?url_ver=Z39.88-2004&rft_id=1815031064+&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=ANALISIS+MANAJEMEN+ENERGI+PADA+GEDUNG+LABORATORIUM%0D%0ATEKNIK+ELEKTRO+UNIVERSITAS+LAMPUNG+&rft.creator=Fikri%2C+Milleniyanto&rft.subject=000+Ilmu+komputer%2C+informasi+dan+pekerjaan+umum&rft.subject=500+ilmu+pengetahuan+alam+dan+matematika&rft.subject=602+Aneka+ragam+tentang+teknologi+dan+ilmu+terapan&rft.description=Efisiensi+energi+pada+gedung+pendidikan+merupakan+faktor+penting+untuk%0D%0Amendukung+keberlanjutan+energi+global.+Gedung+Laboratorium+Teknik+Elektro%0D%0AUniversitas+Lampung+memiliki+luas+1.715%2C95+m%C2%B2+dengan+konsumsi+energi+yang%0D%0Atinggi%2C+terutama+untuk+pencahayaan%2C+pendinginan%2C+dan+peralatan+listrik.+Penelitian%0D%0Aini+bertujuan+untuk+menganalisis+intensitas+konsumsi+energi+(IKE)%2C%0D%0Amengidentifikasi+peluang+penghematan+energi+(PPE)%2C+dan+merekomendasikan%0D%0Astrategi+peningkatan+efisiensi+energi+di+gedung+ini.+Data+dikumpulkan%0D%0Amenggunakan+Power+Quality+Analyzer+(PQA)+untuk+memantau+parameter%0D%0Akelistrikan%2C+seperti+daya+aktif%2C+daya+reaktif%2C+faktor+daya%2C+dan+harmonik.+Hasil%0D%0Apenelitian+menunjukkan+bahwa+intensitas+pencahayaan+di+sebagian+besar+ruangan%0D%0Aberada+di+bawah+standar+SNI+6197%3A2011%2C+dengan+nilai+tertinggi+hanya+278+lux+dari%0D%0Astandar+minimum+350%E2%80%93500+lux.+Sistem+pendingin+udara+juga+tidak+optimal%2C%0D%0Amenghasilkan+suhu+ruangan+di+atas+standar+kenyamanan+25%C2%B0C+%C2%B1+1%C2%B0C.+Analisis%0D%0Akelistrikan+mengungkapkan+distribusi+beban+yang+tidak+merata+dan+faktor+daya%0D%0Amendekati+0%2C95%2C+yang+masih+memerlukan+optimalisasi.+Potensi+penghematan+energi%0D%0Ateridentifikasi+melalui+penggantian+lampu+konvensional+dengan+LED%2C+perbaikan%0D%0Asistem+pendingin+udara%2C+dan+pemasangan+kapasitor+bank+untuk+memperbaiki+faktor%0D%0Adaya.+Rekomendasi+penelitian+mencakup+strategi+manajemen+energi+berbasis+data%0D%0Auntuk+meningkatkan+efisiensi+tanpa+mengurangi+kenyamanan+pengguna.%0D%0AImplementasi+strategi+ini+diharapkan+dapat+mengurangi+pemborosan+energi%2C%0D%0Amenurunkan+biaya+operasional%2C+dan+menjadi+model+pengelolaan+energi%0D%0Aberkelanjutan+di+institusi+pendidikan.+%0D%0AKata+Kunci%3A+Efisiensi+Energi%2C+Intensitas+Konsumsi+Energi%2C+Audit+Energi%2C+Power%0D%0AQuality+Analyzer.+%0D%0A%0D%0AEnergy+efficiency+in+educational+buildings+is+a+crucial+factor+in+supporting+global%0D%0Aenergy+sustainability.+The+Electrical+Engineering+Laboratory+Building+at+the%0D%0AUniversity+of+Lampung%2C+with+an+area+of+1%2C715.95+m%C2%B2%2C+has+high+energy+consumption%2C%0D%0Aparticularly+for+lighting%2C+cooling%2C+and+electrical+equipment.+This+study+aims+to%0D%0Aanalyze+energy+consumption+intensity+(IKE)%2C+identify+energy-saving+opportunities%0D%0A(PPE)%2C+and+recommend+strategies+to+improve+energy+efficiency+in+this+building.%0D%0AData+was+collected+using+a+Power+Quality+Analyzer+(PQA)+to+monitor+key+electrical%0D%0Aparameters+such+as+active+power%2C+reactive+power%2C+power+factor%2C+and+harmonics.%0D%0AThe+results+show+that+lighting+intensity+in+most+rooms+is+below+the+SNI+6197%3A2011%0D%0Astandard%2C+with+the+highest+value+reaching+only+278+lux+compared+to+the+minimum%0D%0Astandard+of+350%E2%80%93500+lux.+The+air+conditioning+system+is+also+suboptimal%2C+resulting%0D%0Ain+room+temperatures+exceeding+the+comfort+standard+of+25%C2%B0C+%C2%B1+1%C2%B0C.+Electrical%0D%0Aanalysis+reveals+uneven+load+distribution+and+a+power+factor+of+approximately+0.95%2C%0D%0Awhich+still+requires+optimization.+Energy-saving+potential+was+identified+through%0D%0Areplacing+conventional+lighting+with+LED%2C+improving+the+air+conditioning+system%2C%0D%0Aand+installing+capacitor+banks+to+enhance+the+power+factor.+This+study+recommends%0D%0Aa+data-driven+energy+management+strategy+to+improve+efficiency+without%0D%0Acompromising+user+comfort.+The+implementation+of+these+strategies+is+expected+to%0D%0Areduce+energy+waste%2C+lower+operational+costs%2C+and+serve+as+a+model+for+sustainable%0D%0Aenergy+management+in+educational+institutions.+%0D%0AKeywords%3A+Energy+Efficiency%2C+Energy+Consumption+Intensity%2C+Energy+Audit%2C+Power%0D%0AQuality+Analyzer.&rft.publisher=FAKULTAS+TEKNIK&rft.date=2025-01-24&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F84967%2F1%2FABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F84967%2F2%2FSKRIPSI%2520FULL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F84967%2F3%2FSKRIPSI%2520FULL%2520TANPA%2520PEMBAHASAN.pdf&rft.identifier=++Fikri%2C+Milleniyanto++(2025)+ANALISIS+MANAJEMEN+ENERGI+PADA+GEDUNG+LABORATORIUM+TEKNIK+ELEKTRO+UNIVERSITAS+LAMPUNG.++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F84967%2F