?url_ver=Z39.88-2004&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Adc&rft.title=PERBANDINGAN+KARAKTERISTIK+PELUAHAN+SEBAGIAN+(PARTIAL+DISCHARGE)+PADA+ISOLASI+EPOKSI+RESIN+(RESIN+EPOXY)++TERHADAP+KARET+SILIKON+(SILICONE+RUBBER)+MENGGUNAKAN+SENSOR+EMISI+AKUSTIK&rft.creator=DERRY+FERDIANSYAH%2C+1015031030&rft.subject=Teknik+Elektro.+Rekayasa+elektronik+Nuklir&rft.description=ABSTRAK%0D%0A%0D%0ASistem+isolasi+sangat+penting+untuk+menentukan+kondisi+peralatan+tegangan+tinggi.+Salah+satu+pengujian+terhadap+kondisi+sistem+isolasi+adalah+dengan+pengukuran+peluahan+sebagian.+Akan+tetapi+kebanyakan+penelitian+peluahan+sebagian+yang+telah+diterapkan+adalah+bersifat+merusak+material+isolasi+yang+diuji%2C+oleh+karena+itu+dalam+penelitian+ini+dilakukan+pengujian+peluahan+sebagian+dengan+metode+Emisi+Akustik+yang+tidak+merusak+material+isolasi+(Non-Destructive+Testing).%0D%0A%0D%0APada+metode+emisi+akustik+ini+digunakan+sensor+emisi+akustik+untuk+menangkap+gelombang+elastis+yang+dikeluarkan+oleh+material.+Penelitian+ini+dilakukan+dengan+membandingkan+karakteristik+peluahan+sebagian+antara+epoksi+resin+dan+karet+silikon.+Karakteristik+peluahan+sebagian+itu+meliputi+tegangan+kritis%2C+frekuensi+dominan%2C+arus+bocor%2C+dan+waktu+sampai+terjadinya+peluahan+sebagian.%0D%0A%0D%0ADari+hasil+pengujian+diketahui+bahwa+frekuensi+dominan+peluahan+sebagian+dari+epoksi+resin+lebih+besar+dari+karet+silikon.+Tegangan+uji+pada+epoksi+resin+rata-rata+lebih+besar+dari+karet+silikon+(1.5-1.7+kV+dan+1.0-1.2+KV)%2C+waktu+sampai+terjadinya+peluahan+sebagian+pada+epoksi+resin+lebih+lama+dari+karet+silikon+%0D%0A(31-35+menit+dan+28-33+menit)%2C+sedangkan+karet+silikon+lebih+efektif+dalam+mereduksi+arus+bocor+(28-34+mA)+dibandingkan+epoksi+resin+(42-48+mA).%0D%0A%0D%0A%0D%0AKata+Kunci%3A+Peluahan+Sebagian%2C+Emisi+Akustik%2C+Epoksi+Resin%2C+Karet+Silikon%2C++Frekuensi+Dominan.%0D%0A%0D%0A%0D%0A%0D%0AABSTRACT%0D%0A%0D%0A%0D%0A%0D%0AInsulation+system+is+essential+to+determine+the+condition+of+high+voltage+equipment.+One+of+the+conditions+insulation+system+testing+is+the+partial+discharge+testing.+However%2C+most+studies+that+have+applied+partial+discharge+constrains+destructive+testing+insulation+material%2C+therefore+the+partial+discharge+testing+in+this+research+is+using+Acoustic+Emission+method+which+does+not+damage+the+material+insulation+(Non-Destructive+Testing).%0D%0A%0D%0AIn+the+acoustic+emission+method+is+used+Acoustic+Emission+Sensors+to+capture+the+elastic+waves+that+released+by+material%2C+This+research+is+done+by+comparing+the+characteristics+of+the+partial+discharge+between+resin+epoxy+and+silicone+rubber+insulation.+The+partial+discharge+characteristics+include+critical+voltage%2C+dominant+frequency%2C+leakage+current%2C+and+the+duration+until+the+occurrence+of+partial+discharge.+%0D%0A%0D%0AFrom+the+results%2C+it+is+known+that+the+dominant+frequency+partial+discharge+of+the+epoxy+resin+is+larger+than+silicone+rubber.+Epoxy+resin+test+voltage+on+average+larger+than+silicone+rubber+(kV+1.5-1.7+and+1.0-1.2+KV)%2C+duration+until+the+occurrence+of+partial+discharge+in+the+epoxy+resin+longer+than+silicone+rubber+(31-35+minutes+and+28-33+minutes)%2C+whereas+the+silicone+rubber+is+more+effective+in+reducing+leakage+current+(28-34+mA)+than+epoxy+resin+(42-48+mA)%0D%0A%0D%0A%0D%0AKey+Words+%3A+Partial+Discharge%2C+Acoustic+Emission%2C+Resin+Epoxy%2C+Silicone+Rubber%2C+Dominant+Frequency.%0D%0A%0D%0A%0D%0A%0D%0A&rft.publisher=FAKULTAS+TEKNIK&rft.date=2015-04-20&rft.type=Skripsi&rft.type=NonPeerReviewed&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F1%2F1-%2520ABSTRAK.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F2%2F2-%2520ABSTRACT.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F3%2F3-%2520COVER%2520DALAM.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F4%2F4-%2520PERSETUJUAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F5%2F5-%2520PENGESAHAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F6%2F6-%2520PERNYATAAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F7%2F7-%2520RIWAYAT%2520HIDUP.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F8%2F8-%2520PERSEMBAHAN.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F9%2F9-%2520MOTO.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F10%2F10-%2520SANWACANA.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F12%2F12-%2520DAFTAR%2520GAMBAR.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F13%2F13-%2520DAFTAR%2520TABEL.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F124%2FDAFTAR%2520ISI.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F14%2F14-%2520BAB%2520I.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F125%2FBAB%2520II.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F16%2F16-%2520BAB%2520III.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F126%2FBAB%2520IV.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F18%2F18-%2520BAB%2520V.pdf&rft.format=text&rft.identifier=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F19%2F19-%2520DAFTAR%2520PUSTAKA.pdf&rft.identifier=++DERRY+FERDIANSYAH%2C+1015031030++(2015)+PERBANDINGAN+KARAKTERISTIK+PELUAHAN+SEBAGIAN+(PARTIAL+DISCHARGE)+PADA+ISOLASI+EPOKSI+RESIN+(RESIN+EPOXY)+TERHADAP+KARET+SILIKON+(SILICONE+RUBBER)+MENGGUNAKAN+SENSOR+EMISI+AKUSTIK.++FAKULTAS+TEKNIK%2C+UNIVERSITAS+LAMPUNG.+++++&rft.relation=http%3A%2F%2Fdigilib.unila.ac.id%2F9540%2F