?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=IDENTIFIKASI+KERENTANAN+GEDUNG+BALAI+BESAR%0D%0AMETEOROLOGI+KLIMATOLOGI+DAN+GEOFISIKA+WILAYAH+III%0D%0ADENPASAR+DENGAN+METODE+HORIZONTAL+TO+VERTICAL%0D%0A%0D%0ASPECTRAL+RATIO+(HVSR).%0D%0A&rft.creator=Mozalia+%2C+Nanda+Purnama+Putri&rft.subject=620+Ilmu+teknik+dan+ilmu+yang+berkaitan&rft.description=Penelitian+ini+mengkaji+kerentana+gedung+di+Balai+Besar+Meteorologi+Klimatologi%0D%0Adan+Geofisika+Wilayah+III+Denpasar%2C+dengan+menggunakan+data+mikrotremor%0D%0Adimana+pengukuran+dilakukan+pada+basemen%2C+lantai+1%2C+lantai+2%2C+dan+lantai+3.+Pada%0D%0Apenelitian+menggunakan+metode+horizontal+to+vertical+spectral+ratio+(HVSR)+yang%0D%0Abertujuan+untuk+mengidentifikasikan+kerentanan+gedung+dan+resonansi.+Hasil+dari%0D%0Apengolahan+data+mikrotremor+yang+dilakukan+di+software+geopsy+adalah+grafik%0D%0Ahubungan+nilai+H%2FV+dan+frekuensi%2C+dari+grafik+tersebut+akan+diperoleh+nilai%0D%0Afrekuensi+dominan+(f0)+dan+nilai+amplitudo+dominan+(A0)+pada+tiap+titik%0D%0Apengukurannya.+Kemudian+mendapat+hasil+resonansi+yang+tidak+jauh+berbeda%0D%0Apada+setiap+lantainya.+Hasil+resonansi+yang+didapatkan+berkisaran+dari+32%2C1%25%0D%0Asampai+67%2C46%25+dimana+berdasarkan+klasifikasi+merupakan+termasuk+tingkat%0D%0Aresonansi+rendah.+Dimana+lantai+2+merupakan+lantai+yang+lebih+rentan+terhadap%0D%0Agempa+bumi+dikarenakan+nilai+indeks+kerentanan+yang+dimiliki+lebih+tinggi%0D%0Adibandingkan+dengan+lantai+lainnya.+Oleh+karena+itu%2C+penelitian+ini+memberikan%0D%0Akontribusi+dalam+memahami+kerentanan+gedung+di+daerah+studi+dan+dapat+menjadi%0D%0Adasar+untuk+pengelolaan+risiko+bencana+di+masa+depan.%0D%0A%0D%0AKata+Kunci+%3A+Mikrotremor%2C+resonansi%2C+kerentanan+gedung.%0D%0A%0D%0Aii%0D%0AABSTRACT%0D%0A%0D%0AIDENTIFICATION+OF+VULNERABILITY+OF+REGIONAL+METEOROLGY%0D%0ACLIMATLOGY+AND+GEOPHYSICS+OFFICE+III+DENPASAR+BUILDING%0D%0AWITH+HORIZONTAL+TO+VERTICAL+SPECTRAL+RATIO+METHOD%0D%0A%0D%0ABy%0D%0A%0D%0AMozalia+Nanda+Purnama+Putri%0D%0A%0D%0AThis+study+investigates+the+vulnerability+of+the+building+at+the+Regional%0D%0AMeteorology+Climatology+and+Geophysics+Office+III+Denpasar%2C+using+microtremor%0D%0Adata+collected+from+the+basement%2C+first+floor%2C+second+floor%2C+and+third+floor.+The%0D%0Astudy+employs+the+horizontal+to+vertical+spectral+ratio+(HVSR)+method+to+identify%0D%0Athe+building's+vulnerability+and+resonance.+The+data+processing+using+geopsy%0D%0Asoftware+produces+graphs+showing+the+relationship+between+H%2FV+values+and%0D%0Afrequency%2C+from+which+the+dominant+frequency+(f0)+and+dominant+amplitude+(A0)%0D%0Avalues+are+obtained+at+each+measurement+point.+The+resonance+results+are%0D%0Aconsistent+across+all+floors%2C+ranging+from+32.1%25+to+67.46%25%2C+indicating+a+low+level%0D%0Aof+resonance.+The+second+floor+is+found+to+be+more+vulnerable+to+earthquakes+due%0D%0Ato+its+higher+vulnerability+index+compared+to+other+floors.+Therefore%2C+this+study%0D%0Acontributes+to+understanding+the+building's+vulnerability+in+the+study+area+and+can%0D%0Aserve+as+a+basis+for+disaster+risk+management+in+the+future.%0D%0A%0D%0AKeyword+%3A+Microtremor%2C+resonance%2C+vulnerability+building.&rft.publisher=FAKULTAS+TEKNIK&rft.date=2024-05-08&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F83298%2F1%2FABSTRAK%2520MOZALIA%25201715051010%2520-%2520Mozalia%2520Nanda.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F83298%2F2%2FFULL%2520SKRIPSI%2520MOZALIA%25201715051010%2520-%2520Mozalia%2520Nanda.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F83298%2F3%2FTANPA%2520PEMBAHASANA%2520MOZALIA%25201715051010%2520-%2520Mozalia%2520Nanda.pdf&rft.identifier=++Mozalia+%2C+Nanda+Purnama+Putri++(2024)+IDENTIFIKASI+KERENTANAN+GEDUNG+BALAI+BESAR+METEOROLOGI+KLIMATOLOGI+DAN+GEOFISIKA+WILAYAH+III+DENPASAR+DENGAN+METODE+HORIZONTAL+TO+VERTICAL+SPECTRAL+RATIO+(HVSR).++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F83298%2F