?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=DETEKSI+MODA+INTERAREA+OSCILLATION+DAN+ESTIMASI%0D%0ADAMPING+RATIO+DENGAN+METODE+COMPLEX+MORLET+CWT%0D%0ASTUDI+KASUS+SISTEM+INTERKONEKSI+JAWA+BALI&rft.creator=RIDWAN+KURNIAWAN%2C+1515031004&rft.subject=600+Teknologi+(ilmu+terapan)&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Osilasi+sistem+tenaga+merupakan+permasalahan+kestabilan+sistem+tenaga+dinamis.%0D%0AKestabilan+sistem+tenaga+dinamis+yang+tidak+diantisipasi+secara+dini+dapat%0D%0Amenyebabkan+terjadinya+blackout.+Metode+Complex+Morlet+Wavelet+Transform%0D%0Adigunakan+untuk+mendeteksi+kestabilan+sistem+dinamis+karena+memiliki%0D%0Akemampuan+untuk+melokalisir+informasi+waktu+dan+frekuensi+secara+bersamaan.%0D%0APengujian+metode+Complex+Morlet+Wavelet+Transform+dilakukan+terhadap+sinyal%0D%0Asistesis+dengan+parameter+yang+sudah+diketahui.+Hasil+estimasi+metode+Complex%0D%0AMorlet+Wavelet+Transform+juga+dibandingkan+terhadap+hasil+perhitungan+dengan%0D%0Ametode+nilai+eigen+pada+model+Two+Area+Four+Machine+System+untuk+memvalidasi%0D%0Ametode+yang+digunakan.%0D%0AMetode+Complex+Morlet+Wavelet+Transform+digunakan+untuk+mendeteksi+moda%0D%0Ainterarea+oscillation+dan+estimasi+damping+ratio+pada+sistem+interkoneksi+JawaBali.+Dari+hasil+estimasi%2C+sistem+interkoneksi+Jawa-Bali+memiliki+moda+interarea%0D%0Aoscillation+sekitar+0.5+Hz+dan+0.83+Hz+serta+memiliki+damping+ratio+terendah+hingga%0D%0Adi+bawah+3%25.%0D%0AKata+kunci+%3A+interarea+oscillation%2C+estimasi+damping+ratio%2C+complex+morlet+wavelet%2C%0D%0Asistem+interkoneksi+Jawa-Bali%2C+kestabilan+dinamis.%0D%0A%0D%0A%0D%0APower+system+oscillation+is+a+problem+of+power+system+dynamic+stability.+Power%0D%0Asystems+dynamic+stability+that+is+not+anticipated+early+can+cause+a+blackout.+The%0D%0AComplex+Morlet+Wavelet+Transform+method+was+used+to+detect+system+dynamic%0D%0Astability+owing+to+its+ability+to+localize+time+and+frequency+information%0D%0Asimultaneously.+The+verification+of+the+Complex+Morlet+Wavelet+Transform%0D%0Aapproach+was+performed+on+the+synthesized+signal+with+known+parameters.+The%0D%0Aestimation+results+of+the+technique+were+also+compared+to+the+results+of+calculations%0D%0Awith+the+eigenvalue+method+in+the+Two+Area+Four+Machine+System+model+to%0D%0Avalidate+the+result.%0D%0AThe+Complex+Morlet+Wavelet+Transform+approach+was+used+to+detect+interarea%0D%0Aoscillation+mode+and+damping+ratio+estimation+in+the+Java-Bali+interconnection%0D%0Asystem.+From+the+estimation+results%2C+the+Java-Bali+interconnection+system+has+an%0D%0Ainterarea+oscillation+mode+of+around+0.5+Hz+and+0.83+Hz+and+has+the+lowest+damping%0D%0Aof+about+close+to+3%25.%0D%0AKeywords+%3A+interarea+oscillation%2C+damping+ratio+estimation%2C+complex+morlet%0D%0Awavelet%2C+Jawa-Bali+interconnection+system%2C+dynamic+stability.&rft.publisher=Fakultas+Teknik&rft.date=2019-11-13&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F56679%2F1%2FABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F56679%2F2%2FSkripsi%2520Full.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F56679%2F3%2FSkripsi%2520Tanpa%2520Bab%2520Pembahasan.pdf&rft.identifier=++RIDWAN+KURNIAWAN%2C+1515031004++(2019)+DETEKSI+MODA+INTERAREA+OSCILLATION+DAN+ESTIMASI+DAMPING+RATIO+DENGAN+METODE+COMPLEX+MORLET+CWT+STUDI+KASUS+SISTEM+INTERKONEKSI+JAWA+BALI.++Fakultas+Teknik%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F56679%2F