempatkan+pada+bus+76.+Sedangkan+pada+pembangkit+tersebar+dengan%0D%0Afaktor+daya+0%2C85+kapasitas+optimum+kapasitor+sebesar+0%2C25+MVAr+yang%0D%0Aditempatkan+pada+bus+22+dan+kapasitas+optimum+pembangkit+tersebar+sebesar%0D%0A0%2C6840+MW+yang+ditempatkan+pada+bus+89.+Setelah+pemasangan+kapasitor+dan%0D%0Apembangkit+tersebar+sesuai+dengan+kapasitas+serta+lokasi+yang+ditentukan%2C+dapat%0D%0Ameminimalkan+rugi-rugi+daya+dibandingkan+sebelum+pemasangan.+Penurunan%0D%0Arugi-rugi+daya+memiliki+nilai+yang+sama+baik+dengan+pembangkit+tersebar+dengan%0D%0Afaktor+daya+1+maupun+pembangkit+tersebar+dengan+faktor+daya+0%2C85.+Setelah%0D%0Apemasangan+kapasitor+serta+pembangkit+tersebar%2C+rugi-rugi+daya+aktif+menjadi%0D%0A0%2C006+MW+dari+sebelumnya+sebesar+0%2C039+MW+dan+rugi-rugi+daya+reaktif+menjadi%0D%0A0%2C01+MVAr+dari+sebelumnya+sebesar+0%2C05+MVAr.%0D%0AKata+kunci+%3A+DG%2C+kapasitor%2C+lokasi+dan+kapasitas%2C+PSO%2C+rugi-rugi+daya.%0D%0A%0D%0A%0D%0APower+losses+are+a+problem+that+is+often+encountered+in+distribution+systems.+The%0D%0Aaddition+of+capacitors+and+distributed+generation+(DG)+is+one+of+the+solutions+in%0D%0Afixing+the+problem.+However%2C+determining+the+location+and+capacity+of+capacitors%0D%0Aand+distributed+generation+needs+to+be+analyzed+by+the+study+so+that+the+desired%0D%0Aresults+are+optimal.+This+study+aims+to+determine+the+location+and+capacity+of%0D%0Acapacitors+and+scattered+generators+to+minimize+power+losses+in+distribution%0D%0Asystems+using+the+particle+swarm+optimization+(PSO)+method.+The+author+uses+the%0D%0Acase+of+Kopi+feeders+in+the+Bukit+Kemuning+substation+PT+PLN+(Persero)+Tbk.%0D%0AThis+study+uses+a+distributed+generation+with+a+power+factor+of+1+and+0%2C85.+From%0D%0Athe+simulation+results+show+that+the+distributed+generation+with+a+power+factor+1%2C%0D%0Athe+optimum+capacity+of+capacitors+is+0%2C4+MVAr+which+is+placed+on+bus+89+and%0D%0Athe+optimum+capacity+of+distributed+generation+is+0%2C8819+MW+which+is+placed+on%0D%0Abus+76.+Whereas+distributed+generation+with+power+factor+0%2C85+optimum+capacitor%0D%0Acapacity+of+0%2C25+MVAr+placed+on+bus+22+and+optimum+capacity+of+distributed%0D%0Ageneration+0%2C6840+MW+placed+on+bus+89.+After+installation+of+capacitors+and%0D%0Adistributed+generation+according+to+the+capacity+and+location+specified%2C+can%0D%0Aminimize+power+losses+compared+before+installation.+The+reduction+in+power%0D%0Alosses+has+the+same+value+both+distributed+generation+with+power+factor+1+and%0D%0Adistributed+generation+with+power+factor+0%2C85.+After+the+installation+of+capacitors%0D%0Aand+distributed+generation%2C+the+active+power+losses+are+decreased+to+0%2C006+MW%0D%0Afrom+the+previous+0%2C039+MW+and+the+reactive+power+losses+decreased+to+0%2C01%0D%0AMVAr+from+the+previous+0%2C05+MVAr.%0D%0AKeywords+%3A+DG%2C+capacitor%2C+location+and+capacity%2C+PSO%2C+power+losses.&rft.publisher=Fakultas+Teknik&rft.date=2019-12-09&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F56576%2F1%2FABSTRAK-ABSTRACT.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F56576%2F2%2FSKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F56576%2F3%2FSKRIPSI%2520TANPA%2520BAB%2520PEMBAHASAN.pdf&rft.identifier=++DHARMA+ADI+PUTRA%2C+1215031020++(2019)+PENENTUAN+LOKASI+DAN+KAPASITAS+DARI+KAPASITOR+SERTA+PEMBANGKIT+TERSEBAR+UNTUK+MEMINIMALKAN+RUGI-RUGI+DAYA+PADA+PENYULANG+KOPI+MENGGUNAKAN+METODE+PARTICLE+SWARM+OPTIMIZATION+(PSO).++Fakultas+Teknik%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F56576%2F