creators_name: Ichsanul , Abidin creators_id: 2015021005 type: other datestamp: 2025-02-05 08:25:34 lastmod: 2025-02-05 08:25:34 metadata_visibility: show title: Perancangan Sistem Pendingin Kapasitas 42,21 kg/jam Tipe Water jacket Pada Reaktor Torefaksi Skala Pilot ispublished: pub subjects: 620 full_text_status: restricted abstract: Cooling char ini Bertujuan untuk menurunkan suhu dari biochar yang telah ditorefaksi dan menurunkan titik didihnya agar tidak langsung terbakar setelah ditorefaksi, menghitung spesifikasi dan parameter pada sistem pendinginan yang dibutuhkan, menganalisa heat loss dari reaktor torefaksi menuju cooling char, serta melakukan perancangan terhadap sistem pendingin dari reaktor torefaksi biomassa dengan sistem cooling char menggunakan screw. Metode yang digunakan dalam merancang cooling char yaitu mencari referensi dari buku dan jurnal terkait dengan perhitungan dimensi, Analisa perpindahan panas dan heat loss dari dimensi yang telah dirancang berdasarkan hasil perhitungan mekanikal, menghitung kebutuhan energi, dan mencari ukuran dimensi silinder cooling char yang berada dipasar dan mendekati dengan hasil perhitungan, serta merancang hasil dari perhitungan kedalam bentuk model 3D. Hasil dari penelitian ini yaitu parameter hasil perhitungan dimensi cooling char dengan Panjang 2,414 m, Diameter cooling char 508 mm, Diameter screw 482,82 mm, jarak pitch 241,4 mm, kapasitas cooling char 42,21 kg/jam, , ṁ air = 0,346 kg/s dan ṁ cond= 0,038 kg/s. Serta model 3D yang telah dirancang berdasarkan dengan hasil perhitungan yang telah dilakukan. Kesimpulan dengan adanya sistem pendinginan pada proses torefaksi dapat membuat produk tidak terbakar karena telah didinginkan dibawah titik nyala api, mengetahui nilai spesifikasi dan parameter berdasarkan hasil yang didapat, serta hasil analisa heat loss yaitu Qloss = 0,356 KW, dan membuat perancangan model 3D dari hasil perhitungan cooling char. Kata kunci: Cooling char, Screw, Torefaksi, Heat Loss, Perancangan. This cooling char aims to reduce the temperature of the biochar, Calculate the specifications and parameters of the required cooling system, Analyse the heat loss, and design the cooling system. The method used in designing cooling char is to find references from books and journals, analyse heat transfer and heat loss from the dimensions, calculate energy requirements, and find the dimensions cooling char cylinder that are in the market and close to the calculation, and design the results into a 3D model. The results of this study are the parameters with a length of 2.414 m, cooling char diameter of 508 mm, screw diameter of 482.82 mm, pitch distance of 241.4 mm, cooling char capacity of 42.21 kg / hour, ṁ air = 0.346 kg/s and ṁ cond= 0.038 kg/s. As well as 3D models that have been designed based on the results of mechanical calculations. As well 3D models that have been designed based on the results of calculations. The conclusion with the cooling system in the torefaction process can make the product not burn because it has been cooled, knowing the value of specifications and parameters, as well as the results of heat loss analysis, Qloss = 0.356 KW, and making a 3D model design from the calculation of cooling char. Keywords: Cooling char, Screw, Torefaction, Heat Loss, Design. date: 2024-08-08 date_type: published publisher: TEKNIK place_of_pub: UNIVERSITAS LAMPUNG citation: Ichsanul , Abidin (2024) Perancangan Sistem Pendingin Kapasitas 42,21 kg/jam Tipe Water jacket Pada Reaktor Torefaksi Skala Pilot. TEKNIK, UNIVERSITAS LAMPUNG. document_url: http://digilib.unila.ac.id/82229/1/Full%20Skripsi%20Ichsanul%20Abidin_2015021005%20-%20Ichsanul%20Abidin.pdf document_url: http://digilib.unila.ac.id/82229/1/ABSTRAK%20Skripsi_Ichsanul%20Abidin_2015021005%20-%20Ichsanul%20Abidin.pdf document_url: http://digilib.unila.ac.id/82229/2/Skripsi%20Ichsanul%20Abidin_2015021005%28Tanpa%20Pembahasan%29%20-%20Ichsanul%20Abidin.pdf