ANALISIS PERBANDINGAN KERENTANAN BANGUNAN GEDUNG BERDASARKAN DATA MIKROTREMOR SIANG DAN MALAM

Vivi , Anita Sari (2024) ANALISIS PERBANDINGAN KERENTANAN BANGUNAN GEDUNG BERDASARKAN DATA MIKROTREMOR SIANG DAN MALAM. TEKNIK, UNIVERSITAS LAMPUNG.

[img]
Preview
File PDF
ABSTRAK - Vivi Anita Sari.pdf

Download (130Kb) | Preview
[img] File PDF
SKRIPSI FULL - Vivi Anita Sari.pdf
Restricted to Hanya staf

Download (1958Kb) | Minta salinan
[img]
Preview
File PDF
SKRIPSI TANPA BAB PEMBAHASAN - Vivi Anita Sari.pdf

Download (1719Kb) | Preview

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Telah dilakukan penelitian mengenai analisa tingkat kerentanan bangunan BMKG Wilayah III Denpasar Bali pada waktu siang dan malam hari yang berdasarkan dari pengolahan data mikrotremor menggunakan metode Horizontal to Vertical Spectral Ratio HVSR untuk mendapatka nilai frekuensi natural tanah dan Floor Spectral Ratio FSR untuk mendapatka nilai frekuensi natural bangunan, nilai frekuensi digunakan untuk melakukan analisis resonansi dan indeks kerentanan pada tanah dan bangunan. Data mikrotremor yang digunakan merupakan data pengukuran menggunakan alat accelometer dengan empat titik pengukuran dengan tiga titik pada gedung yang terletak di lantai 1, 2 dan 3, serta satu pada lubag bor diluar gedung, dengan waktu pengukuran pada siang hari pukul 12.00 – 15.00 WITA dan pada malam hari pukul 00.00 – 03.00 WITA. Dari penelitian tersebut didapatkan nilai frekuensi tanah pada siang hari lebih besar yaitu 3,15 hz dan malam hari 1,63 hz, frekuensi bagunan pada siang hari didapatkan nilai yang lebih kecil daripada malam hari yaitu dengan rentang 0,57 – 1,22 hz dan malam hari dengan rentang nilai 0,72 – 1,58 hz. Tingkat resonansi yang didapatkan pada siang hari lebih tinggi yaitu berkisar antara 61% - 84% dan malam harinya didapatkan 40% - 73%. Untuk tingkat kerentanan tanah didapatkan 0,97 pada siag hari dan 1,33 pada malam hari yang tergolong dalam resiko rendah, untuk tingkat kerentanan bagunan berkisar 0,46 – 3,82 pada siag hari dan 0,18 – 2,09 pada malam hari. Kata kunci : Mikrotremor, HVSR, FSR, Gempa bumi Research has been carried out regarding the level of vulnerability of BMKG Region III Denpasar Bali buildings during the day and night based on microtremor data using the Horizontal to Vertical Spectral Ratio (HVSR) method for soil and Floor Spectral Ratio (FSR) for buildings, from the processing the dominant frequency value was obtained to carry out resonance analysis and vulnerability indices on soil and buildings. The microtremor data used is measurement data using an accelometer with four measurement points with three points on the building, namely on the 1st, 2nd and 3rd floors, as well as one point in the drill hole outside the building, with measurement times during the day at 12.00 - 15.00 WITA and at evening 00.00 – 03.00 WITA. From this research, it was found that the ground frequency value was greater during the day, namely 3.15 Hz and 1.63 Hz at night, the building frequency during the day was found to be a smaller value, namely with a range of 0.57 – 1.22 Hz and at night with a value range of 0, 72 – 1.58 Hz. The resonance level obtained during the day is higher, ranging from 61% - 84% and at night it is found at 40% - 73%. For the level of soil vulnerability during the day, it was found to be 0.97 and at night 1.33 which was classified as low risk, for the level of building vulnerability it was around 0.46 – 3.82 during the day and 0.18 – 2.09 at night. Keyword : Microtremors, HVSR, FSR, Earthquakes

Jenis Karya Akhir: Skripsi
Subyek: 600 Teknologi (ilmu terapan) > 620 Ilmu teknik dan ilmu yang berkaitan
Program Studi: FAKULTAS TEKNIK (FT) > Prodi S1-Teknik Geofisika
Pengguna Deposit: . . Yulianti
Date Deposited: 14 May 2025 04:58
Terakhir diubah: 14 May 2025 04:58
URI: http://digilib.unila.ac.id/id/eprint/87045

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir