ANALISIS HEAT BALANCE PADA REAKTOR TOREFAKSI TIPE TUBULAR DENGAN SISTEM PEMANAS OIL JACKET

ZULKRI KURNIAWANSAH, 1815021008 (2022) ANALISIS HEAT BALANCE PADA REAKTOR TOREFAKSI TIPE TUBULAR DENGAN SISTEM PEMANAS OIL JACKET. FAKULTAS TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
ABSTRAK.pdf

Download (2869Kb) | Preview
[img] File PDF
SKRIPSI FULL.pdf
Restricted to Hanya staf

Download (2868Kb)
[img]
Preview
File PDF
SKRIPSI TANPA BAB PEMBAHASAN.pdf

Download (2870Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

ABSTRAK ANALISIS HEAT BALANCE PADA REAKTOR TOREFAKSI TIPE TUBULAR DENGAN SISTEM PEMANAS OIL JACKET Oleh Zulkri Kurniawansah Torefaksi merupakan salah satu metode pengolahan biomassa melalui proses termal menjadi bahan bakar bakar padat berkualitas setara batubara subbituminus. Salah satu jenis reaktor kontinu yang sedang dikembangkan adalah reaktor torefaksi tipe tubular. Reaktor tipe tubular memiliki mekanisme pembakaran secara langsung menggunakan energi yang bersumber dari LPG dan dirancang menggunakan pemanas jenis oil jacket heater. Penelitian tentang heat balance ini mempunyai tujuan untuk mengukur tingkat efektivitas energi yang nantinya dapat digunakan untuk mengetahui berapa besar energi yang diterima dan heat loss yang terjadi selama proses pengujian. Sampel yang digunakan untuk proses pengujian adalah jenis sampel Albizia Chinensis dalam bentuk chip. Dalam proses pengujian tahap pertama dilakukan pemanasan reaktor selama 85 menit, kemudian ketika temperatur reaktor dan oli sudah dalam keadaaan steady dengan temperatur berada pada 275°C sampel pengujian mulai dimasukkan kedalam reaktor. Proses pengujian sampel didalam reaktor sampai dengan keluarnya hasil sampel torefaksi terjadi selama 65 menit. Dari data temperatur ini selanjutnya dihitung nilai energi dari seperti berapa energi diberikan untuk produk torefaksi, berapa energi yang diterima untuk produk tertorefaksi dan berapa nilai heat loss yang terjadi selama proses torefaksi berlangsung. Dari perhitungan ini didapatkan hasil dari energi masuk yang terjadi sebesar 125.257 kJ (100%), energi diterima sebesar 30.113 kJ (4,61%) dan heat loss sebesar 95.145 kJ (75,96%). Selama proses pengujian berlangsung didapatkan nilai heat loss sebesar 75,96% sehingga berpotensi untuk dimanfaatkan contohnya seperti mengurangi kadar air pada sampel yang masih basah. Kata kunci : torefaksi, reaktor tubular, heat loss. ABSTRACT HEAT BALANCE ANALYSIS ON TUBULAR TYPE OF TOREFACTION REACTOR WITH OIL JACKET HEATING SYSTEM By Zulkri Kurniawansah Torrefaction is a method of processing biomass through a thermal process into solid fuel quality equivalent to sub-bituminous coal. One type of continuous reactor being developed is a tubular type torrefaction reactor. The tubular type reactor has a direct combustion mechanism using energy sourced from LPG and is designed to use an oil jacket heater. This research on heat balance has the aim of measuring the level of energy effectiveness which can later be used to find out how much energy is received and the heat loss that occurs during the testing process. The sample used for the testing process is a type of Albizia Chinensis sample in the form of a chip. In the first stage of the testing process, the reactor was warmed up for 85 minutes, then when the reactor temperature and oil were in a steady state with a temperature of 275°C the test sample was introduced into the reactor. The process of testing the sample in the reactor until the results of the torrefaction sample are released takes 65 minutes. From this temperature data, the energy value is calculated, such as how much energy is given to the torrefaction product, how much energy is received for the torrefaction product and how much heat loss occurs during the torrefaction process. From this calculation, it is obtained that the incoming energy is 125.257 kJ (100%), the received energy is 30.113 kJ (4.61%) and the heat loss is 95.145 kJ (75.96%). During the testing process, a heat loss value of 75.96% was obtained so that it has the potential to be used, for example, to reduce the water content in samples that are still wet. Keywords: torrefaction, tubular reactor, heat loss. Keywords: torrefaction, tubular reactor, heat loss

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: Fakultas Teknik > Prodi S1-Teknik Mesin
Pengguna Deposit: 2208232596 . Digilib
Date Deposited: 24 Aug 2022 14:05
Terakhir diubah: 24 Aug 2022 14:05
URI: http://digilib.unila.ac.id/id/eprint/65679

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir