Digital Library: No conditions. Results ordered -Date Deposited. 2024-03-29T15:43:33ZEPrintshttp://digilib.unila.ac.id/images/sitelogo.pnghttp://digilib.unila.ac.id/2022-05-23T03:57:41Z2022-05-23T03:57:41Zhttp://digilib.unila.ac.id/id/eprint/24404This item is in the repository with the URL: http://digilib.unila.ac.id/id/eprint/244042022-05-23T03:57:41ZSISTEM ONLINE MONITORING BESARAN LISTRIK 3 FASA
BERBASIS SINGLE BOARD COMPUTER BCM 2835Besaran listrik 3 fasa perlu dimonitor untuk mengetahui nilai besaran listriknya
tegangan (V), arus (A), faktor daya (Cos θ), daya (W) dan konsumsi energi
(kWh). Sehingga dapat diketahui untuk mengetahui kualitas pasokan energi
listriknya.
Sistem monitoring yang dimaksud pada tugas akhir ini adalah pengukuran
tegangan dan arus sedangkan nilai daya dan faktor daya didapat dari hasil
perhitungan menggunakan program bahasa C yang di arduino sedangkan untuk
perhitungan konsumsi energi/kWh dibuat pemograman python pada Single Board
Computer BCM 2835.
Sebuah prototype sistem monitoring telah diujikan pada gedung Laboratorium
Jurusan Teknik Elektro dan gedung UPT - TIK Universitas Lampung. Dari data
yang diperoleh pada tanggal 30 juni 2016 didapat hasil nilai besaran listrik antar
phasa: tegangan, arus dan daya pada ke dua gedung cenderung tidak seimbang,
hal ini disebabkan karena pola pembebanan masing-masing phasa pada gedung
yang dianalisa tidak merata. Sedangkan untuk nilai faktor daya pada setiap
gedungnya bergantung pada beban.
Kata kunci : listrik 3 fasa, sensor tegangan, sensor arus, Arduino, Single
board Computer BCM 2835.
ABSTRACT
Three phase electrical quantities need to be monitored for determine the value of
the electrical voltage (V), current (A), power factor (cos θ), power (W) and energy
consumption (kWh). So that can be inform the quality of the electrical energy
supply.
Monitoring system in this final project describe the measurement of voltage and
current while the power and power factor value obtained from the calculation
using the C language program at arduino where as for the calculation of energy
consumption / kWh made by python programming at BCM 2835.
The prototype for monitoring system that has been done at the laboratory and
Department of Electrical Engineering Unit – ICT buildings, University of
Lampung. From the data obtained on 30 June 2016 the results of the inter-phase
electrical quantities: voltage, current and power on to the two buildings tend to be
unbalanced, because the loading pattern of each phase in the building which
analyzed was unbalance. For the value of the power factor at every building is
depends on the load.
Keywords: 3 phase electrical, voltage sensors, flow sensors, Arduino, Single
board Computers BCM 8235.0745031043 YUSUF YOEKIE PERMADI yupermadi0@gmail.com