title: EVALUASI KINERJA STRUKTUR GEDUNG BERTINGKAT DENGAN ANALISIS TIME HISTORY (Studi Kasus : Rumah Sakit Umum Muhammadiyah Metro) creator: MUHAMAD RIFAI, 1715011001 subject: 620 Ilmu teknik dan ilmu yang berkaitan description: ABSTRAK EVALUASI KINERJA STRUKTUR GEDUNG BERTINGKAT DENGAN ANALISIS TIME HISTORY (STUDI KASUS : RUMAH SAKIT UMUM MUHAMMADIYAH METRO) Oleh MUHAMAD RIFAI Penelitian ini mengevaluasi sturktur gedung bertingkat dengan jumlah lantai 7 lantai dan 1 basement menggunakan metode analisis riwayat waktu (Time History) dengan 5 rekaman gempa (akselerogram) yang digunakan, antara lain : El Centro (US, 1940), Chichi (Taiwan, 1999), Gempa Mentawai (Sumatera, 2007), Friuli (Italia, 1976), dan Superstition Hills (USA, 1987). Analisis struktur dihitung menggunakan softwere ETABS dalam model 3 dimensi (3D) dengan tujuan untuk mengevaluasi kinerja struktur bangunan bertingkat menurut SNI 1726-2019. Setelah dilakukan penelitian didapatkan hasil penelitian yaitu nilai periode fundamental alami hasil ETABS untuk arah X sebesar 2,6730 dan arah Y sebesar 2,3130 detik, nilai periode ini melebihi periode maksimal yaitu sebesar Tx = 1,4346 dan Ty = 0,8976 detik. Nilai geser dasar sudah memenuhi persyaratan dimana nilai Vt lebih besar 100% dari V, perbandingan nilai gaya dan momen antara analisis statis ekuivalen dan analisis dinamik time history tidak lebih dari 10%. Hasil kontrol drift apabila dianalisis menggunakan 5 rekaman gempa simpangan yang terjadi pada struktur gedung memenuhi syarat simpangan antar tingkat izin untuk arah X dan arah Y nya. Kata kunci : Gempa bumi, analisis time history, kinerja struktur ABSTRACT PERFORMANCE EVALUATION OF STORE BUILDING STRUCTURE WITH TIME HISTORY ANALYSIS (Case Study: Muhammadiyah Metro General Hospital) By MUHAMAD RIFAI This study evaluates the structure of a multi-storey building with 7 floors and 1 basement using the Time History analysis method with 5 earthquake records (accelerograms) used, including: El Centro (US, 1940), Chichi (Taiwan, 1999) , Mentawai Earthquake (Sumatra, 2007), Friuli (Italy, 1976), and Superstition Hills (USA, 1987). Structural analysis is calculated using ETABS software in a 3-dimensional model with the aim of evaluating the performance of high-rise building structures according to SNI 1726-2019. After doing the research, the research results obtained that the value of the natural fundamental period of ETABS results for the X direction is 2.6730 and the Y direction is 2.3130 seconds, the value of this period exceeds the maximum period of Tx = 1.4346 and Ty = 0.8976 seconds. The basic shear value has met the requirements where the value of Vt is more than 100% of V, the comparison of the value of the force and moment between the equivalent static analysis and the dynamic analysis of time history is not more than 10%. The results of drift control when analyzed using 5 records of earthquake deviations that occur in the building structure meet the requirements for deviations between permit levels for the X direction and the Y direction. Keywords: Earthquake, time history analysis, structural performance publisher: FAKULTAS TEKNIK date: 2022-03-24 type: Skripsi type: NonPeerReviewed format: text identifier: http://digilib.unila.ac.id/59337/1/ABSTRAK-MUHAMAD%20RIFAI-1715011001.pdf format: text identifier: http://digilib.unila.ac.id/59337/2/FILE%20SKRIPSI%20FULL%20-%20MUHAMAD%20RIFAI-1715011001.pdf format: text identifier: http://digilib.unila.ac.id/59337/3/FILE%20SKRIPSI%20TANPA%20PEMBAHASAN%20-%20MUHAMAD%20RIFAI-1715011001.pdf identifier: MUHAMAD RIFAI, 1715011001 (2022) EVALUASI KINERJA STRUKTUR GEDUNG BERTINGKAT DENGAN ANALISIS TIME HISTORY (Studi Kasus : Rumah Sakit Umum Muhammadiyah Metro). FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG. relation: http://digilib.unila.ac.id/59337/