?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=RANCANG+BANGUN+SISTEM+PENDETEKSI+DINI+HENTI+JANTUNG%0D%0A%0D%0ADAN+LOKASI+PASIEN+BERBASIS+ARDUINO&rft.creator=ADHIVA+%2C+NUR+FADHEELA&rft.subject=000+Ilmu+komputer%2C+informasi+dan+pekerjaan+umum&rft.subject=600+Teknologi+(ilmu+terapan)&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Henti+jantung+adalah+suatu+kondisi+medis+serius+dimana+jantung+berhenti+berdetak%0D%0Asecara+tiba-tiba.+Secara+khusus%2C+henti+jantung+terjadi+karena+adanya+gangguan%0D%0Apada+sistem+listrik+jantung+yang+mengakibatkan+jantung+tidak+mampu+melakukan%0D%0Akontraksi+secara+efektif+untuk+memompa+darah+ke+seluruh+tubuh.+Meskipun+siapa%0D%0Asaja+dapat+mengalami+henti+jantung%2C+terdapat+beberapa+kelompok+dengan+risiko%0D%0Alebih+tinggi.+Penelitian+ini+bertujuan+mengembangkan+solusi+yang+tidak+hanya%0D%0Aefektif+dalam+mendeteksi+gejala-gejala+awal+henti+jantung%2C+tetapi+juga%0D%0Amenyediakan+informasi+akurat+dan+cepat+kepada+keluarga+pasien+dengan%0D%0Amengirimkan+lokasi+pasien.+Secara+fungsional%2C+komponen-komponen+dalam%0D%0Asistem+ini+berhasil+terintegrasi+dengan+baik%2C+sehingga+memungkinkan+sensor%0D%0Adenyut+jantung%2C+modul+GPS%2C+modul+GSM%2C+dan+buzzer+mengirimkan+informasi.%0D%0ASistem+ini+memiliki+akurasi+detak+jantung+mencapai+98%2C78%25+dan+akurasi+sistem%0D%0Asecara+keseluruhan+mencapai+85%25.+Untuk+penelitian+selanjutnya%2C+disarankan%0D%0Amenggunakan+komponen+yang+lebih+unggul%2C+seperti+sensor+detak+jantung+yang%0D%0Alebih+baik+untuk+penyaringan+noise+yang+lebih+efektif+dan+modul+GPS+berkualitas%0D%0Atinggi+untuk+meningkatkan+akurasi.+Penambahan+LCD+untuk+pemantauan+detak%0D%0Ajantung+juga+dapat+meningkatkan+kualitas+sistem.%0D%0A%0D%0AKata+kunci%3A+Henti+Jantung%2C+Sensor+Pulse+Heart+Rate%2C+Lokasi+Pasien.%0D%0A%0D%0A%0D%0ACardiac+arrest+is+a+serious+medical+condition+where+the+heart+suddenly+stops%0D%0Abeating.+Specifically%2C+cardiac+arrest+occurs+due+to+a+disruption+in+the+heart's%0D%0Aelectrical+system%2C+causing+the+heart+to+be+unable+to+contract+effectively+and+pump%0D%0Ablood+throughout+the+body.+Although+anyone+can+experience+cardiac+arrest%2C%0D%0Acertain+groups+are+at+higher+risk.+This+research+aims+to+develop+a+solution+that+is%0D%0Anot+only+effective+in+detecting+early+symptoms+of+cardiac+arrest+but+also+provides%0D%0Aaccurate+and+rapid+information+to+the+patient's+family+by+sending+the+patient's%0D%0Alocation.+Functionally%2C+the+components+of+this+system+are+successfully+integrated%2C%0D%0Aallowing+the+heart+rate+sensor%2C+GPS+module%2C+GSM+module%2C+and+buzzer+to+send%0D%0Ainformation.+The+system+achieved+a+heart+rate+accuracy+of+98.78%25+and+an+overall%0D%0Asystem+accuracy+of+85%25.+For+future+research%2C+it+is+recommended+to+use+more%0D%0Aadvanced+components%2C+such+as+a+more+sophisticated+heart+rate+sensor+for+better%0D%0Anoise+filtering+and+a+high-quality+GPS+module+to+improve+accuracy.+Adding+an%0D%0ALCD+for+heart+rate+monitoring+may+also+enhance+the+system's+quality.%0D%0A%0D%0AKeywords%3A+Cardiac+Arrest%2C+Pulse+Heart+Rate+Sensor%2C+Patient+Location.&rft.publisher=UNIVERSITAS+LAMPUNG&rft.date=2024-09-12&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F82641%2F1%2F1.%2520ABSTRAK%2520-%2520ABSTRACT%2520-%2520Adhiva%2520Nur%2520Fadheela.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F82641%2F2%2F2.%2520SKRIPSI%2520FULL%2520-%2520Adhiva%2520Nur%2520Fadheela.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F82641%2F3%2F3.%2520SKRIPSI%2520TANPA%2520BAB%2520PEMBAHASAN%2520-%2520Adhiva%2520Nur%2520Fadheela.pdf&rft.identifier=++ADHIVA+%2C+NUR+FADHEELA++(2024)+RANCANG+BANGUN+SISTEM+PENDETEKSI+DINI+HENTI+JANTUNG+DAN+LOKASI+PASIEN+BERBASIS+ARDUINO.++UNIVERSITAS+LAMPUNG%2C+FAKULTAS+TEKNIK.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F82641%2F