?url_ver=Z39.88-2004&rft_id=1815031060&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=STUDI+PENEMPATAN+DAN+PENENTUAN+UKURAN+KAPASITOR+SHUNT+PADA+PENYULANG+RAMBUTAN%2C+PLN+ULP+METRO%0D%0A%0D%0ASTUDY+OF+PLACEMENT+AND+DETERMINATION+OF+SIZING+OF+SHUNT+CAPACITORS+IN+RAMBUTAN+FEEDERS%2C+PLN+ULP+METRO&rft.creator=MUHAMMAD+IQBAL%2C+HASAN&rft.subject=600+Teknologi+(ilmu+terapan)&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Energi+listrik+merupakan+suatu+kebutuhan+yang+berperan+sangat+penting+diseluruh+dunia.+Dari+kebutuhan+energi+listrik+inilah+dibutuhkan+pengaturan+sistem+distribusi+listrik+yang+mampu+menyalurkan+listrik+sesuai+kebutuhan+masyarakat+saat+ini%2C+akan+tetapi+gangguan+pada+sistem+tenaga+listrik+belum+dapat+dihindari+dikarenakan+adanya+beberapa+faktor+yang+dapat+mempengaruhi+sistem+distribusi%2C+diantaranya+yaitu+jarak+pada+saluran+distribusi+melingkupi+daerah+yang+luas+serta+banyaknya+beban+industri+maupun+residensial.+Pada+penyulang+Rambutan+jaringan+distribusi+PLN+ULP+Metro%2C+Lampung%2C+terdapat+fluktuasi+tegangan+yang+diakibatkan+oleh+banyaknya+beban+industri+maupun+residensial+yang+tersebar+ke+daerah-daerah+setempat+dan+dengan+jarak+penyulang+yang+jauh+dari+Gardu+Induk%2C+beban+industrial+di+daerah+tersebut+pun+terbilang+cukup+banyak+sehingga+menyebabkan+tegangan+jatuh+pada+penyulang+Rambutan+tersebut.+Meskipun+terdapat+IPP+PLTBg+yang+tersambung+sebagai+Distributed+Generation+yang+dapat+memperbaiki+profil+tegangan%2C+gangguan+pada+penyulang+tersebut+belum+sepenuhnya+teratasi+dikarenakan+beberapa+kondisi+seperti+saat+PLTBg+sedang+tidak+dapat+beroperasi.+Penelitian+ini+menggunakan+kapasitor+shunt+yang+berfungsi+menyerap+daya+reaktif+atau+memperbaiki+faktor+daya+dan+mengurangi+tegangan+jatuh.+Pada+penelitian+ini+menggunakan+software+DigSilent+PowerFactory+15.1+untuk+mensimulasikan+pemasangan+kapasitor+shunt.+Berdasarkan+hasil+simulasi+penempatan+kapasitor+shunt+sebesar+1%2C2+Mvar+pada+penyulang+rambutan+menggunakan+DigSilent+dengan+melakukan+8+skenario+pada+Bus+SM069+maka+diperoleh+tegangan+jatuh+sebesar+4%2C78%25+dari+tegangan+jatuh+semula+sebelum+dipasang+kapasitor+shunt+yaitu+sebesar+8%2C47%25(mengalami+penurunan+tegangan+jatuh+sebesar+3%2C69%25).+Dalam+hal+ini+kapasitor+shunt+berfungsi+untuk+memperbaiki+profil+tegangan+dengan+cara+menyuplai+daya+reaktif+pada+saluran.+Dengan+demikian+pemasangan+kapasitor+shunt+pada+Bus+SM069+mampu+memperbaiki+profil+tegangan.+%0D%0A%0D%0AElectrical+energy+is+a+necessity+that+plays+a+very+important+role+throughout+the+world.+From+this+need+for+electrical+energy%2C+it+is+necessary+to+regulate+an+electricity+distribution+system+that+is+capable+of+flowing+electricity+according+to+the+current+needs+of+the+community%2C+however%2C+disturbances+in+the+electric+power+system+cannot+be+avoided+due+to+several+factors+that+can+affect+the+distribution+system%2C+including+the+distance+to+the+distribution+channels+covering+a+large+area.+as+well+as+many+industrial+and+residential+burdens.+In+the+Rambutan+feeder+of+the+PLN+ULP+Metro+distribution+network%2C+Lampung%2C+there+are+voltage+fluctuations+caused+by+the+large+number+of+industrial+and+residential+loads+that+are+spread+to+local+areas+and+with+the+feeder+distance+being+far+from+the+substation%2C+the+industrial+load+in+the+area+is+quite+a+lot%2C+causing+voltage+drop+on+the+rambutan+feeder.+Even+though+there+is+a+PLTBg+IPP+that+is+connected+as+a+Distributed+Generation+which+can+improve+the+voltage+profile%2C+the+disturbance+to+the+feeder+has+not+been+fully+resolved+due+to+several+conditions+such+as+when+the+PLTBg+was+unable+to+operate.+This+study+uses+the+purchase+of+a+shunt+that+functions+to+absorb+reactive+power+or+improve+power+factor+and+reduce+voltage+drops.+In+this+study%2C+DigSilent+PowerFactory+15.1+software+was+used+to+simulate+shunt+installation.+Based+on+the+simulation+results+of+placing+a+1.2+Mvar+shunt+auction+on+rambutan+feeders+using+DigSilent+by+carrying+out+8+scenarios+on+the+SM069+Bus%2C+a+voltage+drop+of+4.78%25+was+obtained+from+the+initial+voltage+drop+before+the+closing+of+the+shunt+was+installed%2C+namely+8.47%25+(experiencing+a+voltage+drop+fell+by+3.69%25).+In+this+case%2C+the+shunt+loss+serves+to+improve+the+profile+voltage+by+restoring+the+reactive+power+on+the+line.+Thus+the+installation+of+a+shunt+on+the+SM069+Bus+can+improve+the+voltage+profile.+&rft.publisher=FAKULTAS+TEKNIK&rft.date=2023-03-20&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F71209%2F1%2F1.%2520ABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F71209%2F2%2F2.%2520SKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F71209%2F3%2F3.%2520SKRIPSI%2520TANPA%2520BAB%2520PEMBAHASAN.pdf&rft.identifier=++MUHAMMAD+IQBAL%2C+HASAN++(2023)+STUDI+PENEMPATAN+DAN+PENENTUAN+UKURAN+KAPASITOR+SHUNT+PADA+PENYULANG+RAMBUTAN%2C+PLN+ULP+METRO+STUDY+OF+PLACEMENT+AND+DETERMINATION+OF+SIZING+OF+SHUNT+CAPACITORS+IN+RAMBUTAN+FEEDERS%2C+PLN+ULP+METRO.++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F71209%2F