0717011032, DWI PUJI ASTUTI (2012) Kajian Sebaran Logam Berat Cd dan Cr Pada Sedimen di Pesisir Pantai Way Kuala Bandar Lampung. Digital Library.
|
File PDF
ABSTRAK.pdf Download (6Kb) | Preview |
|
|
File PDF
BAB I.pdf Download (88Kb) | Preview |
|
|
File PDF
cover.compac[1].pdf Download (13Kb) | Preview |
|
|
File PDF
II.docx.fix.pdf Download (516Kb) | Preview |
|
|
File PDF
LEMBAR MENGESAHKAN.pdf Download (41Kb) | Preview |
|
|
File PDF
lembar pengesahan.pdf Download (18Kb) | Preview |
|
|
File PDF
Motto.pdf Download (20Kb) | Preview |
|
File PDF
Bab IV-.pdf Restricted to Hanya pengguna terdaftar Download (338Kb) |
||
|
File PDF
RIWAYAT HIDUP.docx.2.pdf Download (16Kb) | Preview |
|
|
File PDF
PERSEMBAHAN.pdf Download (32Kb) | Preview |
|
|
File PDF
SANWACANA.pdf Download (60Kb) | Preview |
|
|
File PDF
V.pdf Download (83Kb) | Preview |
|
|
File PDF
III.pdf Download (515Kb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
Abstrak Telah dilakukan kajian sebaran logam berat Cd dan Cr pada sedimen di muara sungai dan di pesisir pantai Way Kuala Bandar Lampung. Konsentrasi logam Cd dan Cr ditentukan dengan menggunakan spektofotometer serapan atom (SSA) dengan menggunakan dua validasi metode yaitu, presisi (ketelitian), dan linieritas. Hasil analisis menunjukkan konsentrasi logam Cd pada sedimen di muara sungai dan di pesisir pantai Way Kuala Bandar Lampung yaitu pada rentang 0 ppm sampai 0,2522 ± 0,011ppm. Konsentrasi logam berat Cr pada sampel sedimen di muara sungai dan di pesisir pantai Way Kuala Bandar Lampung yaitu pada rentang 1,243 ± 0,056 ppm sampai 1,361 ± 0,047 ppm. Validasi metode pada penentuan kadar Cd dan Cr pada sedimen menunjukkan presisi dengan nilai RSD < 5 %; koefisien korelasi untuk masing-masing logam Cd dan Cr adalah; 0,999 dan 0,995. Kata Kunci : Sebaran Logam, Cd, Cr, Way Kuala. Abstract This Study was carried out to insvestigate distribution of heavy metals Cd dan Cr in sediments of estuary and coastal region of Way Kuala Bandar lampung. Metals concentration were measured using Atomatic absorption spectroscopy (AAS), with two validation methods namely precision and linearity. The result obtained indicate that the concentration of Cd is in range of indetected 0 to 0,2522 ± 0,011ppm. While the concentration of Cr is in the range of 1,243 ± 0,056 ppm to 1,361 ± 0,047 ppm. The measurement was precision in term of RSD < 5%, with correlation coefficient of 0,999 to Cd and 0,995 to Cr. Keyword, : Way Kuala, Heavy metal, Cd, Cr, Precision, Linearity
Jenis Karya Akhir: | Artikel |
---|---|
Subyek: | |
Program Studi: | FAKULTAS MIPA > Prodi Kimia |
Pengguna Deposit: | IC-STAR . 2015 |
Date Deposited: | 20 Nov 2015 02:00 |
Terakhir diubah: | 20 Nov 2015 02:00 |
URI: | http://digilib.unila.ac.id/id/eprint/14486 |
Actions (login required)
Lihat Karya Akhir |