?url_ver=Z39.88-2004&rft_id=1915031071&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=MONITORING+DAN+KONTROL+KETIDAKSEIMBANGAN+ARUS+FASA%0D%0APADA+SISTEM+DISTRIBUSI+BERBASIS+INTERNET+OF+THINGS+(IoT)&rft.creator=MUCHLAS+%2C+AL+MA%E2%80%99RUF+&rft.subject=600+Teknologi+(ilmu+terapan)&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Ketidakseimbangan+beban+mengakibatkan+penurunan+keandalan+suatu+sistem%0D%0Atenaga%2C+penyebab+ketidakseimbangan+tersebut+adalah+tidakseimbangnya+keadaan%0D%0Abeban+antar+fasa+(fasa+R%2C+fasa+S+dan+fasa+T)+pada+beban+satu+fasa+pada+jaringan%0D%0Ategangan+rendah%2C+batas+maksimal+ketidakseimbangan+beban+menurut+PLN+(SK+ED%0D%0APLN+No.0017.E%2FDIR%2F2014)+sebesar+10%25+dan+sebesar+5%25+-+20%25+berdasarkan+IEEE%0D%0Astd+446+-1995.+Sehingga%2C+diperlukan+peralatan+yang+dapat+memonitoring+dan%0D%0Amengontrol+ketidakseimbangan+beban+sistem+distribusi+berbasis+IoT.+Prototipe%0D%0Ayang+dibangun+terdiri+dari+beberapa+modul+antara+lain+menggunakan%0D%0Amikrokontroler+Arduino+Mega+2560+dan+Nodemcu+ESP8266+berbasis+IoT+(internet%0D%0Aof+things).+Sensor+PZEM-004T+dan+Relay+5V+dihubungkan+dengan+Arduino+Mega%0D%0A2560.+Pengontrolan+ketidakseimbangan+Arus+Fasa+dilakukan+dengan+memindahkan%0D%0Abeban+pada+fasa+R%2C+fasa+S+dan+fasa+T+dengan+pembebanan+pada+Arus+Fasa+terbesar%0D%0Adipindahkan+pada+Arus+Fasa+terkecil+menggunakan+Relay+5V+sehingga+arus%0D%0Aketidakseimbangan+Arus+Fasa+dibawah+standar.+Rancang+bangun+sistem+monitoring%0D%0Adan+kontrol+terhadap+ketidakseimbangan+Arus+Fasa+dapat+berfungsi+dengan+baik%0D%0Adengan+berbasis+IoT+menggunakan+mikrokontroler+Arduino+Mega+2560+dan%0D%0ANodeMCU+ESP8266+telah+berhasil+memonitoring+dan+mengontrol+beban+dengan%0D%0Acara+melakukan+switching+beban+ketika+ketidakseimbangan+Arus+Fasa+terjadi.%0D%0APerbandingan+hasil+pembacaan+daya+listrik+pada+media+monitoring+dengan+hasil+alat%0D%0Aukur+baik+pada+monitoring+arus+dan+tegangan+memiliki+error+arus+sebesar+0%2C077%25%0D%0Adan+error+tegangan+sebesar+0%2C002%25.+Ketika+terjadi+ketidakseimbangan+melebihi%0D%0Astandar+yang+ditentukan%2C+sistem+dapat+melakukan+switching+sehingga%0D%0Aketidakseimbangan+Arus+Fasa+memenuhi+standar+yang+ditentukan.+Hal+ini+baik%0D%0Auntuk+peralatan+dan+beban+yang+digunakan.%0D%0AKata+kunci%3A+Monitoring+dan+Kontrol%2C+Ketidakseimbangan+Fasa%2C+Internet+of+Things.%0D%0A%0D%0ALoad+imbalance+results+in+a+decrease+in+the+reliability+of+a+power+system.+The+cause%0D%0Aof+this+imbalance+is+the+unequal+distribution+of+loads+among+phases+(phase+R%2C+phase%0D%0AS%2C+and+phase+T)+in+a+single-phase+load+on+a+low-voltage+network.+According+to+PLN%0D%0Aregulations+(SK+ED+PLN+No.0017.E%2FDIR%2F2014)%2C+the+maximum+allowable+load%0D%0Aimbalance+is+10%25%2C+and+it+ranges+from+5%25+to+20%25+according+to+IEEE+std+446-1995.%0D%0ATherefore%2C+equipment+is+needed+to+monitor+and+control+load+imbalance+in+IoT-based%0D%0Adistribution+systems.+The+prototype+consists+of+several+modules%2C+including+the%0D%0AArduino+Mega+2560+microcontroller+and+IoT-based+Nodemcu+ESP8266.+The%0D%0APZEM-004T+sensor+and+5V+Relay+are+connected+to+the+Arduino+Mega+2560.%0D%0AControl+of+phase+current+imbalance+is+achieved+by+switching+the+load+among+phases%0D%0AR%2C+S%2C+and+T%2C+with+the+load+on+the+phase+with+the+highest+current+switched+to+the%0D%0Aphase+with+the+lowest+current+using+a+5V+Relay.+This+ensures+that+the+phase+current%0D%0Aimbalance+is+below+the+standard.+The+design+of+the+monitoring+and+control+system%0D%0Afor+phase+current+imbalance+functions+effectively+in+an+IoT-based+environment%0D%0Ausing+the+Arduino+Mega+2560+microcontroller+and+NodeMCU+ESP8266.+It%0D%0Asuccessfully+monitors+and+controls+loads+by+switching+the+load+when+phase+current%0D%0Aimbalance+occurs.+The+comparison+of+power+readings+between+the+monitoring%0D%0Asystem+and+the+measuring+instrument+shows+a+current+error+of+0.077%25+and+a+voltage%0D%0Aerror+of+0.002%25.+When+an+imbalance+exceeds+the+specified+standard%2C+the+system+can%0D%0Aperform+a+load+switching%2C+ensuring+that+the+phase+current+imbalance+meets+the%0D%0Aspecified+standard.+This+is+beneficial+for+the+equipment+and+loads+used.%0D%0AKeywords%3A+Monitoring+and+Control%2C+Phase+Imbalance%2C+Internet+of+Things.&rft.publisher=FAKULTAS+TEKNIK&rft.date=2024-01-17&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F79062%2F1%2FABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F79062%2F2%2FSKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F79062%2F3%2FSKRIPSI%2520TANPA%2520BAB%2520PEMBAHASAN.pdf&rft.identifier=++MUCHLAS+%2C+AL+MA%E2%80%99RUF+++(2024)+MONITORING+DAN+KONTROL+KETIDAKSEIMBANGAN+ARUS+FASA+PADA+SISTEM+DISTRIBUSI+BERBASIS+INTERNET+OF+THINGS+(IoT).++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F79062%2F