PENERAPAN MODEL BEBAN ZIP UNTUK ANALISA ALIRAN DAYA TIGA FASA PADA PENYULANG KATU GI MENGGALA

Gusmau Rado Pratama, 1115031041 (2016) PENERAPAN MODEL BEBAN ZIP UNTUK ANALISA ALIRAN DAYA TIGA FASA PADA PENYULANG KATU GI MENGGALA. Fakultas Teknik, Universitas Lampung.

[img]
Preview
File PDF
ABSTRAK INGGRIS DAN INDONESIA.pdf

Download (17Kb) | Preview
[img] File PDF
SKRIPSI FULL.pdf
Restricted to Hanya pengguna terdaftar

Download (88Mb)
[img]
Preview
File PDF
SKRIPSI TANPA PEMBAHASAN.pdf

Download (87Mb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

ABSTRAK PENERAPAN MODEL BEBAN ZIP UNTUK ANALISA ALIRAN DAYA TIGA FASA PADA PENYULANG KATU GI MENGGALA Oleh GUSMAU RADO PRATAMA Studi aliran daya sangat dibutuhkan untuk mendapatkan informasi mengenai aliran daya dan tegangan pada suatu sistem tenaga. Pada sistem distribusi, bus terdiri dari slack bus, PV Bus atau bus generator, dan PQ Bus atau bus beban. Setiap beban yang berbeda akan memberikan pengaruh yang berbeda juga terhadap sistem. Sehingga pada analisa aliran daya, beban dapat dimodelkan menjadi tiga jenis yaitu Constant Power (CP), Constant Current (CC), dan Constant Impedance (CI), atau biasa disebut dengan model beban ZIP. Oleh karena itu, dibuatlah simulasi aliran daya tiga fasa tak seimbang di jaringan distribusi (UnilaPF) yang menggunakan Metode Newton Raphson – rectangular dengan model beban ZIP. Kasus yang disimulasikan yaitu kasus Penyulang Katu GI Menggala dengan porsi model beban ZIP yang terdiri dari 100% CP, 100% CC, 100% CI, dan Mixed Load (30% CI, 30% CC, 40%CP). Hasil yang diperoleh oleh program UnilaPF kemudian dibandingkan dengan program OpenDSS, dan diperoleh hasil deviasi tegangan maksimal sebesar 1,2194% dengan total iterasi dari seluruh kasus sebanyak 10 iterasi pada UnilaPF dan 20 iterasi pada OpenDSS. Pemodelan beban ZIP yang disimulasikan memberikan hasil magnitude tegangan yang lebih tinggi dari beban yang seluruhnya constant power namun lebih rendah dari beban yang seluruhnya constant current dan constant impedance, dengan tegangan minimal sebesar 0.7091 pu. Kata Kunci : Aliran Daya, Newton Raphson – rectangular, Model Beban ZIP. ABSTRACT APPLICATION OF ZIP LOAD MODEL FOR THREE PHASE POWER FLOW ANALYSIS AT KATU FEEDER OF MENGGALA SUBSTATION By GUSMAU RADO PRATAMA Power flow studies are needed to obtain the information of power flow and voltage on a power system. In distribution system, the bus consists of slack bus, PV bus or generator bus, and PQ bus or load bus. Each different load will give different effect to the system. So that on the power flow analysis, the load can be modeled into three types, those are : Constant Power (CP), Constant Current (CC), and Constant Impedance (CI), or commonly called the ZIP load model. Therefore, the threephase power flow simulation in distribution system (UnilaPF) is made which uses the rectangular Newton - Raphson Method with ZIP load model. The simulated case is Katu feeder case with the portion of ZIP load model consists of 100% CP, 100% CC, 100% CI, and mixed load (30% CI, 30% CC, 40%CP). Then, the result of UnilaPF program is compared to OpenDSS program, and the result is the maximum voltage deviation of 1.2194% with total iterations of all cases are 10 iterations on UnilaPF and 20 iterations on OpenDSS. The ZIP load model which is simulated, provides higher voltage magnitude than the constant power load model but provides lower voltage magnitude than the constant current and constant impedance load model, with the minimum voltage magnitude of 0.7091 pu. Keywords : Power flow, Rectangular Newton Raphson, ZIP load model.

Jenis Karya Akhir: Skripsi
Subyek: > Teknik Elektro. Rekayasa elektronik Nuklir
> Teknik Elektro. Rekayasa elektronik Nuklir
Program Studi: Fakultas Teknik > Prodi S1-Teknik Elektro
Pengguna Deposit: 5847727 . Digilib
Date Deposited: 03 Mar 2016 07:29
Terakhir diubah: 03 Mar 2016 07:29
URI: http://digilib.unila.ac.id/id/eprint/21424

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir