?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=EVALUASI+KINERJA+STRUKTUR+GEDUNG+BERTINGKAT%0D%0AMENGGUNAKAN+NON+LINEAR+STATIC+PUSHOVER+ANALYSIS%0D%0ADENGAN+CAPACITY+SPECTRUM+METHOD+(CSM)%0D%0A(Studi+Kasus%3A+Gedung+B+Rumah+Sakit+Umum+Muhammadyah+Metro)&rft.creator=RISA+KURNIAWATI%2C+1715011008&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Indonesia+merupakan+wilayah+rawan+gempa+bumi.+Salah+satu+upaya+untuk%0D%0Amengantisipasi+dampak+bencana+gempa+bumi+adalah+dengan+memenuhi+kebutuhan%0D%0Aakan+bangunan+tahan+gempa.+Untuk+menjaga+keselamatan+penghuninya%2C%0D%0Abangunan+harus+memberikan+kinerja+yang+optimal.+Maka+dari+itu%2C+diperlukan%0D%0Asuatu+analisis+gaya+gempa+dalam+hal+ini+analisis+pushover.+Analisis+pushover%0D%0Aadalah+suatu+analisis+dimana+pengaruh+gempa+rencana+pada+struktur+dianggap%0D%0Asebagai+beban+statik+yang+menangkap+pada+pusat+massa+masing-masing+lantai.%0D%0APenelitian+ini+mengambil+studi+kasus+pada+Gedung+B+Rumah+Sakit+Umum%0D%0AMuhammadyah+Metro.+Penelitian+ini+bertujuan+untuk+mengetahui+performance%0D%0Apoint+dan+kriteria+level+kinerja+gedung+menggunakan+analisis+pushover+dengan%0D%0Acapacity+spectrum+method+(CSM).+Adapun+peraturan+standar+yang+digunakan%0D%0Apada+penelitian+ini+antara+lain+SNI+1727-2020%2C+SNI+1726-2019%2C+FEMA-440%0D%0A(2005)%2C+serta+ATC-40+(1996).+Berdasarkan+hasil+penelitian+disimpulkan+bahwa%0D%0AGedung+menunjukkan+kinerja+damage+control+jika+dilihat+dari+data+perencanaan%0D%0Adengan+konsep+struktur+ideal.+Namun%2C+struktur+gedung+ini+pada+kondisi+eksisting%0D%0Atidak+memenuhi+konsep+keruntuhan+ideal.+Dengan+demikian.+apabila+terjadi%0D%0Agempa%2C+perilaku+daktail+parsial+pada+gedung+mengakibatkan+kerusakan+struktur%0D%0Atetapi+tidak+runtuh.+Gempa+tersebut+memiliki+masa+layan+selama+umur+struktur%0D%0Abangunan+50+tahun+adalah+10%25.%0D%0AKata+kunci%3A+Analisis+pushover%2C+Gempa%2C+Level+Kinerja%0D%0AIndonesia+is+an+earthquake+prone+area.+One+of+the+efforts+to+anticipate+the+impact%0D%0Aof+an+earthquake+is+to+meet+the+need+for+earthquake-resistant+buildings.+To%0D%0Amaintain+the+safety+of+its+occupants%2C+buildings+must+provide+optimal+performance.%0D%0ATherefore%2C+an+earthquake+force+analysis+is+needed+in+this+case+a+pushover+analysis.%0D%0APushover+analysis+is+an+analysis+where+the+influence+of+the+design+earthquake+on%0D%0Athe+structure+is+considered+as+a+static+load+that+captures+the+center+of+mass+of+each%0D%0Afloor.+This+research+takes+a+case+study+in+The+B+Building+of+Muhammadyah%0D%0AMetro+General+Hospital.+The+purpose+of+this+study+to+determine+the+performance%0D%0Apoint+and+building+performance+level+using+pushover+analysis+with+the+capacity%0D%0Aspectrum+method+(CSM).+The+standard+provisions+used+in+this+study+refer+to+SNI%0D%0A1727-2020%2C+SNI+1726-2019%2C+FEMA-440+(2005)%2C+and+ATC-40+(1996).+Based+on%0D%0Athe+results%2C+it+can+be+concluded+that+this+Building+shows+performance+with+a+level%0D%0Aof+damage+control+when+viewed+from+the+planning+data+with+the+concept+of+an%0D%0Aideal+structure.+However%2C+the+structure+of+this+building+in+the+existing+condition%0D%0Adoesn%E2%80%99t+meet+the+ideal+collapse+concept.+Therefore.+in+the+event+of+an+earthquake%2C%0D%0Athe+partial+ductile+behavior+of+the+building+results+in+structural+damage+but+doesn%E2%80%99t%0D%0Acollapse.+The+earthquake+has+a+probability+of+being+exceeded+during+the+life+of+the%0D%0Astructure+of+50+years+is+10%25.%0D%0AKeywords%3A+Pushover+Analysis%2C+Earthquake%2C+Performance+Level&rft.publisher=FAKULTAS+TEKNIK&rft.date=2021&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F61846%2F1%2F1.%2520ABSTRAK%2520RISA%2520-%2520Risa%2520Kurniawati.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F61846%2F2%2F2.%2520SKRIPSI%2520LENGKAP%2520RISA%2520TANPA%2520LAMPIRAN-RISA.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F61846%2F3%2F3.%2520SKRIPSI%2520RISA%2520TANPA%2520PEMBAHASAN-RISA.pdf&rft.identifier=++RISA+KURNIAWATI%2C+1715011008++(2021)+EVALUASI+KINERJA+STRUKTUR+GEDUNG+BERTINGKAT+MENGGUNAKAN+NON+LINEAR+STATIC+PUSHOVER+ANALYSIS+DENGAN+CAPACITY+SPECTRUM+METHOD+(CSM)+(Studi+Kasus%3A+Gedung+B+Rumah+Sakit+Umum+Muhammadyah+Metro).++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F61846%2F