PENGARUH LIMA TAHAPAN PENGUJIAN TERHADAP MODUL FOTOVOLTAIK BERDASARKAN SNI IEC 61215:2016 DI LABORATORIUM PENGUJIAN FOTOVOLTAIK

NA’IMAH , KHOIRIYAH (2025) PENGARUH LIMA TAHAPAN PENGUJIAN TERHADAP MODUL FOTOVOLTAIK BERDASARKAN SNI IEC 61215:2016 DI LABORATORIUM PENGUJIAN FOTOVOLTAIK. FAKULTAS MATEMATIKA DAN ILMU PENGETAHUAN ALAM, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
(DIGILIB) Abstrak_Naimah Khoiriyah - Naimah Khoiriyah.pdf

Download (232Kb) | Preview
[img] File PDF
(DIGILIB) FULL SKRIPSI - Naimah Khoiriyah.pdf
Restricted to Hanya staf

Download (2715Kb) | Minta salinan
[img]
Preview
File PDF
(DIGILIB) Perbaikan File FULL SKRIPSI Tanpa Pembahasan - Naimah Khoiriyah.pdf

Download (2426Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Penelitian ini telah dilakukan dengan menggunakan sebanyak sepuluh modul fotovoltaik. Dengan menggunakan sun simulator sebagai alat utama yang bertujuan untuk mengevaluasi pengaruh yang terjadi pada lima tahapan pengujian lingkungan pada degradasi daya maksimum (Pmax) terhadap modul fotovoltaik berdasarkan SNI IEC 61215:2016. Metode yang dilakukan dalam penelitian ini berupa pengujian modul fotovoltaik, pengumpulan data, analisis dan pengolahan data. Evaluasi dilakukan setelah seluruh tahapan selesai atau pada pengujian akhir, dengan menganalisis nilai daya maksimum (Pmax) dan membandingkannya terhadap degradasi kinerja sebesar kurang dari 5% yang telah ditentukan standar. Hasil menunjukkan bahwa beberapa modul mengalami penurunan daya, namun masih dalam ambang batas yang ditetapkan SNI IEC 61215:2016. Namun, pada tahapan D yaitu uji siklus termal, ditemukan degradasi sebesar 5,86%, yang melampaui nilai ambang batas dan menunjukkan bahwa modul tersebut gagal memenuhi kriteria kelulusan. Dengan demikian, hasil penelitian ini menunjukkan bahwa pengujian pada tahapan D, memiliki pengaruh yang signifikan terhadap penurunan kinerja modul fotovoltaik, sehingga perlu menjadi perhatian khusus dalam uji kualifikasi untuk memastikan kestabilan modul sebelum dipasang dilapangan. Kata Kunci : Daya Maksimum (Pmax), Degradasi, Modul Fotovoltaik, SNI IEC 61215, Standar Test Condition (STC) This research has been conducted using ten photovoltaic modules. By using a sun simulator as the main tool that aims to evaluate the effects that occur in the five stages of environmental testing on the maximum power degradation (Pmax) of photovoltaic modules based on SNI IEC 61215:2016. The methods used in this research are photovoltaic module testing, data collection, analysis and data processing. Evaluation is carried out after all stages are completed or at the final test, by analyzing the maximum power value (Pmax) and comparing it to the performance degradation of less than 5% that has been determined by the standard. The results show that some modules experienced a decrease in power, but still within the threshold set by SNI IEC 61215:2016. However, in stage D, namely the thermal cycle test, a degradation of 5.86% was found, which exceeds the threshold value and indicates that the module failed to meet the passing criteria. Thus, the results of this study indicate that testing in stage D has a significant influence on the decline in the performance of photovoltaic modules, so it needs to be given special attention in qualification tests to ensure the stability of the module before being installed in the field. Keyword : Degradation, Maximum Power (Pmax), Photovoltaic Module, SNI IEC 61215, Standar Test Condition (STC)

Jenis Karya Akhir: Skripsi
Subyek: 500 ilmu pengetahuan alam dan matematika
500 ilmu pengetahuan alam dan matematika > 530 Fisika
Program Studi: FAKULTAS MATEMATIKA DAN ILMU PENGETAHUAN ALAM (FMIPA) > Prodi S1 Fisika
Pengguna Deposit: A.Md Cahya Anima Putra .
Date Deposited: 29 Jan 2026 07:44
Terakhir diubah: 29 Jan 2026 07:44
URI: http://digilib.unila.ac.id/id/eprint/95261

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir