RISA KURNIAWATI, 1715011008 (2021) EVALUASI KINERJA STRUKTUR GEDUNG BERTINGKAT MENGGUNAKAN NON LINEAR STATIC PUSHOVER ANALYSIS DENGAN CAPACITY SPECTRUM METHOD (CSM) (Studi Kasus: Gedung B Rumah Sakit Umum Muhammadyah Metro). FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.
|
File PDF
1. ABSTRAK RISA - Risa Kurniawati.pdf Download (251Kb) | Preview |
|
File PDF
2. SKRIPSI LENGKAP RISA TANPA LAMPIRAN-RISA.pdf Restricted to Hanya staf Download (5Mb) |
||
|
File PDF
3. SKRIPSI RISA TANPA PEMBAHASAN-RISA.pdf Download (4Mb) | Preview |
Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)
Indonesia merupakan wilayah rawan gempa bumi. Salah satu upaya untuk mengantisipasi dampak bencana gempa bumi adalah dengan memenuhi kebutuhan akan bangunan tahan gempa. Untuk menjaga keselamatan penghuninya, bangunan harus memberikan kinerja yang optimal. Maka dari itu, diperlukan suatu analisis gaya gempa dalam hal ini analisis pushover. Analisis pushover adalah suatu analisis dimana pengaruh gempa rencana pada struktur dianggap sebagai beban statik yang menangkap pada pusat massa masing-masing lantai. Penelitian ini mengambil studi kasus pada Gedung B Rumah Sakit Umum Muhammadyah Metro. Penelitian ini bertujuan untuk mengetahui performance point dan kriteria level kinerja gedung menggunakan analisis pushover dengan capacity spectrum method (CSM). Adapun peraturan standar yang digunakan pada penelitian ini antara lain SNI 1727-2020, SNI 1726-2019, FEMA-440 (2005), serta ATC-40 (1996). Berdasarkan hasil penelitian disimpulkan bahwa Gedung menunjukkan kinerja damage control jika dilihat dari data perencanaan dengan konsep struktur ideal. Namun, struktur gedung ini pada kondisi eksisting tidak memenuhi konsep keruntuhan ideal. Dengan demikian. apabila terjadi gempa, perilaku daktail parsial pada gedung mengakibatkan kerusakan struktur tetapi tidak runtuh. Gempa tersebut memiliki masa layan selama umur struktur bangunan 50 tahun adalah 10%. Kata kunci: Analisis pushover, Gempa, Level Kinerja Indonesia is an earthquake prone area. One of the efforts to anticipate the impact of an earthquake is to meet the need for earthquake-resistant buildings. To maintain the safety of its occupants, buildings must provide optimal performance. Therefore, an earthquake force analysis is needed in this case a pushover analysis. Pushover analysis is an analysis where the influence of the design earthquake on the structure is considered as a static load that captures the center of mass of each floor. This research takes a case study in The B Building of Muhammadyah Metro General Hospital. The purpose of this study to determine the performance point and building performance level using pushover analysis with the capacity spectrum method (CSM). The standard provisions used in this study refer to SNI 1727-2020, SNI 1726-2019, FEMA-440 (2005), and ATC-40 (1996). Based on the results, it can be concluded that this Building shows performance with a level of damage control when viewed from the planning data with the concept of an ideal structure. However, the structure of this building in the existing condition doesn’t meet the ideal collapse concept. Therefore. in the event of an earthquake, the partial ductile behavior of the building results in structural damage but doesn’t collapse. The earthquake has a probability of being exceeded during the life of the structure of 50 years is 10%. Keywords: Pushover Analysis, Earthquake, Performance Level
Jenis Karya Akhir: | Skripsi |
---|---|
Subyek: | 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan |
Program Studi: | Fakultas Teknik > Prodi S1-Teknik Sipil |
Pengguna Deposit: | UPT . Neti Yuliawati |
Date Deposited: | 27 May 2022 03:11 |
Terakhir diubah: | 27 May 2022 03:11 |
URI: | http://digilib.unila.ac.id/id/eprint/61846 |
Actions (login required)
Lihat Karya Akhir |