<> "The repository administrator has not yet configured an RDF license."^^ . <> . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n"^^ . "Hypoxemia is a condition in which the body lacks oxygen or below 90% which can\r\ncause a person experiencing shortness of breath, or in organs such as the heart can\r\nlead to infarction (death of tissue). So we need a tool that can calculate the amount\r\nof oxygen (O2) in the human body. Oximeter is a device used to measure dan\r\nmonitore oxygen levels in human blood by measurement of hemoglobin levels to\r\nhelp assess the physical condition of humans without taking the blood sample or\r\ninvasive method. Oxygen saturation level is a parameter that can be used to\r\ndetermine the presence of respiratory diffusion and prevent early the hypoxemia\r\nwhich it can cause a person feel breathless and refer to an infarction or death in a\r\nbody tissue. The oximeter uses the Oximeter DS-100A sensor with different\r\nwavelengths of red light LED (660 nm) and infrared LED (940 nm) and the light is\r\nreceived by the photodiode after being transferred through the blood at the\r\nfingertips. NodeMCU ESP 8266 microcontroller is used to process data from the\r\nphotodiode, then the data that has been processed on the microcontroller is\r\ndisplayed on the LCD and Buzzer as an indicator that indicate the patient’s\r\ncondition. The error results of measuring oxygen levels reached 1.02% while it’s\r\ncompared to standard measuring devices.\r\nKeywords : Oximeter, oxygen saturation, and hypoxemia\r\n\r\n\r\nHipoksemia merupakan suatu kondisi dimana tubuh kekurangan oksigen atau\r\nberada dibawah 90% yang dapat menyebabkan seseorak mengalami sesak nafas,\r\natau pada organ seperti jantung dapat berujung pada infark (matinya jaringan).\r\nUntuk itu dibutuhkan alat yang dapat mengukur dan memonitoring jumlah satuasi\r\noksigen (O2) dalam tubuh manusia. Oksimeter merupakan alat yang digunakan\r\nuntuk mengukur saturasi oksigen dalam darah manusia melalui pengukuran kadar\r\nhemoglobin untuk membantu menentukan kondisi fisik manusia tanpa melalui\r\nanalisa tes darah atau invasive. Kadar saturasi oksigen merupakan parameter yang\r\ndapat digunakan untuk mengetahui adanya difusi pernafasan dan mencegah lebih\r\ndini terjadinya Hipoksemia yang dapat menyebabkan seseorang mengalami sesak\r\nnafas dan merujuk pada infark. Oximeter menggunakan sensor Oximeter DS-100A\r\ndengan panjang gelombang dari cahaya LED merah (660 nm) dan cahaya LED\r\ninframerah (940 nm) dan fotodioda sebagai detektor yang dideteksi perubahan\r\npenyerapan cahaya oleh jari. Mikrokontroler NodeMCU ESP 8266 digunakan\r\nuntuk memproses data dari fotodioda, kemudian data dari mikrokontroler\r\nditampilkan pada LCD dan Buzzer sebagai inidikator yang mengindikasikan\r\nkeadaan seseorang. Hasil pengukuran saturasi oksigen mempunyai tingkat error\r\n1.02 % dibanding dengan alat ukur standar.\r\nKata kunci : Oksimeter, saturasi oksigen, hipoksemia."^^ . "2019-09-17" . . . . . "Fakultas Teknik"^^ . . . . . . . "1515031001"^^ . "Mutia Aziza"^^ . "1515031001 Mutia Aziza"^^ . . . . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (File PDF)"^^ . . . "ABSTRAK-ABSTRACT.pdf"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (File PDF)"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (File PDF)"^^ . . . "SKRIPSI TANPA PEMBAHASAN MUTIA AZIZA.pdf"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "lightbox.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "preview.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "medium.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "small.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "indexcodes.txt"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "indexcodes.txt"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "lightbox.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "preview.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "medium.jpg"^^ . . . "RANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR\r\nOXIMETER DS-100A BERBASIS MIKROKONTROLER\r\nNODEMCU ESP 8266\r\n (Other)"^^ . . . . . . "small.jpg"^^ . . "HTML Summary of #56637 \n\nRANCANG BANGUN ALAT UKUR SATURASI OKSIGEN NONINVASIVE DALAM DARAH MANUSIA MENGGUNAKAN SENSOR \nOXIMETER DS-100A BERBASIS MIKROKONTROLER \nNODEMCU ESP 8266 \n\n\n" . "text/html" . . . "600 Teknologi (ilmu terapan)" . . . "620 Ilmu teknik dan ilmu yang berkaitan" . .