PENGARUH VARIASI SUHU PADA EKSTRAKSI TiO2 DALAM PASIR BESI LAMPUNG MENGGUNAKAN METODE PELINDIAN HCl

Anggi Stevani, 1717041030 (2021) PENGARUH VARIASI SUHU PADA EKSTRAKSI TiO2 DALAM PASIR BESI LAMPUNG MENGGUNAKAN METODE PELINDIAN HCl. Fakultas Teknik, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
1. ABSTRAK - ALLIF Printing (2).pdf

Download (92Kb) | Preview
[img] File PDF
2. SKRIPSI FULL - ALLIF Printing (2).pdf
Restricted to Hanya staf

Download (3653Kb)
[img]
Preview
File PDF
3. SKRIPSI FULL TANPA BAB PEMBAHASAN - ALLIF Printing (2).pdf

Download (2678Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Telah dilakukan penelitian untuk mengetahui pengaruh variasi suhu pada ekstraksi TiO2 dalam pasir besi Lampung menggunakan metode pelindian HCl. Bahan baku yang digunakan adalah pasir besi yang berasal dari pantai Pesisir Barat Lampung. Bahan baku yang telah lolos ayakan 200 mesh dicampur dengan NaHCO3 kemudian dipanaskan pada suhu 700 oC selama 1 jam. Variasi suhu pelindian yang digunakan yaitu 70, 80, 90, 100 dan 110 oC dengan konsentrasi larutan HCl 12 M dan waktu pelindian selama 2 jam. Hasil data X-Ray Fluorescence (XRF) menunjukkan bahwa kandungan TiO2 pada sampel mengalami peningkatan siginifikan pada suhu pelindian 110o C, yaitu dari 13,808% menjadi 60,701%. Hasil data X-Ray Diffraction (XRD) menunjukan bahwa fasa yang TiO2 terbentuk pada sampel yaitu anatase, brukit dan rutil. Hasil analisis SEM-EDS menunjukkan bahwa morfologi permukaan sampel berbentuk butiran yang tidak seragam dan komposisi Ti sebesar 0,12%. Kata kunci: Pasir besi, pelindian,suhu, TiO2. Research has been done to know the effect of temperature variations on the extraction of TiO2 in iron sand Lampung using the HCl leaching method. The raw material is iron sand from the West Coast of Lampung. The raw materials that have passed the 200 mesh sieve were mixed with NaHCO3 and then heated at a roasting temperature of 700 oC for 1 hour. The leaching temperature variations were 70, 80, 90, 100 and 110 oC with a concentration of HCl 12 M solution and a leaching time of 2 hours. The results of X-Ray Fluorescence (XRF) data shows that the TiO2 content in the sample has a significant increase at the leaching temperature of 110 oC, from 13,808% to 60,701%. The results of the X-Ray Diffraction (XRD) data shows that the phases that TiO2 formed in the sample are anatase, brookite and rutile. The results of the SEM-EDS analysis shows that the surface morphology of the sample is in the form of non-uniform grains and the Ti composition is 0,12%. Keywords: Irond sand, leacing, TiO2, temperature.

Jenis Karya Akhir: Skripsi
Subyek: 500 ilmu pengetahuan alam dan matematika
500 ilmu pengetahuan alam dan matematika > 510 Matematika
Program Studi: FAKULTAS MIPA > Prodi Matematika
Pengguna Deposit: UPT . Dito Nipati
Date Deposited: 27 Apr 2022 02:20
Terakhir diubah: 27 Apr 2022 02:20
URI: http://digilib.unila.ac.id/id/eprint/60554

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir