Alat Pengukur Kapasitansi Berbasis Phase-Sensitive Demodulation (PSD) untuk Sensor ECVT

Muhamad Aji Hilmi Anugrah, 1115031057 (2015) Alat Pengukur Kapasitansi Berbasis Phase-Sensitive Demodulation (PSD) untuk Sensor ECVT. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
01 Abstrak.pdf

Download (110Kb) | Preview
[img]
Preview
File PDF
02 Abstract-Bahasa inggris.pdf

Download (109Kb) | Preview
[img]
Preview
File PDF
03 Cover Dalam.pdf

Download (39Kb) | Preview
[img]
Preview
File PDF
04 Hlm. Persetujuan.pdf

Download (1038Kb) | Preview
[img]
Preview
File PDF
05 Hlm. Pengesahan.pdf

Download (757Kb) | Preview
[img]
Preview
File PDF
06 Pernyataan.pdf

Download (425Kb) | Preview
[img]
Preview
File PDF
07 Riwayat Hidup.pdf

Download (100Kb) | Preview
[img]
Preview
File PDF
08 Persembahan.pdf

Download (153Kb) | Preview
[img]
Preview
File PDF
09 Motto.pdf

Download (159Kb) | Preview
[img]
Preview
File PDF
10 Sanwacana.pdf

Download (274Kb) | Preview
[img]
Preview
File PDF
12 Daftar Tabel.pdf

Download (188Kb) | Preview
[img]
Preview
File PDF
13 Daftar Lampiran.pdf

Download (85Kb) | Preview
[img]
Preview
File PDF
14 Daftar Gambar.pdf

Download (330Kb) | Preview
[img]
Preview
File PDF
11 Daftar Isi.pdf

Download (201Kb) | Preview
[img]
Preview
File PDF
Bab 1.pdf

Download (210Kb) | Preview
[img]
Preview
File PDF
Bab 2.pdf

Download (658Kb) | Preview
[img]
Preview
File PDF
Bab 3.pdf

Download (880Kb) | Preview
[img] File PDF
Bab 4.pdf
Restricted to Hanya pengguna terdaftar

Download (1069Kb)
[img]
Preview
File PDF
Bab 5.pdf

Download (109Kb) | Preview
[img]
Preview
File PDF
Daftar Pustaka.pdf

Download (112Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Abstrak Electrical Capacitance Volume Tomography (ECVT) mampu melakukan rekonstruksi gambar sesuai nilai konstanta dielektrik yang ada di dalam sensor. ECVT memiliki tiga bagian utama, pertama sensor kapasitansi, kedua sistem akuisisi data, terakhir komputer untuk kontrol dan mengolah gambar. Bagian terpenting adalah sistem akuisisi data. Di dalamnya ada rangkaian pengukur kapasitansi Phase-Sensitive Demodulation (PSD). PSD memiliki lima tahapan sistem. Pertama, AC-Based. Kedua, Inverting Amplifier. Ketiga, Phase Shifter. Keempat, Analog Multiplier. Kelima Low-Pass Filter (LPF). Metode untuk penelitian ini dilakukan dalam lima tahap. Pertama simulasi menggunakan PSpice. Kedua melakukan analisis daerah kerja, kelinieran, resolusi, Mean Absolut Error (MAE), dan kondisi termal dari hasil simulasi. Ketiga Eksperimen alat akan diuji dengan kapasitor 1pF -- 15pF kenaikan 1pF. Keempat Analisis perbandingan hasil simulasi dan eksperimen. Kelima pengujian Alat dengan sensor ECVT. Hasil dari penelitian ini ada tiga. Pertama adalah karakteristik dari sistem. Daerah kerja sistem ≥500fF, kelinieran y=1,0297x-79,884x1015, R2=0,9999, resolusi 0,90mV/fF, MAE 0,158pF, kondisi termal pada suhu -25oC -- 125oC tegangan keluaran mengalami perubahan rata-rata 4,36mV. Kedua adalah hasil simulasi dan eksperimen sebanding, eror simulasi 2,23% dan eror eksperimen 3,87%. Ketiga adalah alat mampu mengukur perbedaan kapasitansi sensor ECVT dalam kondisi kosong, penuh dengan air dan berisi limbah minyak kelapa sawit. Abstract Electrical Capacitance Volume Tomography (ECVT) can perform image reconstruction corresponding dielectric constant value that is in the sensor. ECVT has three main parts, the first capacitance sensor, the data acquisition system, the last computer to control and process images. The most important part is the data acquisition system. In it there is a capacitance measuring circuit. The capacitance measuring circuit using Phase-Sensitive Demodulation (PSD). PSD has five stages of the system. First, AC-Based. Secondly, Inverting Amplifier. Third, Phase Shifter. Fourth, Analog Multiplier. Fifth Low-Pass Filter (LPF). Methods of research carried out in five stages. The first simulation using PSpice. The second work area analysis, linearity, resolution, Mean Absolute Error (MAE), and thermal conditions of the simulation results. The third experiment will be tested by 1pF to 15pF capacitor with 1pF increase. The fourth comparative analysis of simulation results and experimental. The fifth test experiments with sensor ECVT. There are three research. The first is the characteristics of the system. The work area system is ≥ 500fF, the linearity is y = 1,0297x-79,884x1015, R2 = 0.9999, The resolution 0,90 mV/fF, The MAE 0,158pF, The thermal conditions at a temperature of -25 oC -- 125 oC with increases 5 oC, the changing output voltage average is 4, 36mV. The second is the simulation and experimental results are comparable, the simulation error of 2.23% and the experimental error of 3.87%. The third is PSD circuit have a capable of measuring the difference in the capacitance sensor ECVT in an empty condition, filled with water and containing palm oil waste.

Jenis Karya Akhir: Skripsi
Subyek: > Teknik Elektro. Rekayasa elektronik Nuklir
> Teknik Elektro. Rekayasa elektronik Nuklir
Program Studi: Fakultas Teknik > Prodi S1-Teknik Elektro
Pengguna Deposit: 5033534 . Digilib
Date Deposited: 19 Aug 2015 07:22
Terakhir diubah: 19 Aug 2015 07:22
URI: http://digilib.unila.ac.id/id/eprint/11797

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir