OPTIMASI KUAT TEKAN DAN DAYA SERAP AIR DARI PEMBUATAN BATA BETON DENGAN PEMANFAATAN ABU DASAR (BOTTOM ASH) (OPTIMIZATION OF COMPRESSIVE AND WATER ABSORTION STRENGTH OF THE CONCRETE BRICK WITH THE UTILIZATION OF BOTTOM ASH)

Suprapto, AYU AGUNG PUSPITASARI (2013) OPTIMASI KUAT TEKAN DAN DAYA SERAP AIR DARI PEMBUATAN BATA BETON DENGAN PEMANFAATAN ABU DASAR (BOTTOM ASH) (OPTIMIZATION OF COMPRESSIVE AND WATER ABSORTION STRENGTH OF THE CONCRETE BRICK WITH THE UTILIZATION OF BOTTOM ASH). Fakultas Teknik, Universitas Lampung.

[img]
Preview
File PDF
COVER DALAM.pdf - Published Version

Download (9Kb) | Preview
[img]
Preview
File PDF
ABSTRAK INDONESIA.pdf - Published Version

Download (83Kb) | Preview
[img]
Preview
File PDF
ABSTRACT INGGRIS.pdf - Published Version

Download (8Kb) | Preview
[img]
Preview
File PDF
HALAMAN PERSETUJUAN.pdf - Published Version

Download (181Kb) | Preview
[img]
Preview
File PDF
HALAMAN PERNYATAAN.pdf - Published Version

Download (137Kb) | Preview
[img]
Preview
File PDF
DAFTAR ISI.pdf - Published Version

Download (14Kb) | Preview
[img]
Preview
File PDF
BAB I.pdf - Published Version

Download (92Kb) | Preview
[img]
Preview
File PDF
BAB II.pdf - Published Version

Download (288Kb) | Preview
[img]
Preview
File PDF
BAB III.pdf - Published Version

Download (416Kb) | Preview
[img] File PDF
BAB IV.pdf - Published Version
Restricted to Hanya pengguna terdaftar

Download (498Kb)
[img]
Preview
File PDF
BAB V.pdf - Published Version

Download (86Kb) | Preview
[img]
Preview
File PDF
DAFTAR PUSTAKA.pdf - Published Version

Download (50Kb) | Preview
[img] Archive
LAMPIRAN.zip - Published Version

Download (6Mb)

Abstrak (Berisi Bastraknya saja, Judul dan Nama Tidak Boleh di Masukan)

Pemakaian batubara sebagai sumber energi pada pembangkit listrik ataupun industri lainnya mengakibatkan timbulnya limbah padat, yaitu berupa fly ash (abu terbang) dan bottom ash (abu dasar). Salah satu cara pemanfaatan limbah batubara adalah dengan memanfaatkannya sebagai bahan bangunan. Pada penelitian ini, limbah batubara (bottom ash) dimanfaatkan sebagai bahan pengganti sebagian pasir pada bahan bangunan berupa bata beton berlubang. Penelitian ini bertujuan untuk mengetahui pengaruh dari pemanfaatan bottom ash dalam bata beton berlubang terhadap kuat tekan dan daya serap air bata beton berlubang, serta mengetahui persentase optimum bottom ash dalam pencampuran bata beton berlubang. Perbandingan komposisi campuran antara semen dan pasir yang digunakan adalah 1 : 5, sedangkan variasi penggunaan bottom ash yang digunakan dalam campuran adalah sebesar 0%, 5%, 10%, 15%, 20%, 25% dan 30% dari berat pasir. Hasil penelitian menunjukkan bahwa bata beton berlubang dengan komposisi bottom ash dalam campuran sebesar 25% dari berat pasir, menghasilkan kuat tekan optimum, yakni 45,46 kg/cm² untuk umur 28 hari dan 48,58 kg/cm² untuk umur 56 hari. Kedua bata beton berlubang tersebut masuk dalam kelas mutu II SNI 03-0349-1989. Untuk hasil uji penyerapan air, menunjukkan bahwa penyerapan air bata beton berlubang masuk ke dalam mutu II SNI 03-0349-1989, besar kecilnya penyerapan air dipengaruhi oleh nilai kuat tekan bata beton berlubang. Kata kunci : bata beton berlubang, bottom ash, kuat tekan, daya serap air (The use of coal as an energy source in power plants or other industries might result emerge of solid waste, in the form of fly ash and bottom ash. One way to utilize the use of coal waste is by using it as building material. In this study, coal waste (bottom ash) is used as a partial replacement of sand in construction materials such as hollow bricks. This study aimed to determine the effect of the utilization of bottom ash in hollow brick toward the compressive and water absorption strength of hollow brick, as well as to determine the optimum percentage of bottom ash in the mixing of hollow brick. The comparison of the mixture composition of cement and sand used is 1: 5, whereas variations in the usage of bottom ash used in the mixture is at 0%, 5%, 10%, 15%, 20%, 25% and 30% of the weight of the sand. The results showed that the hollow brick in a mixture with 25% bottom ash composition of the weight of the sand, produce the optimum compressive strength, 45.46 kg / cm ² for 28 days old and 48.58 kg / cm ² for 56 days old. Both of the hollow brick can be classified into the class II of SNI 03-0349-1989. For the water absorption test results, showed that the water absorption strength of Hollow brick can be classified into the class II of SNI 03-0349-1989, the amount of the water absorption strength is affected by the compressive strength of hollow brick. Key words: hollow brick, bottom ash, compressive strength, water absorption strength.)

Jenis Karya Akhir: Skripsi
Subyek: > Teknologi (General)
> Teknologi (General)
Teknologi (General)

> Mesin (General). Mesin Sipil (General)
> Mesin (General). Mesin Sipil (General)
Mesin (General). Mesin Sipil (General)
Program Studi: Fakultas Teknik > Prodi Magister Teknik Sipil
Pengguna Deposit: UPT Perpustakaan Unila
Date Deposited: 16 Jan 2014 07:33
Terakhir diubah: 16 Jan 2014 07:33
URI: http://digilib.unila.ac.id/id/eprint/505

Actions (login required)

Lihat Karya Akhir Lihat Karya Akhir