MUHAMMAD ISMATULLAH, 1515031022 (2019) ENERGY HARVESTING DARI COMPACT FLUORESCENT LAMP (CFL) MENGGUNAKAN FLAT WOUND PLANAR COIL. Fakultas Teknik, UNIVERSITAS LAMPUNG.
|
File PDF
ABSTRAK-ABSTRACT.pdf Download (248Kb) | Preview |
|
File PDF
SKRIPSI FULL.pdf Restricted to Hanya staf Download (4Mb) |
||
|
File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf Download (4Mb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
Lampu compact fluorescent lamp (CFL) merupakan jenis lampu yang sering digunakan sebagai penerangan. Lampu CFL memancarkan radiasi elektromagnetik dari komponen elektroniknya (ballast). Penelitian ini mengusulkan pemanfaatan radiasi elektromagnetik dari lampu CFL menggunakan konsep energy harvesting. Konsep yang digunakan sebagai transfer energi dari radiasi lampu CFL adalah kopling resonansi magnetik. Daya yang diperoleh dari alat pemanen (harvester) adalah daya AC. Daya AC disearahkan oleh rectifier sehingga dihasilkan daya DC. Daya DC digunakan untuk mengisi muatan (charging) super kapasitor. Super kapasitor digunakan sebagai pengganti catu daya peralatan elektronik berdaya rendah seperti sensor. Perancangan alat pada penelitian ini menggunakan penangkap (harvester) berupa flat wound planar coil yang dirancang menggunakan kawat tembaga 0,5mm. Flat wound planar coil berfungsi sebagai harvester untuk menangkap radiasi elektromagnetik dan mengubahnya menjadi tegangan AC frekuensi tinggi menggunakan prinsip kopling resonansi magnetik. Tegangan AC disearahkan menggunakan penyearah (rectifier) susunan Dickson 3 stage dan 2 stage menjadi tegangan DC. Tegangan DC hasil penyerahan digunakan untuk pengisian muatan (charging) super kapasitor 2,7V/10F. Berdasarkan pengujian yang dilakukan, radiasi yang ditangkap oleh flat wound planar coil berupa daya AC yang diperoleh sebesar 42,03mW pada lampu CFL 45Watt dan 0,34mW pada lampu CFL 20Watt. Penyearah susunan Dickson 3 stage memiliki efisiensi lebih tinggi dibanding dengan susunan Dickson 2 stage. Susunan Dickson 3 mampu menyearahkan daya AC 42,03mW menjadi daya DC 16,54mW, sedangkan penyearah susunan Dickson 2 stage menyerahkan daya AC 42,03mW menjadi daya DC 13,99mW. Waktu pengisian (charging time) super kapasitor selama 9jam menggunakan penyearah susunan Dickson 3 stage dan 9,5jam menggunakan penyearah susunan Dickson 2 stage dengan tegangan maksimum 2,7V. Untuk memperoleh tegangan 3,3V (sesuai tegangan catu daya sensor) dibutuhkan dua buah super kapasitor yang diseri dengan charging time selama 5 jam menggunakan penyearah susunan Dickson 3 stage dan 8 jam menggunakan penyearah susunan Dickson 2 stage. Kata Kunci: Energy harvesting, compact fluorescent lamp, kopling resonansi magnetik, rectifier, super kapasitor. Compact fluorescent lamp (CFL) is a type of lamp that is often used as lighting. CFL lamps emit electromagnetic radiation from electronic components (ballast). This study proposed use electromagnetic radiation from CFL lamps using energy harvesting concept. The concept used as energy transfer from CFL lamp radiation is magnetic resonance coupling. The power obtained from a harvester is AC power. AC power is converted to DC power using rectifier. DC power is used to charged super capacitors. Super capacitor is used as supply for low-power electronic equipment such as sensors. This study design flat wound planar coil as harvester and designed using 0.5mm copper wire. The function of flat wound planar coil is to captured electromagnetic radiation and converted into high frequency AC voltage using the principle of magnetic resonance coupling. The AC voltage is converted to DC voltage using a 3 stages and 2 stages Dickson rectifier. The DC voltage is used for charging 2.7V/10F super capacitor. The result of the test showed that the radiation captured by the flat wound planar coil are AC power 42.03mW at 45Watt CFL lamps and 0.34mW at 20Watt CFL lamps. The 3 stage Dickson rectifier has higher efficiency compared with 2 stage Dickson rectifier. The 3 stage Dickson rectifier converted 42.03mW AC power to 16.54mW DC power and the 2 stage Dickson rectifier converted 42.03mW AC power to 13.99mW DC power. Charging time super capacitors are 9 hours using 3 stage Dickson rectifier and 9.5 hours using a 2 stage Dickson rectifier with a maximum voltage 2.7V. To get 3.3V voltage (according sensor power supply voltage) used 2 super capacitors with charging time 5 hours using a 3 stage Dickson rectifier and 8 hours using 2 stage Dickson rectifier. Keywords: Energy harvesting, compact fluorescent lamp, magnetic resonance coupling, rectifier, super capacitor.
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | 600 Teknologi (ilmu terapan) 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan |
Program Studi: | Fakultas Teknik > Prodi S1-Teknik Elektro |
Pengguna Deposit: | UPT . Digilib2 |
Date Deposited: | 29 Mar 2022 13:22 |
Terakhir diubah: | 29 Mar 2022 13:22 |
URI: | http://digilib.unila.ac.id/id/eprint/56627 |
Actions (login required)
Lihat Karya Akhir |