PENENTUAN KAPASITAS DAN PENEMPATAN BANYAK KAPASITOR PARALEL PADA PENYULANG BADAI DI GI TELUK BETUNG MENGGUNAKAN PERHITUNGAN ARUS REAKTIF

BRILLIAN UNGGUL WICAKSONO , 0915031027 (2016) PENENTUAN KAPASITAS DAN PENEMPATAN BANYAK KAPASITOR PARALEL PADA PENYULANG BADAI DI GI TELUK BETUNG MENGGUNAKAN PERHITUNGAN ARUS REAKTIF. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
ABSTRAK (ABSTRACT).pdf

Download (9Kb) | Preview
[img] File PDF
SKRIPSI FULL.pdf
Restricted to Hanya pengguna terdaftar

Download (2893Kb)
[img]
Preview
File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf

Download (2026Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

ABSTRAK Kapasitor adalah peralatan listrik yang dapat menghasilkan daya reaktif yang diperlukan oleh beban sehingga aliran daya reaktif di saluran dapat berkurang dengan kata lain kapasitor bermanfaat menaikkan faktor daya, memperbaiki profil tegangan serta mengurangi rugi-rugi. Penempatan kapasitor dengan kapasitas kapasitor yang berdasarkan arus beban dapat memimisasi rugi-rugi dan perbaikan profil tegangan. Skripsi ini bertujuan menentukankapasitas dan penempatan lokasi banyak kapasitor paralel dengan menggunakan perhitungan arus reaktif.Studi kasus ini dilakukan pada penyulang Badai GI Teluk Betung dan analisis aliran daya menggunakan software MATPOWER 4.2. Dari hasil simulasi dapat disimpulkan bahwa dengan pemasangan kapasitor paralel pada sistem distribusi di penyulang Badai di GI Teluk Betung dapat mengurangi rugi-rugi total daya aktif dan reaktif. Sebelum pemasangan kapasitor didapat rugi-rugi daya aktif total sebesar 211,690 kW dan daya reaktif total sebesar 190,457 kVAR. Hasil simulasi menunjukkan bahwa penempatan optimal banyak kapasitor paralel adalah pada bus 43 dan 2. Setelah penempatan dua kapasitor diperoleh rugi-rugi daya aktif sebesar 163,025 kW dengan presentase pengurangan 22,99% dan rugi-rugi daya reaktif total sebesar 146,873 kVAR dengan presentase sebesar 22,88%. Kata kunci : kapasitor paralel, perhitungan arus reaktif, rugi-rugi daya, GI Teluk Betung. ABSTRACT Capacitors are electrical equipment that can generate reactive power required by the load so that the reactive power flow in the line can be reduced, in other words capacitors are useful to increase power factor, improve voltage profile and reduce losses. Placement of the capacitors with its capacity based on the current load can minimize losses and improve voltage profile. This thesis aims to determine the capacity and the placement location of many capacitor parallel by using reactive current calculation. This case study is conducted on Badai feeder in Teluk Betung substation and power flow analysis is performed using MATPOWER 4.2 software. From the simulation results can be concluded that with the placement of parallel capasitors on distribution system in Badai feeder in Teluk Betung substation can reduce the total active power losses and total reactive power losses. Before placement the capacitors, the active power losses obtained is 211,690 kW and the total reactive power losses is 190,457 kVAR. The simulation results showed that the optimal placements of many parallel capacitors are on bus 43 and bus 2. After placing two capacitors the total active power losses obtained is 163,025 kW or percentage of reduction is 22,99% and a reduction of the total reactive power losses is 146,873 kVAR with a percentage of 22,88%. Keywords : parallel capacitor, reactive current calculation, power losses, GI Teluk Betung.

Jenis Karya Akhir: Skripsi
Subyek: > Teknik Elektro. Rekayasa elektronik Nuklir
> Teknik Elektro. Rekayasa elektronik Nuklir
Program Studi: Fakultas Teknik > Prodi S1-Teknik Elektro
Pengguna Deposit: 9815803 . Digilib
Date Deposited: 23 Aug 2016 03:48
Terakhir diubah: 23 Aug 2016 03:48
URI: http://digilib.unila.ac.id/id/eprint/23541

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir