?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=PENENTUAN+LETAK+PENGUKURAN+REFLECTED+TEMPERATURE%0D%0ADENGAN+MENGGUNAKAN+TERMOKOPEL+PADA+PENGUJIAN+%0D%0ATERMOGRAFI+AKTIF+TERHADAP+BETON+BERTULANG&rft.creator=MUHAMMAD%2C++FAUZAN+IKROMI&rft.subject=690+Pembangunan+gedung&rft.description=ABSTRACT%0D%0A%0D%0AActive+thermography+testing+is+one+of+the+non-destructive+tests+that+uses+an+%0D%0Ainfrared+camera+as+a+recorder+and+produces+a+thermogram.+Thermogram+is+an+%0D%0Ainterpretation+of+the+heat+energy+received+by+the+infrared+camera+thermal+sensor+%0D%0Awhich+still+contains+noise.+Reflected+temperature+(Trefl)+is+one+of+the+noise+that+%0D%0Aarises+from+active+thermography+testing+and+will+be+used+as+a+correction+value.+%0D%0AThis+research+presents+a+method+to+finding+the+position+of+thermocouple+%0D%0Ainstallation+around+the+heat+source%2C+so+that+the+temperature+values+at+that+position+%0D%0Aare+used+as+the+Trefl+value+to+correct+noise+in+the+thermogram.+Cube-shaped+%0D%0Aconcrete+samples+with+a+size+of+10x10x15+cm+were+measured+using+%0D%0Athermocouples+and+infrared+cameras+as+far+as+1+meter%2C+2+meters%2C+and+3+meters.+%0D%0AThe+results+showed+the+difference+in+measurement+results+using+thermocouples+%0D%0Aand+thermography+of+2%2C3499+%E2%84%83%3B+3%2C0246+%E2%84%83%3B+and+3%2C0946+%E2%84%83%2C+then+the+average+%0D%0ATrefl+value+obtained+from+active+thermography+testing+was+51%2C6496+%E2%84%83%3B+57%2C9544+%0D%0A%E2%84%83%3B+and+59%2C7707+%E2%84%83+with+the+thermocouple+located+5+cm+in+front+of+the+halogen+%0D%0Alamp+and+the+average+distance+obtained+by+Trefl+from+the+top+of+the+grid+board+%0D%0Awas+13+cm%3B+18+cm%3B+and+19+cm.+The+average+difference+between+the+data+before+%0D%0Acorrection+and+the+measurement+data+is+2%2C7385+%E2%84%83%3B+3%2C3749+%E2%84%83%3B+and+3%2C4818+%E2%84%83%2C+%0D%0Arespectively%2C+then+after+the+analysis+of+the+calculation+of+the+temperature+%0D%0Adifference+with+the+measurement+results+has+decreased%2C+namely+0%2C4634%E2%84%83%3B+%0D%0A1%2C4829%E2%84%83%3B+and+0%2C4666%E2%84%83+with+the+analysis+of+the+error+(%CE%94Terr)+on+average+%0D%0Aobtained+1%2C4479%25%3B+4%2C3587%25%3B+1%2C3187%25.+Based+on+the+analysis+results%2C+the+%0D%0Aaccuracy+of+the+error+data+is+good+because+the+average+value+of+error+analysis+%0D%0A(%CE%94Terr)+%3C5%25.+This+research+cannot+be+done+deterministically.%0D%0AKeywords+%3A+Reflected+Temperature%2C+Active+thermography%2C+Non-destructive+%0D%0ATesting%0D%0A%0D%0AABSTRACT%0D%0A%0D%0APengujian+termografi+aktif+merupakan+salah+satu+pengujian+non-destruktif+yang+%0D%0Amenggunakan+kamera+inframerah+sebagai+perekam+dan+menghasilkan+%0D%0Atermogram.+Termogram+merupakan+interpretasi+energi+panas+yang+diterima+oleh+%0D%0Asensor+termal+kamera+inframerah+yang+masih+mengandung+noise.+Reflected+%0D%0Atemperature+(Trefl)+merupakan+salah+satu+noise+yang+muncul+dari+pengujian+%0D%0Atermografi+aktif+dan+akan+digunakan+sebagai+nilai+koreksi.+Penelitian+ini+%0D%0Amenyajikan+suatu+metode+untuk+mencari+posisi+pemasangan+termokopel+di+%0D%0Asekitar+sumber+panas%2C+sehingga+nilai+suhu+pada+posisi+tersebut+digunakan+sebagai+%0D%0Anilai+Trefl+untuk+memperbaiki+noise+pada+termogram.+Sampel+beton+berbentuk+%0D%0Akubus+dengan+ukuran+10x10x15+cm+diukur+suhu+permukaannya+menggunakan+%0D%0Atermokopel+dan+kamera+inframerah+sejauh+1+meter%2C+2+meter%2C+dan+3+meter.+Hasil+%0D%0Apenelitian+menunjukkan+selisih+hasil+pengukuran+menggunakan+termokopel+dan+%0D%0Atermografi+sebesar+2%2C3499+%E2%84%83%3B+3%2C0246+%E2%84%83%3B+dan+3%2C0946+%E2%84%83%2C+lalu+rata-rata+nilai+Trefl%0D%0Ayang+didapatkan+dari+pengujian+termografi+aktif+sebesar+51%2C6496%E2%84%83%3B+57%2C9544%E2%84%83%3B+%0D%0Adan+59%2C7707%E2%84%83+dengan+termokopel+terletak+5+cm+di+depan+lampu+halogen+dan+%0D%0Ajarak+rata-rata+yang+didapatkan+Trefl+dari+atas+papan+grid+sebesar+13+cm%3B+18+cm%3B+%0D%0Adan+19+cm.+Selisih+rata-rata+antara+data+sebelum+dikoreksi+dan+data+hasil+%0D%0Apengukuran+berturut-turut+sebesar+2%2C7385%E2%84%83%3B+3%2C3749%E2%84%83%3B+dan+3%2C4818%E2%84%83%2C+lalu+%0D%0Asetelah+dilakukan+analisis+perhitungan+selisih+suhu+dengan+hasil+pengukuran+%0D%0Amengalami+penurunan+yaitu+berturut-turut+sebesar+0%2C4634%E2%84%83%3B+1%2C4829%E2%84%83%3B+dan+%0D%0A0%2C4666%E2%84%83+dengan+analisis+kesalahan+(%CE%94Terr)+rata-rata+didapatkan+1%2C4479%25%3B+%0D%0A4%2C3587%25%3B+1%2C3187%25.+Berdasarkan+hasil+analisis+terebut+menunjukkan+akurasi+data+%0D%0Akesalahan+tergolong+bagus+karena+nilai+rata-rata+analisis+kesalahan+(%CE%94Terr)%3C5%25.%0D%0AUntuk+penelitian+ini+tidak+bisa+dilakukan+secara+deterministik.%0D%0AKeywords+%3A+Reflected+Temperature%2C+Termografi+aktif%2C+Pengujian+Non-destruktif%0D%0A&rft.publisher=TEKNIK&rft.date=2023-11-09&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F76947%2F1%2FABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F76947%2F2%2FSKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F76947%2F3%2FSKRIPSI%2520TANPA%2520BAB%2520IV.pdf&rft.identifier=++MUHAMMAD%2C+FAUZAN+IKROMI++(2023)+PENENTUAN+LETAK+PENGUKURAN+REFLECTED+TEMPERATURE+DENGAN+MENGGUNAKAN+TERMOKOPEL+PADA+PENGUJIAN+TERMOGRAFI+AKTIF+TERHADAP+BETON+BERTULANG.++TEKNIK%2C+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F76947%2F