HUBUNGAN NILAI CBR LABORATORIUM DENGAN PEMADATAN MODIFIED DAN NILAI DYNAMIC CONE PENETROMETER (DCP) DI LAPANGAN

RIANT PANDU PRATOMO, 1415011125 (2021) HUBUNGAN NILAI CBR LABORATORIUM DENGAN PEMADATAN MODIFIED DAN NILAI DYNAMIC CONE PENETROMETER (DCP) DI LAPANGAN. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
1.ABSTRAK - pandu riant.pdf

Download (96Kb) | Preview
[img] File PDF
2.SKRIPSI FULL - pandu riant.pdf
Restricted to Hanya staf

Download (4Mb)
[img]
Preview
File PDF
3.SKRIPSI TANPA BAB PEMBAHASAN - pandu riant.pdf

Download (4091Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Tanah merupakan salah satu bagian penting dalam pekerjaan konstruksi teknik sipil. Kekuatan tanah dasar sangat penting guna menopang beban konstruksi. Salah satu cara untuk mengetahui nilai CBR adalah melakukan pengujian CBR di laboratorium dengan sampel tanah yang diambil dari lapangan. Namun pada kenyataannya di lapangan, banyak kendala yang dihadapi maka seringkali dilakukan uji DCP (Dynamic Cone Penetrometer). Penelitian ini menghasilkan persamaan hubungan antara CBR laboratorium dan DCP serta perbandingannya dengan persamaan SNI. Hasil dari penelitian ini didapatkan dengan menguji tanah di Teluk Ratai Kabupaten Pesawaran pada tiga titik. Pengujian yang dilakukan meliputi uji CBR laboratorium (Unsoaked), uji DCP mould, uji DCP lapangan dan uji sand cone. Sampel tanah dipadatkan dengan variasi pemadatan 10, 25, dan 56 tumbukan dan kadar air optimum sebesar 22,95% yang didapat dari uji pemadatan dengan proctor modified. Hasil penelitian menunjukkan persamaan korelasi CBR laboratorium dengan γd adalah y = 30,878x – 26,98 dan korelasi persamaan CBR dan DCP didapatkan Log (CBR) = 2,26557 – 0,807 Log (DCP). Bila dibandingkan, nilai CBR dari persamaan CBR dan DCP memiliki nilai yang lebih tinggi daripada nilai CBR dengan menggunakan persamaan SNI. . Kata kunci : Tanah, Sand Cone, Daya Dukung, CBR Laboratorium, DCP Lapangan. Soil is one of the important parts in civil engineering work. The shear strength of the soil is essential to sustain the load. One of the ways to find out the CBR value is CBR testing in a laboratory with soil samples derived from the field. In the other hand, the fact is there are some difficulties, so that DCP is performed. This research is conducted to find out the relationship between CBR laboratory and DCP, and also the comparison based on SNI equations. The result was obtained by testing the soil in three areas at Teluk Ratai Kabupaten Pesawaran. The tests included CBR Laboratory test (unsoaked), DCP mould test, DCP on the field test and sand cone test. Furthermore, the soil samples were compacted under the compaction variations of 10, 25 and 56, and the optimum water content is 22,95%, and followed by modified proctor test. The result exhibited the correlations between CBR laboratory with dry density is y=30,878x – 26,98 and correlation CBR and DCP with logarithmic correlation equation is Log (CBR) = 2,26557 – 0,807 Log (DCP). From the correlation equation, the CBR value from laboratory test is better than CBR from SNI. Keywords: soil, sand cone, bearing capacity, CBR Laboratories, DCP.

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: Fakultas Teknik > Prodi S1-Teknik Sipil
Pengguna Deposit: UPT . Meda Sulistiana
Date Deposited: 27 May 2022 07:22
Terakhir diubah: 27 May 2022 07:22
URI: http://digilib.unila.ac.id/id/eprint/61910