0717011071, Yanti Lianita (2012) STUDI PENDAHULUAN PENGEMBANGAN METODE ANALISIS NITROGEN DIOKSIDA (NO2) PADA UDARA AMBIEN DENGAN TEKNIK VOLTAMMETRI GELOMBANG PERSEGI (SQUARE WAVE VOLTAMMETRY). Digital Library.
|
Text
cover.pdf Download (22kB) | Preview |
|
|
Text
pengesahan.pdf Download (24kB) | Preview |
|
|
Text
ABSTRACT.pdf Download (12kB) | Preview |
|
|
Text
bab 1 .pdf Download (26kB) | Preview |
|
|
Text
bab 2 .pdf Download (177kB) | Preview |
|
|
Text
bab 3.pdf Download (115kB) | Preview |
|
|
Text
bab 4 .pdf Restricted to Registered users only Download (156kB) |
||
|
Text
bab 5 .pdf Download (8kB) | Preview |
|
|
Text
dapus .pdf Download (16kB) | Preview |
|
|
Text
MENGESAHKAN.pdf Download (7kB) | Preview |
|
|
Text
Motto .pdf Download (13kB) | Preview |
|
|
Text
PERSEMBAHAN .pdf Download (21kB) | Preview |
|
|
Text
RIWAYAT HIDUP .pdf Download (17kB) | Preview |
|
|
Text
sanwacana .pdf Download (15kB) | Preview |
Abstract
Abstrak Pada penelitian ini, telah dilakukan analisis nitrogen dioksida (NO2) pada udara ambien dengan menggunakan voltammetri square wave. Sampel udara dijerap menggunakan alat impinger dengan menggunakan larutan NaOH 0,1M sebagai absorber. Udara yang masuk kemudian terkonversi menjadi ion NO2- yang kemudian dianalisis menggunakan voltammetri square wave. Analisis dilakukan menggunakan elektroda kerja emas, elektroda bantu Pt dan elektroda acuan Ag/AgCl. Elektrolit pendukung yang digunakan yaitu larutan NaClO4 0,1M dan H2SO4 0,3 M, dengan kecepatan scan 100 mV/s. Hasil penelitian menunjukkan bahwa potensial elektroda standar (Eo) pada pengukuran NaNO2 dalam H2SO4 0,3 M adalah sebesar 800 mV, sedangkan NaClO4 0,1M adalah sebesar 1300 mV terhadap Ag/AgCl. Kurva kalibrasi NaNO2 dengan elektrolit H2SO4 0,3M yang dihasilkan menunjukkan kelinearan sebesar 0,992 dan limit deteksinya sebesar 0,02 M. Pada kurva kalibrasi NaNO2 dengan elektrolit NaClO4 0,1 M yang dihasilkan menunjukkan kelinearan dengan koefisien korelasi sebesar 0,956 dan limit deteksinya sebesar 1,66 mM. Dalam penentuan kadar nitrogen dioksida (NO2) pada udara digunakan larutan elektrolit NaClO4. Adapun konsentrasi masing-masing sampel secara berturut-turut adalah 0,28; 0,20 dan 0,16 ± 0,029 µg/m3. Berdasarkan hasil pengukuran didapat konsentrasi NO2 dari masingmasing lokasi masih di bawah standar baku mutu. Kata Kunci: pengembangan metode, analisis NO2 udara ambien, voltammetry square wave Abstract Analysis of ambient nitrogen dioxide (NO2) have done by using square wave voltammetry technique. NO2 was trapped in NaOH solution in impinger tool. The absorbed gas was converted to NO2- and analyzed by square wave voltammetry. The analysis use Au as working electrode, Pt as auxiliarly electrode and Ag/AgCl as reference electrode. H2SO4 0,3 M and NaClO4 0,1 M were used as supporting electrolytes. The scan rate was 100 mV/s. The result is potensial of standard electrode (Eo) ofNO2- in H2SO4 0,3 M is 800 mV, while NaClO4 0,1M is 1300 mV to Ag/AgCl. The curve calibrate NaNO2 with H2SO4 0,3M and NaClO4 0,1 M wich had correlation coefficient 0,992 and 0,956. Detection limits of this methode was 0,02 M and 1,66 mM. Because of the better fitness NaClO4 were used to analyze the sample. NO2 concentration for three sampling points were 0,28; 0,20 dan 0,16 ± 0,029 µg/m3 (still bellow the Indonesian National Ambient Air Quality Standard). Key words: method development, ambient NO2 analysis, square wave voltammetry
| Item Type: | Article |
|---|---|
| Subjects: | A General Works = Karya Karya Umum |
| Divisions: | Fakultas MIPA > Prodi Kimia |
| Depositing User: | IC-STAR . 2015 |
| Date Deposited: | 22 Oct 2015 08:50 |
| Last Modified: | 22 Oct 2015 08:50 |
| URI: | http://digilib.unila.ac.id/id/eprint/13183 |
Actions (login required)
![]() |
View Item |