STUDI PENDAHULUAN PENGEMBANGAN METODE ANALISIS NITROGEN DIOKSIDA (NO2) PADA UDARA AMBIEN DENGAN TEKNIK VOLTAMMETRI SIKLIK

0717011057, Refi Indarosa Madya Yanti (2012) STUDI PENDAHULUAN PENGEMBANGAN METODE ANALISIS NITROGEN DIOKSIDA (NO2) PADA UDARA AMBIEN DENGAN TEKNIK VOLTAMMETRI SIKLIK. Digital Library.

[img]
Preview
File PDF
CURRICULUM VITAE.pdf

Download (88Kb) | Preview
[img]
Preview
File PDF
RIWAYAT HIDUP .pdf

Download (14Kb) | Preview
[img]
Preview
File PDF
cover.pdf

Download (15Kb) | Preview
[img]
Preview
File PDF
ABSTRAK .pdf

Download (18Kb) | Preview
[img]
Preview
File PDF
Motto .pdf

Download (14Kb) | Preview
[img]
Preview
File PDF
PERSEMBAHAN .pdf

Download (20Kb) | Preview
[img]
Preview
File PDF
SANWACANA .pdf

Download (15Kb) | Preview
[img]
Preview
File PDF
bab 1.pdf

Download (23Kb) | Preview
[img]
Preview
File PDF
bab 2.pdf

Download (183Kb) | Preview
[img]
Preview
File PDF
bab 3.pdf

Download (116Kb) | Preview
[img] File PDF
bab 4.pdf
Restricted to Hanya pengguna terdaftar

Download (153Kb)
[img]
Preview
File PDF
bab 5.pdf

Download (14Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Abstrak Telah dilakukan penelitian mengenai analisis Nitrogen Dioksida (NO2) pada udara ambien menggunakan metode voltammetri siklik. NO2 dijerat dalam larutan NaOH menggunakan alat impinger. Gas NO2 yang tertangkap dalam absorben akan terkonversi menjadi NO2- yang kemudian dianalisis menggunakan metode voltammetri siklik. Analisis NO2 dilakukan menggunakan elektroda kerja emas (Au), elektroda bantu Pt dan elektroda acuan Ag/AgCl. Laju scan yang digunakan adalah 100 mV/s dengan interval potensial 0 V sampai 1,4 V. Elektrolit pendukung yang digunakan yaitu NaClO4 0,1 M dan H2SO4 0,3 M. Dari kurva standar didapat koefisien korelasi menggunakan NaClO4 sebesar 0,979 sedangkan menggunakan H2SO4 sebesar 0,882. Penggunaan elektrolit NaClO4 lebih baik daripada elektrolit H2SO4 sehingga elektrolit yang digunakan yaitu elektrolit NaClO4. Hasil penelitian menunjukkan bahwa potensial elektroda standar (E0) pada pengukuran NO2 dalam NaClO4 adalah 1,3 V, limit deteksi 1,262 mM dan konsentrasi NO2 pada ketiga lokasi yaitu 0,765 ± 0,048; 0,261 ± 0,048 dan 0,143 ± 0,048 µg/m3. Berdasarkan hasil tersebut, konsentrasi di masing-masing lokasi masih di bawah standar baku mutu. Kata kunci: pengembangan metode udara ambien, analisis NO2, Voltammetri siklik Abstract Analysis of ambient Nitrogen dioxide (NO2) have done by using cyclic voltammetry technique. NO2 was trapped in NaOH solution in impinger tool. The absorbed gas was converted to NO2- and was analyzed by cyclic voltammetry. The analysis used Au as a working electrode, Pt as an auxiliary electrode and Ag/AgCl as a reference electrode. The scan rate was 100 mV/s and the applied potential was ranged of0 - 1,4 V. H2SO4 0,3 M and NaClO4 0,1 M were used as supporting electrolytes, which had correlation coefficient 0,882 and 0,979 respectively. Because of the better fitness, NaClO4 were used to analyze the sample. It was show that Eo NO2 was 1,3 V and detection limit of this method was 1,262 mM and NO2 concentration for three sampling points were 0,765 ± 0,048 ; 0,261 ± 0,048 dan 0,143 ± 0,048 µg/m 3 (Still below the Indonesian Nasional Ambient Air Quality Standar ). Key word : method development, ambient NO2 analysis, cyclic voltammetry

Jenis Karya Akhir: Artikel
Subyek:
Program Studi: FAKULTAS MIPA > Prodi Kimia
Pengguna Deposit: IC-STAR . 2015
Date Deposited: 22 Oct 2015 08:50
Terakhir diubah: 22 Oct 2015 08:50
URI: http://digilib.unila.ac.id/id/eprint/13181

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir